# Eltek Flatpack S 48/1000 HE Ultra-Compact High Efficiency Rectifier Module (-48V 20A 1000W)

RICEWIND · Eltek

https://ricewind.com/en/products/flatpack-s-1000-he

Model: Flatpack S 48/1000 HE

The Eltek Flatpack S 48/1000 HE is an ultra-compact shallow-depth high-efficiency telecom rectifier module delivering 1000W (-48V/20A) with over 95.5% peak conversion efficiency for space-restricted telecom enclosures.

## What this product is

Ultra-compact shallow-depth high-efficiency telecom DC rectifier module.

## What problem it solves

Fits shallow outdoor enclosures (under 300mm depth) where standard full-length rectifiers cannot physically install.

## Who and where it is for

5G small cell cabinets, optical distribution frames, shallow embedded subracks, and IoT aggregation nodes.

## Core advantages

- Ultra-short 210mm depth specifically engineered for shallow cabinet enclosures
- Peak power conversion efficiency exceeding 95.5% reduces internal thermal dissipation
- True one-handed tool-free hot-plug installation
- Full digital DSP processing with CAN-bus supervisory integration

## Applications

- Telecom 4G/5G macro cellular base stations and distributed remote power sites
- Enterprise-grade cloud data center mission-critical -48V DC power distribution lineups
- Utility power grid dispatch centers and high-voltage substation DC switchgear rooms
- Railway transit signaling, automated train control, and communications equipment rooms

## Technical specifications

- Rated Output Power: 1000 W
- Nominal DC voltage: -48VDC (-42V ~ -58V) VDC
- Nameplate output current: 20.8 A
- Conversion efficiency: ≥ 95.5%
- AC Input Voltage: 85 ~ 305 VAC
- Operating Temperature Range: -40°C ~ +85°C
- Output voltage range: -48VDC (-42V ~ -58V) VDC
- Power factor: \> 0.99
- Dimensions: 41.5 × 72 × 210 mm (ultra-short chassis depth, suitable for shallow cabinets)

## Frequently asked questions

### How do I select Flatpack S 48/1000 HE for my power system?

Check output voltage, module power rating, efficiency class and compatibility with your existing rectifier shelf or controller. RICEWIND can verify fitment and propose the right quantity.

### Is Flatpack S 48/1000 HE compatible with my existing system?

Compatibility depends on the rectifier shelf, controller and communication protocol. Send your current system model to RICEWIND and our engineers will confirm which modules fit.

### Does RICEWIND provide international shipping for Flatpack S 48/1000 HE?

Yes. Power modules and systems are packed in anti-static, export-standard crates and shipped worldwide. Delivery time and freight options depend on stock and destination — contact RICEWIND for quotes and lead times.

### What warranty and technical support apply to Flatpack S 48/1000 HE?

Warranty follows the manufacturer's policy for the specific equipment. RICEWIND supports testing guidance, replacement requests, spare parts and technical coordination per order terms.

### Does RICEWIND supply Flatpack S 48/1000 HE from stock?

Yes. RICEWIND supplies Flatpack S 48/1000 HE from verified stock with MOQ from 1 piece; in-stock units dispatch within 24-48 hours with global express air and sea freight.

### Is there a cross-reference or equivalent for Flatpack S 48/1000 HE?

RICEWIND maintains a comprehensive cross-reference chart covering Huawei, Vertiv (Emerson), Eltek, ZTE and Delta 48V telecom rectifiers. Contact us for the direct equivalent of Flatpack S 48/1000 HE.

### What are the core electrical parameters and efficiency ratings of the Eltek Flatpack S 48/1000 HE, and how does it derate under low AC input voltages?

The Eltek Flatpack S 48/1000 HE (SKU: ELTEK-REC-FPS-1000-HE) delivers a nominal -48VDC output (adjustable from -43.5 to -57.6 VDC) with a rated current of 20.8A and 1000W continuous output. It achieves peak conversion efficiency of 95.5% (HE standard), a power factor \> 0.99, and THD \< 5%. The AC input spans 85 to 305 VAC (45–66 Hz). Operating characteristics include full 1000W output delivery within 176–305 VAC, and progressive linear derating when input drops between 85 and 176 VAC (derating to approximately 450W–500W at 85 VAC) to prevent AC-side overcurrent tripping while maintaining non-stop DC bus availability.

### Which power shelf platforms support the Flatpack S 48/1000 HE, and how do active load sharing and hot-swapping operate in parallel configurations?

With an ultra-short depth of only 210mm, the Flatpack S 48/1000 HE fits Eltek 1U/2U Flatpack S subracks (such as 1U 2-position, 1U 3-position shelves, and Power Core systems), making it ideal for shallow 300mm outdoor telecommunication enclosures. Communication is driven via CAN bus directly to Smartpack S or Smartpack Touch supervisory units. The unit incorporates active digital current sharing with parallel unbalance \< 5% across multiple rectifiers. It supports true live hot-swapping via high-reliability blind-mate rear connectors with first-mate last-break grounding, allowing smooth integration alongside Flatpack S 48/1800 HE units under automated controller load management.

### What reliability engineering and environmental protections does the Flatpack S 48/1000 HE feature for harsh thermal and unstable grid conditions?

The module operates from -40°C to +75°C (-40°F to +167°F), delivering 100% nominal power up to +55°C before initiating graceful thermal derating up to its +75°C shutdown threshold. Internal forced convection cooling is handled by a front-to-back variable-speed fan linked to ambient and internal temperature sensors. Electrical resilience includes built-in MOVs and filters compliant with IEC 61000-4-5 surge immunity (2kV differential / 4kV common mode) and Telcordia Class B EMI. Protective circuitry integrates AC overvoltage cutoff (withstanding sustained 305VAC and transient 415VAC swells), hardware DC Overvoltage Protection (OVP) latching, short-circuit current limit, and Over Temperature Protection (OTP), achieving an MTBF exceeding 350,000 hours (Telcordia SR-332).

Content updated: 2026-09-12T05:41:19.418Z