# Heda GERM4815TVP Compact Micro-Station High-Frequency Rectifier Module (-48V 15A 870W)

RICEWIND · Heda

https://ricewind.com/en/products/heda-germ4815tvp-b31

Model: GERM4815TVP

The Heda GERM4815TVP is a high-reliability, compact carrier-grade high-frequency switch-mode telecom rectifier module delivering a rated -48V DC output, up to 15A continuous current, and 870W output power across an adjustable voltage range of -43V to -58V DC.

## What this product is

Architecturally, the GERM4815TVP integrates an active Power Factor Correction (APFC) front-end achieving PF \> 0.99 with an isolated high-frequency soft-switching DC-DC secondary converter. Regulated by an embedded microcontroller, it features built-in digital telemetry, real-time input/output monitoring, temperature compensation, and compliance with stringent telecom-grade EMC, isolation, and lightning surge immunity standards.

## What problem it solves

The module resolves operational challenges associated with unstable grid quality (brownouts, surge spikes), tight installation spaces in outdoor street cabinets, and thermal degradation in remote micro-sites. It eliminates unplanned outages and bus voltage sags during field maintenance through spark-free hot swapping and automated thermal/load protection.

## Who and where it is for

Ideal for 4G/5G micro-base stations, distributed antenna system (DAS) hubs, remote radio unit (RRU) outdoor power cabinets, optical network terminal (ONT) distribution, and industrial IoT edge computing enclosures.

## Core advantages

- Advanced APFC and high-frequency soft-switching topology yield a power factor above 0.99 for minimal grid harmonic pollution.
- Engineered for compact micro-base stations with smart cooling transitions to thrive in harsh, high-temperature environments.
- Fully live hot-pluggable design prevents bus voltage sag and arcing during maintenance to ensure zero business interruption.
- Integrated microprocessor delivers intelligent digital monitoring and standard bus telemetry for optimized efficiency.

## Applications

- 4G/5G micro-cellular base stations and indoor distributed antenna power units
- Outdoor pole-mounted RRU/BBU integrated telecom power enclosures
- Substation, railway, and pipeline SCADA supervisory communication nodes
- Edge computing cabinets and industrial DC uninterruptible power systems

## Technical specifications

- Rated Output Power: 870W
- Maximum Output Current: 15A
- AC Input Voltage: 90V AC ~ 290V AC
- Rated Output Voltage: -48VDC (-42V ~ -58V)
- Maximum Efficiency: ≥ 92.5%
- Operating Temperature Range: -40°C ~ +75°C
- Cooling System: Natural Convection Cooling / Assist Fan
- Hot-Swappable Support: Yes (Live Hot-Pluggable / Plug-and-Play without Power Interruption)

## Frequently asked questions

### How do I select GERM4815TVP for my power system?

Check output voltage, module power rating, efficiency class and compatibility with your existing rectifier shelf or controller. RICEWIND can verify fitment and propose the right quantity.

### Is GERM4815TVP compatible with my existing system?

Compatibility depends on the rectifier shelf, controller and communication protocol. Send your current system model to RICEWIND and our engineers will confirm which modules fit.

### Does RICEWIND provide international shipping for GERM4815TVP?

Yes. Power modules and systems are packed in anti-static, export-standard crates and shipped worldwide. Delivery time and freight options depend on stock and destination — contact RICEWIND for quotes and lead times.

### What warranty and technical support apply to GERM4815TVP?

Warranty follows the manufacturer's policy for the specific equipment. RICEWIND supports testing guidance, replacement requests, spare parts and technical coordination per order terms.

### Does RICEWIND supply GERM4815TVP from stock?

Yes. RICEWIND supplies GERM4815TVP from verified stock with MOQ from 1 piece; in-stock units dispatch within 24-48 hours with global express air and sea freight.

### Is there a cross-reference or equivalent for GERM4815TVP?

RICEWIND maintains a comprehensive cross-reference chart covering Huawei, Vertiv (Emerson), Eltek, ZTE and Delta 48V telecom rectifiers. Contact us for the direct equivalent of GERM4815TVP.

### How does the GERM4815TVP behave when the AC input voltage drops below 176V AC?

The module incorporates an automatic low-voltage power derating profile. It provides full 870W (15A) capacity between 176V and 290V AC. Between 90V and 176V AC, the rectifier stays operational without tripping, linearly reducing maximum output power to protect internal components while sustaining connected telecom loads.

### What is the procedure to clear an Output Overvoltage Protection (OVP) latch-up state?

The OVP is hardware-latched (typically triggering at 59V ± 1V DC) to safeguard downstream carrier-grade electronics. To reset, disconnect the AC feed breaker or unplug the module from its subrack, wait roughly 30 to 60 seconds until internal bulk capacitors fully bleed down, and then restore input power.

### What causes severe current unbalance when operating multiple modules in parallel?

Check the backplane blind-mate connector for bent, recessed, or oxidized active current-share pins. Next, verify that each module's open-circuit reference voltage is calibrated identically within ±0.2V DC via the central controller. A damaged current-sharing differential op-amp circuit on a single unit will also induce load-sharing failure.

### How should an over-temperature alarm (amber LED) be resolved in high-ambient installations?

The module self-protects when its internal heat sink sensor surpasses safe operating thresholds. Inspect cabinet air-inlet filters for particulate clogging, verify that the module air path is unobstructed by cabling, confirm that external enclosure exhaust fans are operating properly, and verify that the ambient enclosure temperature has not exceeded +65°C.

Content updated: 2026-09-17T01:30:09.093Z