# Huawei 4850N2 High-Efficiency Digital Switching Telecom Rectifier (53.5V 50A 3000W)

RICEWIND · Huawei

https://ricewind.com/en/products/huawei-4850n2-b30

Model: 4850N2

The Huawei 4850N2 is a carrier-grade high-efficiency digital telecom rectifier module rated for -48V DC nominal output (53.5V standard, adjustable from 42V to 58V DC) with a maximum current of 50A and a rated power of 3000W. Engineered with advanced high-frequency switching technology and digital signal processor (DSP) controls, it supplies robust, low-noise DC power for mission-critical telecommunications infrastructure.

## What this product is

Architecturally, the 4850N2 integrates a high-performance active boost PFC front-end with an isolated LLC resonant DC-DC converter, overseen by real-time DSP microcontrollers for cycle-by-cycle control and monitoring. The unit incorporates two-stage input EMI filtering, robust surge suppression, and synchronous rectification on the secondary side, meeting stringent ITU-T, IEC, and ETSI standards for electrical insulation and safety clearances.

## What problem it solves

It eliminates equipment damage and service downtime caused by unstable utility grids and severe phase fluctuations through an ultra-wide 85V to 300V AC input window. By delivering rapid digital transient response and precise current limit controls, it prevents DC bus voltage drops during abrupt load spikes and protects battery strings from accelerated sulfation through precise temperature-compensated charging regulation.

## Who and where it is for

Ideal for 4G/5G wireless base transceiver stations, optical fiber transmission nodes, enterprise core data closets, intelligent rail transport communications, and modular integration within Huawei ETP48 and TP48 series power distribution cabinets.

## Core advantages

- Features APFC and LLC resonant topologies, 85V-300V AC wide input, and ≥94.5% peak efficiency for superior energy savings.
- Supports live hot-swapping and dual-microprocessor digital control with zero bus voltage sag during sudden load steps.
- Integrated cycle-by-cycle current limiting and secondary EMI surge protection, compliant with ITU-T, IEC, and ETSI standards.
- Equipped with intelligent variable-speed cooling fans and closed-loop diagnostics to minimize OPEX in remote base stations.

## Applications

- Telecom outdoor macro base stations and micro sites housed in Huawei ETP48 power enclosures
- Central office optical switching nodes and enterprise telecom rooms requiring regulated -48V DC bus power
- Railway signaling, SCADA telemetry stations, and roadside transportation communications shelters
- Industrial automation substations and remote RTU control cabinets requiring continuous DC battery backup

## Technical specifications

- Maximum Output Current: 50A
- Rated Output Power: 3000W
- Rated Output Voltage: -48VDC (-42V ~ -58V)
- AC Input Voltage: 85V AC ~ 300V AC
- Maximum Efficiency: ≥ 94.5%
- Operating Temperature Range: -40°C ~ +75°C
- Cooling System: Forced Air Cooling with Intelligent Speed Fan
- Hot-Swappable Support: Yes (Live Hot-Pluggable / Plug-and-Play without Power Interruption)

## Frequently asked questions

### How do I select 4850N2 for my power system?

Check output voltage, module power rating, efficiency class and compatibility with your existing rectifier shelf or controller. RICEWIND can verify fitment and propose the right quantity.

### Is 4850N2 compatible with my existing system?

Compatibility depends on the rectifier shelf, controller and communication protocol. Send your current system model to RICEWIND and our engineers will confirm which modules fit.

### Does RICEWIND provide international shipping for 4850N2?

Yes. Power modules and systems are packed in anti-static, export-standard crates and shipped worldwide. Delivery time and freight options depend on stock and destination — contact RICEWIND for quotes and lead times.

### What warranty and technical support apply to 4850N2?

Warranty follows the manufacturer's policy for the specific equipment. RICEWIND supports testing guidance, replacement requests, spare parts and technical coordination per order terms.

### Does RICEWIND supply 4850N2 from stock?

Yes. RICEWIND supplies 4850N2 from verified stock with MOQ from 1 piece; in-stock units dispatch within 24-48 hours with global express air and sea freight.

### Is there a cross-reference or equivalent for 4850N2?

RICEWIND maintains a comprehensive cross-reference chart covering Huawei, Vertiv (Emerson), Eltek, ZTE and Delta 48V telecom rectifiers. Contact us for the direct equivalent of 4850N2.

### What is the output power derating behavior of the 4850N2 when the AC input drops below 176V?

The 4850N2 delivers its full 3000W output capacity within the 176V to 300V AC input range. If input voltage drops between 85V and 176V AC, the internal DSP initiates an automatic, linear power derating curve to prevent PFC stage overcurrent, delivering approximately 40% to 50% rated power at the lower 85V AC threshold without tripping.

### What does a steady yellow LED on the front panel indicate, and what are the troubleshooting steps?

A steady yellow LED indicates a protection mode. Common causes include AC input overvoltage or undervoltage (outside 85V–300V AC), internal over-temperature shutdown, or fan failure. To troubleshoot, verify that the incoming AC line voltage is within tolerance, ensure ambient air temperature does not exceed +75°C, and inspect the cooling air inlet for dust clogging.

### How does the 4850N2 achieve load balancing when multiple modules operate in parallel?

Load sharing is executed autonomously via digital CAN bus communication linking all rectifiers to the system controller (such as an SMU02C). The onboard DSP computes the dynamic load share and coordinates with peer modules, maintaining current unbalance to within ±5% of rated output between 50% and 100% system loading without requiring an analog bus.

### What precautions should be observed when hot-swapping a 4850N2 module under load?

First, disengage the locking mechanism by releasing the module extraction handle. Slowly pull the unit forward along the chassis guide rails until it clears the rear blind-mate receptacle. Before inserting a replacement, confirm the rear connector is free of debris, align with guide tracks, firmly push home until fully seated, and secure the mechanical latch to initialize soft-start.

Content updated: 2026-09-16T13:39:09.399Z