# Huawei M48500N1 Carrier-Grade High-Frequency Telecom Rectifier Module (-48V 50A 3000W)

RICEWIND · Huawei

https://ricewind.com/en/products/huawei-m48500n1-b31

Model: M48500N1

The Huawei M48500N1 is a carrier-grade high-frequency switched-mode telecom rectifier module designed to convert single-phase AC utility power (85V AC to 300V AC) into a highly stabilized -48V DC nominal output (adjustable from 42V to 58V DC, default 53.5V DC), delivering 3000W maximum rated power at up to 50A with a peak conversion efficiency of ≥95.0%.

## What this product is

The module integrates an Active Power Factor Correction (APFC) front stage with an isolated DC/DC resonant converter back stage, achieving a power factor of ≥0.99 and total harmonic distortion (THDi) under 5%. Internal microcontrollers continuously monitor operational parameters and relay diagnostics via an onboard CAN bus to central Power System Monitoring Units (SMU), enabling precision active parallel current sharing, smart battery temperature-compensated charging, and complete compliance with IEC/EN 60950 and ETSI standards.

## What problem it solves

It eliminates grid instability vulnerabilities such as severe undervoltage brownouts, high-energy transients, and utility phase shifts that frequently destroy standard industrial power supplies. Furthermore, it addresses DC bus voltage fluctuations during rapid load transitions, removes the risk of battery bank overcharging/thermal runaway, and eliminates service interruptions through non-disruptive hot-swap capability.

## Who and where it is for

Engineered for 4G/5G macro cell base station power cabinets, outdoor integrated telecom shelters, central enterprise switching centers, optical transmission nodes, distributed antenna systems (DAS), and mission-critical industrial -48V DC uninterruptible distribution setups.

## Core advantages

- Wide AC input range (85V-300V AC) handles unstable grids and severe voltage sags effortlessly.
- Peak conversion efficiency exceeding 95% with active PFC and ultra-low THDi below 5%.
- Supports live hot-swappable replacement and CAN bus communication for dynamic current sharing.
- Intelligent variable-speed forced air cooling complying with strict IEC/EN 60950 telecom standards.

## Applications

- DC power plant expansion within Huawei TP48200B, TP48300B, and similar telecom subracks
- Wireless cellular macro sites, edge RAN, and 5G small cell infrastructure power supply
- Railway communications, trackside signaling networks, and electrical utility SCADA systems
- Carrier aggregation centers, enterprise colocation facilities, and optical transport hubs

## Technical specifications

- AC Input Voltage: 85V AC ~ 300V AC
- Rated Output Voltage: -48VDC (-42V ~ -58V)
- Maximum Output Current: 50A
- Rated Output Power: 3000W
- Maximum Efficiency: ≥ 95.0%
- Operating Temperature Range: -40°C ~ +75°C
- Cooling System: Forced Air Cooling with Intelligent Speed Fan
- Hot-Swappable Support: Yes (Live Hot-Pluggable / Plug-and-Play without Power Interruption)

## Frequently asked questions

### How do I select M48500N1 for my power system?

Check output voltage, module power rating, efficiency class and compatibility with your existing rectifier shelf or controller. RICEWIND can verify fitment and propose the right quantity.

### Is M48500N1 compatible with my existing system?

Compatibility depends on the rectifier shelf, controller and communication protocol. Send your current system model to RICEWIND and our engineers will confirm which modules fit.

### Does RICEWIND provide international shipping for M48500N1?

Yes. Power modules and systems are packed in anti-static, export-standard crates and shipped worldwide. Delivery time and freight options depend on stock and destination — contact RICEWIND for quotes and lead times.

### What warranty and technical support apply to M48500N1?

Warranty follows the manufacturer's policy for the specific equipment. RICEWIND supports testing guidance, replacement requests, spare parts and technical coordination per order terms.

### Does RICEWIND supply M48500N1 from stock?

Yes. RICEWIND supplies M48500N1 from verified stock with MOQ from 1 piece; in-stock units dispatch within 24-48 hours with global express air and sea freight.

### Is there a cross-reference or equivalent for M48500N1?

RICEWIND maintains a comprehensive cross-reference chart covering Huawei, Vertiv (Emerson), Eltek, ZTE and Delta 48V telecom rectifiers. Contact us for the direct equivalent of M48500N1.

### What is the AC input derating behavior of the M48500N1 below 176V AC?

The module delivers its full 3000W (50A at 53.5V) output within an input window of 176V AC to 300V AC. When input voltage drops between 85V AC and 176V AC, the internal DSP initiates a controlled linear power derating strategy down to approximately 40% of rated capacity at 85V AC. This prevents primary-side overcurrent stress while maintaining continuous -48V DC bus feed under severe brownout conditions.

### How should an engineer interpret a solid yellow or flashing red LED indication on the front panel?

A solid yellow LED denotes a non-critical system warning or self-protection condition, such as input voltage outside nominal limits (AC brownout/overvoltage), thermal warning threshold, or remote sleep mode. A red LED (steady or flashing) signifies a protective trip or critical hardware fault, including output overvoltage protection (OVP lockout), internal overtemperature shutdown, fan failure/stall, or internal short-circuit. In this case, inspect airflow clearances, verify load integrity, and cycle AC power to clear latched faults.

### What causes active current sharing imbalance (\>5%) when adding a replacement M48500N1 into a live subrack?

Current sharing imbalance usually stems from communication degradation between the module and the System Monitoring Unit (SMU) via the CAN bus, mismatched firmware versions altering default reference parameters, or bent/dirty gold-plated signal pins on the backplane blind-mate connector. Confirm that the SMU recognizes the module, check that the DC float/equalize settings match the rest of the array, and inspect connector alignment.

### How does extreme ambient temperature (+55°C to +75°C) affect output performance and component reliability?

The M48500N1 maintains rated 3000W output from -40°C up to +55°C. At temperatures exceeding +55°C up to its maximum ceiling of +75°C, the module executes an active thermal derating profile based on internal heatsink thermistors to prevent semiconductor junction thermal breakdown. Continuous long-term operation above +55°C will accelerate primary capacitor electrolyte aging; periodic inspection and cleaning of air filters and fan grilles are essential in outdoor cabinets.

Content updated: 2026-09-17T01:31:05.444Z