# Eltek Flatpack2 48/2000 HE High Efficiency Telecom Rectifier (48V 40A 2000W)

RICEWIND · Eltek

https://ricewind.com/en/products/flatpack2-48-2000-he

Model: Flatpack2 48/2000 HE

SKU: ELTEK-REC-FP2-2000-HE

Eltek Flatpack2 48/2000 HE delivers benchmark 96.5% high-efficiency conversion in a 1U slim form factor (-48V/40A), significantly cutting OPEX for operators.

## What this product is

Telecom-grade power infrastructure module designed for ELTEK power architecture.

## What problem it solves

Eliminates grid power anomalies and brownout hazards across mission-critical communication centers.

## Who and where it is for

Cellular wireless sites, optical broadband hubs, edge computing racks, and industrial private networks.

## Core advantages

- Ultra-high efficiency exceeding 96.5%, significantly lowering OPEX and site PUE
- Wide input voltage range (85-300VAC) ensures stable operation in unstable grids
- Compact 1U form factor with hot-swappable architecture for zero-downtime scalability
- Industrial wide operating temperature (-40°C to +75°C) for extreme environments

## Applications

- Telecom 4G/5G macro cellular base stations and distributed remote power sites
- Enterprise-grade cloud data center mission-critical -48V DC power distribution lineups
- Utility power grid dispatch centers and high-voltage substation DC switchgear rooms
- Railway transit signaling, automated train control, and communications equipment rooms

## Technical specifications

- AC input voltage range: 85VAC ~ 300VAC (Nominal 185~275VAC)
- Cooling method: Front-to-rear airflow cooling with a stepless variable-speed DC fan
- Conversion efficiency: ≥ 96.5%
- Overall System Efficiency: Up to 96.2% (Gold Standard)
- Ingress Protection Rating: IP20 (Indoor Dust & Finger Proof)
- Acoustic Noise: ≤ 55 dBA (at 25°C ambient load)
- DC output voltage range: -48VDC (-42V ~ -58V)
- Dimensions: 41.5 (1U) × 109 × 327 mm
- Dielectric Withstand Voltage: 3000VAC Input to Ground (\< 5mA)
- Operating Temperature Range: -40°C ~ +75°C

## Frequently asked questions

### How do I select Flatpack2 48/2000 HE for my power system?

Check output voltage, module power rating, efficiency class and compatibility with your existing rectifier shelf or controller. RICEWIND can verify fitment and propose the right quantity.

### Is Flatpack2 48/2000 HE compatible with my existing system?

Compatibility depends on the rectifier shelf, controller and communication protocol. Send your current system model to RICEWIND and our engineers will confirm which modules fit.

### Does RICEWIND provide international shipping for Flatpack2 48/2000 HE?

Yes. Power modules and systems are packed in anti-static, export-standard crates and shipped worldwide. Delivery time and freight options depend on stock and destination — contact RICEWIND for quotes and lead times.

### What warranty and technical support apply to Flatpack2 48/2000 HE?

Warranty follows the manufacturer's policy for the specific equipment. RICEWIND supports testing guidance, replacement requests, spare parts and technical coordination per order terms.

### Does RICEWIND supply Flatpack2 48/2000 HE from stock?

Yes. RICEWIND supplies Flatpack2 48/2000 HE from verified stock with MOQ from 1 piece; in-stock units dispatch within 24-48 hours with global express air and sea freight.

### Is there a cross-reference or equivalent for Flatpack2 48/2000 HE?

RICEWIND maintains a comprehensive cross-reference chart covering Huawei, Vertiv (Emerson), Eltek, ZTE and Delta 48V telecom rectifiers. Contact us for the direct equivalent of Flatpack2 48/2000 HE.

### What are the environmental tolerance specs and thermal/surge protection mechanisms of this rectifier in harsh telecom deployments?

The module operates within an extreme temperature range of -40°C to +75°C (with intelligent linear derating above +45°C to preserve operational integrity). Forced-air front-to-back cooling is managed by an integrated, microprocessor-governed variable-speed DC fan that dynamically matches airflow to internal heat dissipation. Protection measures include Over-Temperature Protection (OTP), Over-Voltage Protection (OVP), short-circuit current limiting, and DC reverse polarity protection. The AC input integrates MOV protection compliant with IEC 61000-4-5 surge standards (2kV DM / 4kV CM), achieving an MTBF exceeding 350,000 hours per Telcordia SR-332.

### What are the core electrical conversion specifications and rated output metrics of the Eltek Flatpack2 48/2000 HE (ELTEK-REC-FP2-2000-HE)?

The Eltek Flatpack2 48/2000 HE rectifier provides a nominal -48V DC output with a rated capacity of 2000W and a maximum continuous current of 41.7A (adjustable from 43.5V to 57.6V DC). Operating on advanced soft-switching topology, it delivers a peak conversion efficiency of 96.5% (High Efficiency standard), a Power Factor (PFC) ≥ 0.99, and THD \< 5%. It features a wide AC input range from 85VAC to 300VAC (full 2000W output between 185VAC and 275VAC, with linear derating below 185VAC), substantially reducing facility thermal dissipation and optimizing telecom site PUE.

Content updated: 2026-09-11T00:57:36.989Z