# Eltek Flatpack2 48/3000 HE Flagship High Efficiency Rectifier (48V 60A 3000W)

RICEWIND · Eltek

https://ricewind.com/en/products/flatpack2-48-3000-he

Model: Flatpack2 48/3000 HE

SKU: ELTEK-REC-FP2-3000-HE

Eltek Flatpack2 48/3000 HE is a flagship 3000W (-48V/60A) rectifier module offering 96.5% high efficiency and intelligent CAN-bus control via Smartpack2.

## What this product is

Telecom-grade power infrastructure module designed for ELTEK power architecture.

## What problem it solves

Eliminates grid power anomalies and brownout hazards across mission-critical communication centers.

## Who and where it is for

Cellular wireless sites, optical broadband hubs, edge computing racks, and industrial private networks.

## Core advantages

- Ultra-high efficiency exceeding 96.5%, significantly reducing energy loss and carbon footprint in telecom sites.
- Wide AC input range from 85VAC to 300VAC, ensuring stable operation under unstable grid conditions.
- Extreme environment resilience with -40°C to +75°C operating temperature and smart thermal derating.
- High-density 1U compact form factor (41.5×109×327mm), optimizing space in standard telecom racks.

## Applications

- Telecom 4G/5G macro cellular base stations and distributed remote power sites
- Enterprise-grade cloud data center mission-critical -48V DC power distribution lineups
- Utility power grid dispatch centers and high-voltage substation DC switchgear rooms
- Railway transit signaling, automated train control, and communications equipment rooms

## Technical specifications

- AC input voltage range: 85VAC ~ 300VAC (Nominal 185~275VAC)
- Cooling method: Built-in fan-forced air cooling and automatic derating protection against overtemperature
- Conversion efficiency: ≥ 96.5%
- Overall System Efficiency: Up to 96.2% (Gold Standard)
- DC output voltage range: -48VDC (-42V ~ -58V)
- Acoustic Noise: ≤ 55 dBA (at 25°C ambient load)
- Ingress Protection Rating: IP20 (Indoor Dust & Finger Proof)
- Operating Temperature Range: -40°C ~ +75°C
- Dielectric Withstand Voltage: 3000VAC Input to Ground (\< 5mA)
- Dimensions: 41.5 (1U) × 109 × 327 mm

## Frequently asked questions

### How do I select Flatpack2 48/3000 HE for my power system?

Check output voltage, module power rating, efficiency class and compatibility with your existing rectifier shelf or controller. RICEWIND can verify fitment and propose the right quantity.

### Is Flatpack2 48/3000 HE compatible with my existing system?

Compatibility depends on the rectifier shelf, controller and communication protocol. Send your current system model to RICEWIND and our engineers will confirm which modules fit.

### Does RICEWIND provide international shipping for Flatpack2 48/3000 HE?

Yes. Power modules and systems are packed in anti-static, export-standard crates and shipped worldwide. Delivery time and freight options depend on stock and destination — contact RICEWIND for quotes and lead times.

### What warranty and technical support apply to Flatpack2 48/3000 HE?

Warranty follows the manufacturer's policy for the specific equipment. RICEWIND supports testing guidance, replacement requests, spare parts and technical coordination per order terms.

### Does RICEWIND supply Flatpack2 48/3000 HE from stock?

Yes. RICEWIND supplies Flatpack2 48/3000 HE from verified stock with MOQ from 1 piece; in-stock units dispatch within 24-48 hours with global express air and sea freight.

### Is there a cross-reference or equivalent for Flatpack2 48/3000 HE?

RICEWIND maintains a comprehensive cross-reference chart covering Huawei, Vertiv (Emerson), Eltek, ZTE and Delta 48V telecom rectifiers. Contact us for the direct equivalent of Flatpack2 48/3000 HE.

### What are the core electrical specifications and power efficiency metrics of the Eltek Flatpack2 48/3000 HE (ELTEK-REC-FP2-3000-HE)?

The Eltek Flatpack2 48/3000 HE delivers an engineering-grade nominal output of 3000W at -48VDC (adjustable from 43.5V to 57.6VDC) with a maximum continuous output current of 62.5A (nominal 60A). Featuring advanced high-frequency soft-switching resonance topology, it achieves a peak efficiency of 96.5% with power factor \>0.99 and THD \<5%. The AC input voltage spans from 85VAC to 300VAC, providing full 3000W output within the nominal 185VAC–275VAC envelope and smooth linear derating below 185VAC down to 85VAC to prevent system drops.

### Which Eltek power shelves and controllers support this module, and does it allow hot-swap expansion with legacy Flatpack2 units?

Designed in a standard 1U form factor (41.5×109×327 mm), the Flatpack2 48/3000 HE natively fits Eltek Flatpack2 1U/2U/3U 19-inch racks and Compact DC systems. It communicates over high-speed digital CAN bus with Smartpack, Smartpack S, and Smartpack2 monitoring controllers. The module incorporates true hot-swap capabilities and autonomous digital active current sharing (imbalance \<±5%), allowing seamless parallel expansion and mixed deployment alongside legacy Flatpack2 48/2000 or standard 48/3000 modules on the same DC bus.

### What protection architectures and environmental durability specifications ensure the reliability of Flatpack2 48/3000 HE?

The module operates within a harsh temperature envelope of -40°C to +75°C, delivering full 3000W rated output up to +55°C with automatic thermal derating up to +75°C driven by smart internal forced-air fans. Integrated input metal oxide varistors (MOV) provide surge immunity up to 4kV/2kA and sustain input surges up to 300VAC. Critical protection layers include output overvoltage latch-off (OVP), input undervoltage shutdown, continuous short-circuit protection, and galvanic isolation, achieving a verified MTBF exceeding 350,000 hours per Telcordia SR-332.

Content updated: 2026-09-11T00:57:37.024Z