# Eltek Flatpack S 48/1800 HE High-Density Shallow Rectifier Module (Part No. 241122.125)

RICEWIND · Eltek

https://ricewind.com/en/products/flatpack-s-1800-he-241122

Model: Flatpack S 48/1800 HE

The Eltek Flatpack S 48/1800 HE (Part No. 241122.125) is an ultra-compact shallow-depth high-efficiency telecom rectifier module delivering 1800W (-48V/37.5A) with over 95.5% peak conversion efficiency for space-constrained telecom applications.

## What this product is

Shallow-depth high-density switch-mode telecom DC rectifier module.

## What problem it solves

Delivers full 1800W power density inside shallow outdoor enclosures under 300mm depth where standard rectifiers cannot fit.

## Who and where it is for

5G small cell shallow cabinets, outdoor pole-mount enclosures, and embedded Flatpack S power shelves.

## Core advantages

- 1800W high power output with 37.5A continuous DC delivery
- Ultra-short 210mm depth fits shallow cabinet profiles
- Peak energy efficiency exceeding 95.5% minimizes heat dissipation
- Ergonomic one-handed hot-plug locking mechanism

## Applications

- Telecom 4G/5G macro cellular base stations and distributed remote power sites
- Enterprise-grade cloud data center mission-critical -48V DC power distribution lineups
- Utility power grid dispatch centers and high-voltage substation DC switchgear rooms
- Railway transit signaling, automated train control, and communications equipment rooms

## Technical specifications

- Rated Output Power: 1800W (37.5A @ 48V)
- Conversion efficiency: ≥ 95.5%
- AC Input Voltage: 100 ~ 250 VAC
- Overall System Efficiency: Up to 96.2% (Gold Standard)
- Acoustic Noise: ≤ 55 dBA (at 25°C ambient load)
- Ingress Protection Rating: IP20 (Indoor Dust & Finger Proof)
- Operating Temperature Range: -40°C ~ +85°C
- Dielectric Withstand Voltage: 3000VAC Input to Ground (\< 5mA)
- DC output voltage range: -48VDC (-42V ~ -58V) V DC
- Dimensions: 41.5 (1U) × 109 × 210 mm

## Frequently asked questions

### How do I select Flatpack S 48/1800 HE for my power system?

Check output voltage, module power rating, efficiency class and compatibility with your existing rectifier shelf or controller. RICEWIND can verify fitment and propose the right quantity.

### Is Flatpack S 48/1800 HE compatible with my existing system?

Compatibility depends on the rectifier shelf, controller and communication protocol. Send your current system model to RICEWIND and our engineers will confirm which modules fit.

### Does RICEWIND provide international shipping for Flatpack S 48/1800 HE?

Yes. Power modules and systems are packed in anti-static, export-standard crates and shipped worldwide. Delivery time and freight options depend on stock and destination — contact RICEWIND for quotes and lead times.

### What warranty and technical support apply to Flatpack S 48/1800 HE?

Warranty follows the manufacturer's policy for the specific equipment. RICEWIND supports testing guidance, replacement requests, spare parts and technical coordination per order terms.

### Does RICEWIND supply Flatpack S 48/1800 HE from stock?

Yes. RICEWIND supplies Flatpack S 48/1800 HE from verified stock with MOQ from 1 piece; in-stock units dispatch within 24-48 hours with global express air and sea freight.

### Is there a cross-reference or equivalent for Flatpack S 48/1800 HE?

RICEWIND maintains a comprehensive cross-reference chart covering Huawei, Vertiv (Emerson), Eltek, ZTE and Delta 48V telecom rectifiers. Contact us for the direct equivalent of Flatpack S 48/1800 HE.

### What are the core electrical specifications and input voltage derating characteristics of the Eltek Flatpack S 48/1800 HE (241122.125)?

The Eltek Flatpack S 48/1800 HE rectifier delivers a nominal -48V DC output (adjustable from 43.5 to 57.6 VDC) with a maximum power of 1800W and rated current of 37.5A under 185–275 VAC input. It achieves a peak efficiency of \>95.5% (HE standard), with PF ≥ 0.99 and THD ≤ 5%. When AC input operates between 100 and 185 VAC, an internal linear derating profile protects the unit while sustaining continuous output (delivering approximately 900W / 18.75A at 100 VAC), ensuring uninterrupted DC operation for telecom loads under degraded grid conditions.

### What are the thermal management and electrical protection standards of the Flatpack S 48/1800 HE under harsh environmental and grid conditions?

The module operates across -40°C to +85°C ambient temperature. It delivers 100% full-load output from -40°C to +55°C, above which internal intelligent thermal derating manages safe operation up to +85°C shutdown. Cooling is driven by a variable-speed brushless DC fan with front-to-back airflow. Electrical protection includes surge immunity per IEC 61000-4-5 (2kV DM / 4kV CM), AC overvoltage sustain up to 300 VAC with automatic shutdown, DC short-circuit recovery, output OVP latching, and MTBF exceeding 350,000 hours (Telcordia SR-332).

Content updated: 2026-09-12T07:07:36.356Z