# Vertiv Liebert CR060 In-Row Variable Capacity Cooling Unit 600mm Wide (CRV4 Series 62.6kW)

RICEWIND · Vertiv

https://ricewind.com/en/products/liebert-crv4

Model: Liebert CR060

Vertiv Liebert CR060 is the flagship 600mm wide in-row precision cooling unit of the CRV4 series, delivering 62.6kW nominal cooling and 10,250 m³/h airflow for high-density server racks.

## What this product is

Vertiv Liebert CR060 is the flagship 600mm wide in-row precision cooling unit of the CRV4 series, delivering 62.6kW nominal cooling and 10,250 m³/h airflow for high-density server racks.

## What problem it solves

Vertiv Liebert CR060 600mm in-row precision air conditioner delivers 62.6kW capacity with full DC inverter modulation, engineered for AI and cloud data centers.

## Who and where it is for

Vertiv Liebert CR060 is the flagship 600mm wide in-row precision cooling unit of the CRV4 series, delivering 62.6kW nominal cooling and 10,250 m³/h airflow for high-density server racks.

## Core advantages

- 62.6kW ultra-large cooling capacity
- Full DC inverter compressor with stepless regulation
- Horizontal close-coupling supply air near the heat source
- Sensible heat ratio greater than 0.98

## Applications

- Hyperscale and enterprise cloud data center high-density server halls and aisle containment
- Telecommunications switching centers, optical transmission rooms, and carrier core facilities
- High-reliability industrial test laboratories and clean room production environments
- Rail transit command signaling centers and electrical power grid dispatch operations

## Technical specifications

- Full Load Current (FLA): 46.0 A
- Reheating Capacity: 6 kW
- Airflow Volume: 10,250 m³/h
- Airflow Mode & Volume: Horizontal horizontal air supply close to cabinet heat sources
- Refrigerant Type: Eco Refrigerant R410A
- Rated Cooling Capacity: 62.6 kW
- Physical Form Factor: 2000 × 600 × 1100 mm
- Sensible Heat Ratio (SHF): \> 0.98 (Ultra-High Sensible Heat Ratio)
- Grid Power Supply System: 380V 3-Phase / 220V 1-Phase Compatible
- Compressor Type: DC inverter scroll compressor + EC centrifugal fan
- Dimensions: 600mm (W) × 1100mm (D) × 2000mm (H) mm
- Subrack weight: 340 kg (net weight)

## Frequently asked questions

### How do I choose the right Liebert CR060 for my site?

Consider total sensible heat load, airflow configuration (upflow/downflow), ambient temperature limits, piping elevation and monitoring needs. Share your requirements with RICEWIND and we will compare suitable models from multiple brands for you.

### Is Liebert CR060 compatible with my existing infrastructure?

Compatibility depends on power supply, refrigerant pipe dimensions and environmental monitoring protocols (RS-485/Modbus/SNMP). Our engineers can verify pipe sizing, wiring and BMS integration before you order.

### Does RICEWIND provide international shipping for Liebert CR060?

Yes. Indoor and outdoor units are shipped globally with reinforced non-coniferous export wooden crates and nitrogen holding pressure. Freight options depend on destination port and urgency — contact us for a shipping quote.

### What warranty and technical support are available for Liebert CR060?

Warranty follows the manufacturer policy for your region. RICEWIND provides installation drawings, commissioning documentation, OEM spare parts and engineer-level technical assistance throughout the project.

### Does RICEWIND supply Liebert CR060?

Yes. RICEWIND supplies Liebert CR060 from verified inventory, MOQ from 1 unit; in-stock units dispatch within 24-48 hours with worldwide shipping.

### Is there a cross-reference or equivalent for Liebert CR060?

RICEWIND maintains a cross-reference database covering Vertiv (Liebert), Envicool, and Huawei thermal management systems. Contact us for direct equivalents or retrofit recommendations for Liebert CR060.

### What are the core thermodynamic cooling capacities, Sensible Heat Ratio (SHF), and electrical airflow metrics of the Vertiv Liebert CR060?

Engineered for high-density compute environments, the Vertiv Liebert CR060 (CRV4 series) delivers a nominal total cooling capacity of 62.6 kW under standard return air conditions (37.8°C DB / 20.8°C WB) with a Sensible Heat Ratio (SHF) exceeding 0.98, virtually eliminating latent cooling waste. The unit integrates a variable-speed DC inverter scroll compressor and high-efficiency backward-curved EC centrifugal fans, driving an airflow capacity of 10,250 m³/h with dynamic modulation tailored to real-time rack thermal loads. Operating on 380-415V/3Ph/50-60Hz utility power, the inverter system provides soft-start functionality with locked rotor amp (LRA) near zero, mitigating inrush current and optimizing data center PUE.

### How does the CR060 mechanically integrate into server rows, and what multi-unit teaming (Teamwork) protocols are supported?

The Liebert CR060 features a 600mm wide in-row footprint measuring 600mm(W) × 1100mm(D) × 2000mm(H) with a net weight of 340 kg, matching standard 42U/47U server racks and integrating seamlessly into hot/cold aisle containment systems. Managed by the Liebert iCOM controller, it natively provides RS485 and Dual Ethernet ports supporting Modbus RTU/TCP, SNMP v1/v2c/v3, and BACnet-IP. Up to 32 units can be networked via CAN-Bus or Ethernet for Teamwork operation, executing dynamic load sharing, scheduled duty-rotation, and N+X cascading redundancy. In the event of a network loss, individual units automatically revert to autonomous failsafe setpoint operation to prevent thermal runaway.

### What electrical protection, voltage tolerance, and wide-ambient adaptation mechanisms safeguard the Liebert CR060 against site anomalies?

Engineered for mission-critical reliability, the CR060 features an optional integrated Automatic Transfer Switch (ATS) accepting wide voltage fluctuations (nominal ±10%). The internal electrical cabinet includes Class C / 40kA surge suppression along with real-time phase-loss, reverse-phase, under-voltage, and over-current protection interlocks. For extreme climates, the unit interfaces with Vertiv variable-speed outdoor condensers (e.g., LSF series), utilizing low-ambient kits to sustain full-capacity operation from -40°C to +45°C ambient temperatures. Condensate management incorporates dual drainage pumps (lift head ≥ 4m), digital water leak detection ropes, and non-volatile memory for automatic cold-restart upon power restoration.

Content updated: 2026-09-11T07:48:15.815Z