# Heda EPW30-48 Telecom Industrial Switch-Mode Power Rectifier Module (48V 30A 1600W)

RICEWIND · Heda

https://ricewind.com/en/products/heda-epw30-48-b31

Model: EPW30-48

The Heda EPW30-48 is an industrial carrier-grade switch-mode power rectifier module engineered for telecom central offices and cellular base station DC power plants, delivering a nominal -48V DC output (adjustable from 42V to 58V DC) with a maximum load current of 30A and a rated continuous power output of 1600W.

## What this product is

The EPW30-48 employs a high-frequency pulse-width modulated (PWM) dual-stage topology combining active power factor correction (APFC) with an isolated DC-DC resonant converter to deliver low-ripple telecom-quality -48V DC power. It integrates hardware-driven AC under/over-voltage shutdown, output over-voltage crowbar latching, output current limiting, thermal foldback, and localized telemetry interfaces compliant with global telecom and EMC standards.

## What problem it solves

Eliminates premature component burnout and brownout shutdowns in remote or unstable grid regions prone to severe voltage sags and transient surges; mitigates thermal runaway and current hogging in parallel redundant arrays; and eliminates downtime during maintenance via live hot-plug capability.

## Who and where it is for

Cellular base stations (BBU/RRU/macro sites), optical access network nodes (FTTx/OLT), microwave repeater terminals, utility substation automation SCADA racks, and industrial 48V DC uninterruptible power supply (UPS) enclosures.

## Core advantages

- Wide input voltage (90-290V AC) withstands unstable grids and surges, with APFC for high power factor.
- Delivers 48V 30A (1600W) with ≥92.0% efficiency, providing low-ripple telecom-grade DC bus power.
- Hardware-level protections against input/output over-voltage, current limiting, and over-temperature.
- Hot-swappable design with digital monitoring and zero circulating current for seamless base station expansion.

## Applications

- DC power subracks supporting macro base transceiver stations (BTS) and remote radio heads (RRH)
- Utility substation automation, power grid SCADA systems, and industrial RTU telecontrol racks
- Central office optical line terminals (OLT) and broadband access network distribution cabinets
- Railway signaling, trackside radio communications, and mission-critical TETRA repeater sites

## Technical specifications

- Rated Output Power: 1600W
- AC Input Voltage: 90V AC ~ 290V AC
- Rated Output Voltage: -48VDC (-42V ~ -58V)
- Maximum Output Current: 30A
- Maximum Efficiency: ≥ 92.0%
- Operating Temperature Range: -40°C ~ +75°C
- Cooling System: Forced Air Cooling with Intelligent Speed Fan
- Hot-Swappable Support: Yes (Live Hot-Pluggable / Plug-and-Play without Power Interruption)

## Frequently asked questions

### How do I select EPW30-48 for my power system?

Check output voltage, module power rating, efficiency class and compatibility with your existing rectifier shelf or controller. RICEWIND can verify fitment and propose the right quantity.

### Is EPW30-48 compatible with my existing system?

Compatibility depends on the rectifier shelf, controller and communication protocol. Send your current system model to RICEWIND and our engineers will confirm which modules fit.

### Does RICEWIND provide international shipping for EPW30-48?

Yes. Power modules and systems are packed in anti-static, export-standard crates and shipped worldwide. Delivery time and freight options depend on stock and destination — contact RICEWIND for quotes and lead times.

### What warranty and technical support apply to EPW30-48?

Warranty follows the manufacturer's policy for the specific equipment. RICEWIND supports testing guidance, replacement requests, spare parts and technical coordination per order terms.

### Does RICEWIND supply EPW30-48 from stock?

Yes. RICEWIND supplies EPW30-48 from verified stock with MOQ from 1 piece; in-stock units dispatch within 24-48 hours with global express air and sea freight.

### Is there a cross-reference or equivalent for EPW30-48?

RICEWIND maintains a comprehensive cross-reference chart covering Huawei, Vertiv (Emerson), Eltek, ZTE and Delta 48V telecom rectifiers. Contact us for the direct equivalent of EPW30-48.

### Can the EPW30-48 deliver its full 1600W rated output when AC input drops below 176V AC?

No. The EPW30-48 incorporates an internal linear power derating characteristic to protect its primary-side switching components from thermal overload. Full 1600W output (48V/30A) is sustained across 176V to 290V AC. When grid voltage falls between 90V and 176V AC, maximum available output power scales down proportionally, returning to full output automatically once nominal voltage is restored.

### What steps should be taken if an EPW30-48 latches into an Output Over-Voltage Protection (OVP) shutdown with a red LED?

The OVP circuit is hardware-latched to protect downstream telecom loads. First, verify whether the external DC bus voltage is being back-fed by an adjacent module or battery misconfiguration. If the external bus is normal, cycle the AC input breaker (or pull the module from the slot) for at least 60 to 90 seconds to discharge internal control capacitors, then re-insert it. If the red fault LED trips immediately upon re-energizing, the internal feedback loop or optocoupler has failed, requiring module repair.

### Why would multiple EPW30-48 modules in a common power shelf exhibit poor current sharing?

Standard current sharing imbalance is strictly within ±5%. Severe imbalance is typically caused by: a bent, oxidized, or recessed share-bus pin on the rear blind-mate connector; mismatched output voltage calibrations configured by the system controller; or localized thermal throttling if one module's air intake is restricted by dust accumulation.

### What causes the internal cooling fan to run continuously at maximum speed with an amber LED warning?

The EPW30-48 uses closed-loop tachometer feedback to govern fan speed. If the internal MCU loses the tachometer pulse signal or detects a failure in the NTC thermal sensor, it enters a failsafe state, driving the fan to 100% duty cycle to avoid thermal damage. Check the intake vent for obstructions, clean dust build-up, and replace the fan assembly if tachometer continuity is lost.

Content updated: 2026-09-16T16:04:31.202Z