# Huawei H805GPUF 16-Port GPON OLT Service Interface Board (2048 Subscribers 1:128 Split)

RICEWIND · Huawei

https://ricewind.com/en/products/huawei-h805gpuf-16-port-gpon-board

Model: Huawei H805GPUF 16-Port GPON Board

The Huawei H805GPUF is a high-density 16-port GPON service interface card for Huawei SmartAX MA5680T, MA5683T, and MA5608T OLT optical chassis, supporting up to 2,048 FTTH subscriber ONUs with a 1:128 optical split ratio and Class B+/C+/C++ transceivers.

## What this product is

High-density 16-port GPON central office OLT line card.

## What problem it solves

Maximizes subscriber capacity per slot up to 2,048 lines, lowering capital expenditure and central office power consumption.

## Who and where it is for

Huawei SmartAX MA5680T, MA5683T, and MA5608T optical line terminals.

## Core advantages

- 16 high-density GPON ports aggregating up to 2,048 active subscribers per card
- Supports high optical split ratios up to 1:128 to optimize fiber distribution topologies
- Broad optical transceiver interoperability across Class B+, Class C+, and Class C++
- Hardware-accelerated HQoS packet scheduling and automatic idle-port standby

## Applications

- Data center intelligent power distribution header cabinets and busway telemetry systems
- Master supervisory brain for telecom power plants and autonomous parallel rectifier fleets
- Substation battery bank string telemetry, cell impedance monitoring, and predictive alarms
- Integrated power and environment automation for remote unattended telecom hub stations

## Technical specifications

- Optical Split Ratio: Up to 1:128 Split Ratio
- Board type: Enhanced 16-port GPON OLT central-office service interface board
- Split ratio and terminal capacity: 1:128 split ratio
- Supported chassis: MA5680T / MA5683T / MA5608T
- Port Density & Specs: 16 full-line-rate GPON SFP ports
- Power consumption: Typical operating power consumption approx. 55W (with intelligent dynamic sleep energy saving)
- Subscriber Capacity: Maximum subscriber capacity per board: 2048 subscribers
- Operating Temperature Range: -40°C to +65°C

## Frequently asked questions

### How do I choose the right Huawei H805GPUF 16-Port GPON Board for my network?

Check port type, data rate, fiber type (single-mode/multi-mode), wavelength and link distance. RICEWIND can assist in verifying host compatibility and recommending verified options.

### Is Huawei H805GPUF 16-Port GPON Board compatible with my switches, routers, or base station equipment?

Most platforms support standard MSA modules, but some vendors enforce vendor coding or whitelist locks. Provide your switch or router model and RICEWIND can confirm coding and pre-test prior to dispatch.

### What warranty and support policy applies to Huawei H805GPUF 16-Port GPON Board?

Warranty follows the manufacturer policy for the specific part number. RICEWIND provides optical power test records and engineer-level replacement assistance per order terms.

### Does RICEWIND supply Huawei H805GPUF 16-Port GPON Board from stock?

Yes. RICEWIND supplies Huawei H805GPUF 16-Port GPON Board with MOQ from 1 unit; in-stock transceivers dispatch within 24-48 hours with global fast shipping.

### Is there a cross-reference or equivalent alternate for Huawei H805GPUF 16-Port GPON Board?

RICEWIND maintains a cross-reference matrix covering Huawei, ZTE, Cisco, and Finisar transceivers. Contact us for direct equivalents and cost-effective alternates for Huawei H805GPUF 16-Port GPON Board.

### How is Huawei H805GPUF 16-Port GPON Board packaged and shipped? Does RICEWIND ship internationally?

Optical transceivers are individually packed in anti-static clamshells and shockproof export cartons. RICEWIND ships worldwide; express air freight options depend on destination and urgency — contact us for quotes.

### What are the optical/electrical parameters, split ratio, and power consumption of the Huawei H805GPUF 16-port GPON board?

The Huawei H805GPUF line card features 16 standard GPON SFP ports adhering to ITU-T G.984.x standards, delivering downstream 2.488 Gbps and upstream 1.244 Gbps line-rate transmission. Supporting up to a 1:128 optical split ratio per port, a single board achieves a maximum capacity of 2048 ONT subscribers. Compatible with Class B+, C+, and C++ GPON SFP optical transceivers, it provides optical budgets of 28.5dB, 32dB, and 35dB respectively, facilitating transmission distances of 20km to 40km. The typical power consumption is engineered at approximately 55W (idle at ~25W), integrating dynamic energy-saving algorithms and automated idle-port shutdown to effectively reduce data center PUE.

### What hardware-grade protections does the H805GPUF incorporate for industrial temperature tolerance, surge immunity, and reliability?

Engineered for rugged telecom environments, the H805GPUF supports an operating temperature range of -40°C to +65°C and relative humidity of 5% to 95% (non-condensing). The PCB utilizes controlled impedance routing and protective conformal coating to guard against airborne dust, humidity, and salt spray. Power inputs and interface lines comply with ITU-T K.20/K.27 lightning protection and surge immunity standards (common mode 6kV, differential mode 4kV). Featuring isolated DC-DC step-down modules and an optimized thermal airflow design, it delivers balanced heat dissipation under 100% full-slot traffic, achieving an MTBF exceeding 100,000 hours.

### According to on-site engineering specifications, what are the mandatory operational requirements and protection standards for electrical connections and cabling?

According to original factory manual specifications, electrical connections and cabling must strictly adhere to the following: 1. Live-line installation or removal of cables is strictly prohibited. 2. When performing electrical connections, personnel must not wear conductive objects such as watches, bracelets, or rings; protective gloves are recommended. 3. Insulated tools must be used for electrical connections, and exposed sections of terminals must be adequately insulated. 4. Cable cross-sectional areas must match the actual load. Cable coloring must comply with local power grid engineering codes; black cables must be selected if non-standard colors are used. 5. When connecting battery packs in series, batteries must be of the same brand, model, specification, and manufacturing batch/time; short-circuiting batteries in any manner during operation is strictly prohibited.

Content updated: 2026-09-12T09:02:47.478Z
