# Huawei R4850G1 Ultra-High Efficiency Telecom Switch-Mode Rectifier Module (53.5V 50A 3000W)

RICEWIND · Huawei

https://ricewind.com/en/products/huawei-r4850g1-b28

Model: R4850G1

The Huawei R4850G1 is a carrier-grade digital high-frequency switch-mode telecom rectifier module engineered to supply a nominal -48V DC bus (adjustable from 42V to 58V DC, nominal 53.5V DC) delivering up to 50A current with a maximum rated capacity of 3000W.

## What this product is

The R4850G1 combines an internal input electromagnetic interference (EMI) stage, an active bridgeless/interleaved PFC stage, an isolated full-bridge LLC resonant DC-DC converter, and a multi-tasking DSP control board. The onboard controller executes high-frequency pulse-width modulation (PWM) while interfacing through an internal CAN bus to exchange telemetry (voltage, current, thermal profiles, and failure codes) with the host monitoring unit to ensure autonomous active load sharing across multiple parallel modules.

## What problem it solves

Resolves field vulnerabilities related to severe grid fluctuations, lightning surges, and low-voltage blackouts through its wide input window; eliminates severe heat losses and high operational expenditures caused by low-efficiency rectifiers; and circumvents single point of failure (SPOF) risks via hot-swappable N+1 redundancy architectures that allow live zero-downtime maintenance.

## Who and where it is for

Ideal for 5G wireless macro base stations, remote radio unit (RRU/BBU) outdoor enclosures, telecom central offices, edge data centers, railway signaling and traction power systems, and distributed industrial DC control cabinets.

## Core advantages

- Ultra-High Conversion Efficiency: Achieves over 96% peak efficiency, substantially slashing utility consumption and HVAC cooling demands.
- Resilient AC Grid Tolerance: Sustains full operation across 85V to 300V AC, providing linear power derating during low mains scenarios.
- Reliable Live Hot-Swappability: True blind-mate connector design allows live hot-swap insertion and removal without disrupting running loads.
- Fully Digitized Network Control: Embedded high-speed CAN interface provides automated addressing and full telemetry integration into central DCIM systems.

## Applications

- 5G and LTE outdoor telecom macro shelters and power cabinets
- Core telecom exchange stations and optical broadband access nodes
- Edge computing micro-datacenters and critical enterprise DC bus infrastructures
- Railway wayside signaling, safety interlocking, and SCADA automation systems

## Technical specifications

- Rated Output Voltage: -48VDC (-42V ~ -58V)
- Maximum Efficiency: ≥ 96.0%
- Operating Temperature Range: -40°C ~ +75°C
- Cooling System: Forced Air Cooling with Intelligent Speed Fan
- Protection Features: Over-voltage, Short-circuit, Over-temperature, Surge
- Hot-Swappable Support: Yes (Live Plug-and-Play Support)
- Total Harmonic Distortion (THD): ≤ 5% (Total Harmonic Distortion)
- Power Factor & THD: ≥ 0.99 at Rated Load
- Standard Compliance: CE, UL, RoHS, IEC 60950, EN 300 386

## Frequently asked questions

### How do I select R4850G1 for my power system?

Check output voltage, module power rating, efficiency class and compatibility with your existing rectifier shelf or controller. RICEWIND can verify fitment and propose the right quantity.

### Is R4850G1 compatible with my existing system?

Compatibility depends on the rectifier shelf, controller and communication protocol. Send your current system model to RICEWIND and our engineers will confirm which modules fit.

### Does RICEWIND provide international shipping for R4850G1?

Yes. Power modules and systems are packed in anti-static, export-standard crates and shipped worldwide. Delivery time and freight options depend on stock and destination — contact RICEWIND for quotes and lead times.

### What warranty and technical support apply to R4850G1?

Warranty follows the manufacturer's policy for the specific equipment. RICEWIND supports testing guidance, replacement requests, spare parts and technical coordination per order terms.

### Does RICEWIND supply R4850G1 from stock?

Yes. RICEWIND supplies R4850G1 from verified stock with MOQ from 1 piece; in-stock units dispatch within 24-48 hours with global express air and sea freight.

### Is there a cross-reference or equivalent for R4850G1?

RICEWIND maintains a comprehensive cross-reference chart covering Huawei, Vertiv (Emerson), Eltek, ZTE and Delta 48V telecom rectifiers. Contact us for the direct equivalent of R4850G1.

### What is the certified procedure for hot-swapping an R4850G1 module in a live system?

Ensure the module mechanical latch is disengaged. Align the module smoothly into the guide rails of the subrack and slide it firmly forward until the blind-mate backplane connectors mate completely. Engage the front mechanical latch to secure the module and trigger the interlock micro-switch. The internal DSP completes pre-charging and initial self-diagnostics within seconds, auto-negotiates its CAN node address with the monitoring unit, and smoothly ramps up current to balance the load with neighboring units without interrupting the -48V bus.

### How is the R4850G1 integrated into higher-level DCIM systems via SNMP or RS485?

The R4850G1 communicates natively with the system supervisory controller (such as Huawei SMU02B/SMU02C) over a dual-wire CAN bus. The supervisory controller acts as the central gateway, mapping the rectifier data points into standard SNMP MIBs for IP-based DCIM integration or into Modbus-RTU registers via an RS485 port. Network administrators can query real-time operating metrics, configure float/boost voltage limits, and handle alarm traps directly through central network management software.

### What are the exact triggers and operational behavior during Over-Voltage (OVP) and Over-Temperature (OTP) events?

If output DC voltage exceeds the hardware limit (typically 58.5V to 60V DC), the rectifier initiates a fast hardware-level gate-pulse cut-off within microseconds and enters an output latch-off state, requiring a manual re-seat or software reset command to clear. In OTP scenarios, when the internal heat sink thermistor registers temperatures above the threshold (typically 75°C to 80°C), the unit generates a high-temperature alarm and shuts down the power stage. It automatically re-engages once the internal temperature drops below the safe hysteresis threshold (approximately 65°C).

### What preventative maintenance protocol is recommended for R4850G1 field deployments?

Execute semi-annual or annual checks: Inspect and clear dust accumulation from the front air intake louvers and internal heat sinks using dry, low-pressure compressed air; inspect the brushless DC fan for mechanical friction, vibration, or reduced RPM reporting; inspect the rear blind-mate power and signal pins for signs of fretting corrosion or terminal heat discoloration; and verify via the monitoring unit that module current sharing deviation remains within ±5% across all parallel units.

Content updated: 2026-09-16T10:12:52.926Z