# Vertiv Liebert DataMate3000-2 DME22 Computer Room Precision Air Conditioner 22kW (22kW Downflow EC Fans)

RICEWIND · Vertiv

https://ricewind.com/en/products/liebert-datamate3000-2

Model: Liebert DataMate3000-2 DME22

Vertiv Liebert DataMate3000-2 DME22 is a next-generation 22kW room-level precision air conditioner featuring an 800x765x1975mm compact footprint, 7-inch HMI touchscreen, and eco-friendly R410A refrigerant.

## What this product is

Vertiv Liebert DataMate3000-2 DME22 is a next-generation 22kW room-level precision air conditioner featuring an 800x765x1975mm compact footprint, 7-inch HMI touchscreen, and eco-friendly R410A refrigerant.

## What problem it solves

Vertiv Liebert DataMate3000-2 DME22 delivers 22kW continuous cooling with AI self-diagnostic controls and high sensible heat ratio for telecom shelters and substation equipment rooms.

## Who and where it is for

Vertiv Liebert DataMate3000-2 DME22 is a next-generation 22kW room-level precision air conditioner featuring an 800x765x1975mm compact footprint, 7-inch HMI touchscreen, and eco-friendly R410A refrigerant.

## Core advantages

- 22kW compact high-capacity cooling chassis
- 7-inch full-color HMI touch screen
- AI self-learning and fault self-diagnosis
- Quick-connect fitting for weld-free installation

## Applications

- Hyperscale and enterprise cloud data center high-density server halls and aisle containment
- Telecommunications switching centers, optical transmission rooms, and carrier core facilities
- High-reliability industrial test laboratories and clean room production environments
- Rail transit command signaling centers and electrical power grid dispatch operations

## Technical specifications

- Refrigerant Type: Environmentally friendly R410A
- Rated Cooling Capacity: 22 kW (air-cooled cooling-only/electric heating/humidification)
- HMI Display Interface: 7-inch full-color HMI touchscreen (self-learning and self-diagnostics)
- Airflow Volume: High-air-volume, low-enthalpy-difference circulation design
- Grid Power Supply System: 380V 3-Phase / 220V 1-Phase Compatible
- Airflow Delivery & Fan Type: Optional upflow / downflow air supply
- Sensible Heat Ratio (SHF): \> 0.90 (high sensible heat ratio design)
- Control System & HMI: Large-screen graphical microcomputer controller with a fully Chinese-language interface
- Matching Outdoor Condenser: Standard configuration: DMC22M\*1 (-15℃~+45℃); optional low-temperature kit for -34℃
- Dimensions: 800mm (width) × 765mm (depth) × 1975mm (height) mm
- Operating Temperature Range: -15℃~+45℃ (supports -34℃ when equipped with a low-temperature condenser)
- Energy-saving functions: Economy operating mode as standard; up to 4 optional external sleep-mode energy-saving cards

## Frequently asked questions

### How do I choose the right Liebert DataMate3000-2 DME22 for my site?

Consider total sensible heat load, airflow configuration (upflow/downflow), ambient temperature limits, piping elevation and monitoring needs. Share your requirements with RICEWIND and we will compare suitable models from multiple brands for you.

### Is Liebert DataMate3000-2 DME22 compatible with my existing infrastructure?

Compatibility depends on power supply, refrigerant pipe dimensions and environmental monitoring protocols (RS-485/Modbus/SNMP). Our engineers can verify pipe sizing, wiring and BMS integration before you order.

### Does RICEWIND provide international shipping for Liebert DataMate3000-2 DME22?

Yes. Indoor and outdoor units are shipped globally with reinforced non-coniferous export wooden crates and nitrogen holding pressure. Freight options depend on destination port and urgency — contact us for a shipping quote.

### What warranty and technical support are available for Liebert DataMate3000-2 DME22?

Warranty follows the manufacturer policy for your region. RICEWIND provides installation drawings, commissioning documentation, OEM spare parts and engineer-level technical assistance throughout the project.

### Does RICEWIND supply Liebert DataMate3000-2 DME22?

Yes. RICEWIND supplies Liebert DataMate3000-2 DME22 from verified inventory, MOQ from 1 unit; in-stock units dispatch within 24-48 hours with worldwide shipping.

### Is there a cross-reference or equivalent for Liebert DataMate3000-2 DME22?

RICEWIND maintains a cross-reference database covering Vertiv (Liebert), Envicool, and Huawei thermal management systems. Contact us for direct equivalents or retrofit recommendations for Liebert DataMate3000-2 DME22.

### What are the core cooling parameters, Sensible Heat Ratio (SHF), and electrical ratings of the Vertiv Liebert DataMate3000-2 DME22?

The Liebert DataMate3000-2 DME22 delivers a nominal cooling capacity of 22.0 kW under standard data center conditions (24°C DB / 50% RH). Engineered specifically for high heat dissipation IT environments, it achieves a high Sensible Heat Ratio (SHF) exceeding 0.92 to prevent redundant dehumidification. The indoor unit operates on a high-airflow, low-enthalpy principle with an air volume of approximately 6,200 m³/h. Electrically, it requires a 380–415V AC 3-phase, 50/60Hz power supply. Standard configurations include a high-efficiency hermetic scroll compressor charged with R410A refrigerant, optional PTC electric heating (approx. 6.0 kW), and an electrode steam humidifier (approx. 3.0 kg/h), bringing the total Full Load Amperage (FLA) to typically 22–26A depending on installed heating/humidification stages.

### How does the DME22 address airflow configuration, group networking, and backward compatibility in legacy facility retrofits?

Housed in an 800mm (W) × 765mm (D) × 1975mm (H) compact footprint, the DME22 supports factory-configured upflow (front/top duct or plenum direct discharge) and downflow (raised floor under-floor pressurization) airflow schemes. For networking and telemetry, the integrated 7-inch color HMI runs Vertiv's Teamwork group control algorithm. Up to 32 indoor units can be linked via an RS-485 bus to execute scheduled duty rotation, automatic failover standby switching, cascade capacity staging, and anti-racing protection (avoiding simultaneous heating and cooling). It maintains native Modbus-RTU backward compatibility with legacy DataMate3000 deployments and accommodates optional Liebert IntelliSlot cards for SNMP/BACnet/IP integration into Vertiv Trellis or third-party DCIM frameworks.

### What are the terminal wiring safety rules, operating modes, and electrical specifications for the Vertiv Liebert ITA2 1kVA~3kVA?

According to the official Vertiv user manual: 1. Terminal Wiring Safety & Voltage Isolation: Before moving the UPS or performing re-wiring on terminals, all input power sources must be disconnected and the UPS must be completely shut down; otherwise, hazardous voltage may still exist at the output terminals. 2. Operating Modes: The unit supports Bypass Mode, Battery Mode, ECO Mode, and Fault Status. 3. Compliance & Standards: Certified to 2014/35/EU (LVD), 2014/30/EU (EMC), 2011/65/EU (RoHS), IEC/EN 62040-1 (general safety requirements), IEC/EN 62040-2 (Class C2 UPS; residential installation may require additional RF suppression measures), and IEC/EN 62040-3 performance/test methods. 4. Installation Guidelines: Installation and commissioning must strictly be carried out by factory-authorized certified engineers using designated manufacturer accessories.

Content updated: 2026-09-11T07:48:15.855Z