# Huawei R4815N1 High-Density Digital Telecom Rectifier Module (53.5V 15A 1000W)

RICEWIND · Huawei

https://ricewind.com/en/products/huawei-r4815n1-b30

Model: R4815N1

The Huawei R4815N1 is an ultra-compact, fully digitized single-phase telecom switch-mode rectifier module. It delivers a regulated nominal -48V DC output (adjustable from 42V to 58V DC, nominal 53.5V DC) with a maximum output current of 15A and a rated continuous power capacity of 1000W, engineered to convert AC utility or generator power into stabilized DC power for critical telecom infrastructure.

## What this product is

Architecturally, the R4815N1 employs a two-stage power conversion circuit: an active power factor correction (APFC) boost pre-regulator delivering \>0.99 power factor and low THD across variable line conditions, followed by an isolated high-frequency DC/DC resonant converter with synchronous rectification. Fully compliant with international safety and electromagnetic standards such as IEC/EN 60950, CISPR Class B, and ETSI 300 019, it utilizes blind-mate backplane connectors supporting live live-insertion without arcing.

## What problem it solves

The R4815N1 prevents common field failures caused by unstable power grids, severe brownouts, transient overvoltage surges, and localized thermal choking. Its ultra-wide operational window of 85V AC to 300V AC prevents dropped telecom connections in rural networks prone to severe line drops. Integrated thermal derating, continuous short-circuit protection, and autonomous overvoltage latching ensure hardware survival, eliminating unnecessary emergency maintenance truck rolls.

## Who and where it is for

Ideal for 4G/5G remote radio units (RRU) and baseband unit (BBU) cabinets, FTTx central office OLT installations, microwave transmission repeaters, industrial automation RTU enclosures, and distributed -48V DC telecom power frames.

## Core advantages

- Features a two-stage power architecture with APFC and high-frequency DC/DC resonance, delivering 1000W rated power and ≥94.0% peak efficiency.
- Supports an ultra-wide 85V-300V AC input voltage range, ensuring reliable grid adaptability and surge resistance in remote sites.
- Operates reliably in extreme temperatures from -40°C to +75°C with intelligent thermal derating for harsh outdoor environments.
- Supports zero-impact hot-swappable insertion and smart fan cooling with hardware interlock protection to minimize maintenance costs.

## Applications

- Distributed BBU/RRU 5G base station outdoor enclosures
- Fixed broadband access network OLT/ONU subracks
- Long-haul microwave relay and transmission repeater stations
- Substation SCADA and industrial IoT -48V DC backup power systems

## Technical specifications

- AC Input Voltage: 85V AC ~ 300V AC
- Maximum Output Current: 15A
- Rated Output Power: 1000W
- Rated Output Voltage: -48VDC (-42V ~ -58V)
- Maximum Efficiency: ≥ 93.0%
- Operating Temperature Range: -40°C ~ +75°C
- Cooling System: Forced Air Cooling with Intelligent Speed Fan
- Hot-Swappable Support: Yes (Live Hot-Pluggable / Plug-and-Play without Power Interruption)

## Frequently asked questions

### How do I select R4815N1 for my power system?

Check output voltage, module power rating, efficiency class and compatibility with your existing rectifier shelf or controller. RICEWIND can verify fitment and propose the right quantity.

### Is R4815N1 compatible with my existing system?

Compatibility depends on the rectifier shelf, controller and communication protocol. Send your current system model to RICEWIND and our engineers will confirm which modules fit.

### Does RICEWIND provide international shipping for R4815N1?

Yes. Power modules and systems are packed in anti-static, export-standard crates and shipped worldwide. Delivery time and freight options depend on stock and destination — contact RICEWIND for quotes and lead times.

### What warranty and technical support apply to R4815N1?

Warranty follows the manufacturer's policy for the specific equipment. RICEWIND supports testing guidance, replacement requests, spare parts and technical coordination per order terms.

### Does RICEWIND supply R4815N1 from stock?

Yes. RICEWIND supplies R4815N1 from verified stock with MOQ from 1 piece; in-stock units dispatch within 24-48 hours with global express air and sea freight.

### Is there a cross-reference or equivalent for R4815N1?

RICEWIND maintains a comprehensive cross-reference chart covering Huawei, Vertiv (Emerson), Eltek, ZTE and Delta 48V telecom rectifiers. Contact us for the direct equivalent of R4815N1.

### How does the R4815N1 behave when input grid voltage falls below 176V AC?

The R4815N1 features an internal linear derating mechanism. While it supplies full 1000W output between 176V AC and 300V AC, input voltages between 85V AC and 176V AC prompt the DSP to linearly scale back maximum current output to protect the input PFC inductors and switching FETs from overcurrent stress. At a 110V AC input, the module reliably delivers approximately 500W to 600W continuously without triggering an undervoltage shutdown.

### What is indicated when the module status LED turns solid or flashing yellow, and how should it be diagnosed?

A yellow LED indicates a warning condition. A flashing yellow LED signifies lost communication with the host monitoring unit (e.g., SMU02B/C) or a detected fan speed anomaly. A solid yellow LED indicates an active protective state that has not locked out the unit, such as an AC input over/undervoltage alarm, ambient over-temperature derating, or temporary thermal shutdown. Inspect the fan inlet for dust blockages, verify free fan spin, and check grid voltage stability.

### Can multiple R4815N1 units operate in parallel without an external controller?

Yes. When paired with a Huawei subrack, active current sharing is primarily managed via the CAN bus by the SMU controller to achieve an unbalance of less than ±5%. If the controller is removed or communication fails, each R4815N1 falls back to autonomous internal droop current-sharing circuitry. This ensures stable parallel operation, balanced thermal stress across modules, and continuous bus stability without crashing the DC load.

### What root causes trigger a solid red LED, and how can the rectifier be recovered?

A solid red LED indicates a critical lockout event: output overvoltage (OVP, typically triggered above 59.5V DC), continuous fan stall, or internal converter hardware failure. If an output transient triggered OVP latching, disconnect the module, wait at least three minutes for internal bulk capacitors to fully discharge, and re-insert it. If the red LED remains illuminated immediately upon re-insertion, internal component degradation has occurred and unit replacement is required.

Content updated: 2026-09-16T13:39:08.120Z