# Huawei ETP48200-C5B7002 Subrack Telecom DC Power System (-48V 200A 5U)

RICEWIND · Huawei

https://ricewind.com/en/products/etp48200-c5b7002

Model: ETP48200-C5B7002

The ETP48200-C5B7002 is a 5U carrier-grade embedded AC/DC rectifier power system delivering up to 200A nominal output at -48VDC, controlled by the SMU02C monitoring unit and supporting hot-swappable high-efficiency rectifiers.

## What this product is

The Huawei ETP48200-C5B7002 is engineered for telecom radio access networks, transmission nodes, enterprise communication networks, and small-to-medium central offices. Integrated within a standard 19-inch 5U subrack, it houses AC input terminals, rectifier slots, DC distribution breakers, the SMU02C monitoring controller, and dual low-voltage disconnection contactors (LLVD and BLVD) to secure uninterrupted -48VDC power supply.

## What problem it solves

Resolves erratic grid instabilities in remote stations through ultra-wide input voltage tolerance, minimizes rack footprint via high power density, and prevents irreversible battery destruction during prolonged outages using precision dual-tier disconnection.

## Who and where it is for

4G/5G macro cell stations, transmission repeater nodes, FTTx central offices, industrial communication racks, and enterprise core IT/networking rooms.

## Core advantages

- Ultra-wide 85VAC to 300VAC operational input range, sustaining up to 415VAC phase voltage without damage
- High-efficiency rectifier architecture achieving ≥96.0% peak conversion, minimizing site thermal emission
- Fully hot-swappable rectifiers and central monitoring controller for zero-downtime maintenance and scaling
- Intelligent multi-stage battery management: thermal compensation, auto boost/float switching, and programmable LLVD/BLVD
- Extensive south/northbound interfaces (Fast Ethernet, RS485, CAN) natively supporting SNMP v2/v3 and Huawei NetEco

## Applications

- Telecom 4G/5G macro cellular base stations and distributed remote power sites
- Enterprise-grade cloud data center mission-critical -48V DC power distribution lineups
- Utility power grid dispatch centers and high-voltage substation DC switchgear rooms
- Railway transit signaling, automated train control, and communications equipment rooms

## Technical specifications

- Smart Monitoring Controller: SMU02B / SMU02C Smart Monitoring Unit
- AC Input Voltage: 85VAC ~ 300VAC (1-Phase 220V / 3-Phase 380V Compatible) VAC
- Cooling System Architecture: Built-in speed-controlled fan cooling
- Nominal Output Voltage: -48VDC (-42V ~ -58V) VDC
- Managed Rectifier Capacity: 4 × 50A
- Rated DC Output Current: 200A (System Capacity 11.6kW)
- Peak Energy Efficiency: ≥96.0%
- Form Factor Dimensions (HxWxD): 222 (5U) × 442 × 360 mm
- Operating Temperature Range: -40°C ~ +65°C

## Frequently asked questions

### How do I choose the right ETP48200-C5B7002 for my system?

Verify host model, electrical ratings, interface types and protocol requirements. Share your system details with RICEWIND and we will compare compatible options across brands.

### Is ETP48200-C5B7002 compatible with my existing equipment?

Compatibility depends on power input, pinout signals and rack mounting specifications. Our engineers can review interfaces and integration details before you order.

### Does RICEWIND provide international shipping for ETP48200-C5B7002?

Yes. RICEWIND ships worldwide; freight options depend on destination, weight and urgency. Contact us for a shipping quote to your site.

### What warranty and after-sales support are available for ETP48200-C5B7002?

Warranty follows the manufacturer policy for your region. RICEWIND provides technical documentation, firmware guidance and engineer-level assistance throughout the project.

### Does RICEWIND supply ETP48200-C5B7002?

Yes. RICEWIND supplies ETP48200-C5B7002 with MOQ from 1 unit; in-stock items dispatch within 24-48 hours with worldwide shipping.

### Is there a cross-reference or equivalent for ETP48200-C5B7002?

RICEWIND maintains a cross-reference database covering leading telecom and energy infrastructure brands. Contact us for the direct equivalent of ETP48200-C5B7002.

### How should the DC output and battery cable cross-sections be sized when the ETP48200-C5B7002 operates at its full 200A capacity?

At full 200A load with standard telecom voltage drop limits (total two-way DC bus drop ≤0.5V) at 40°C ambient, multiconductor flame-retardant copper cables are recommended. The battery main feed requires at least 70mm² to 95mm²; if configured with two dual-string 100A battery banks, each string requires 35mm² to 50mm². The total DC load output bus requires 70mm² to 95mm². Final cross-sections must always be validated against the path loop length using S = (2 \* L \* I) / (γ \* ΔU).

### What are the recommended engineering threshold settings for Load Low Voltage Disconnect (LLVD) and Battery Low Voltage Disconnect (BLVD) in the SMU02C controller?

For standard -48V VRLA battery systems, best practice is to set LLVD to trigger between -45.0VDC and -45.5VDC to shed non-critical loads during power failure. BLVD must be set strictly between -43.2VDC and -44.0VDC (1.80V to 1.83V per cell) to prevent terminal deep discharge. If LiFePO4 lithium batteries are deployed, configure LLVD around -46.0VDC and BLVD to -44.5VDC ~ -45.0VDC, ideally synchronizing actions with the BMS via RS485 or CAN protocols.

### How does the battery temperature compensation coefficient operate, and what occurs if the temperature sensor fails or is disconnected?

The SMU02C dynamically adjusts float voltage based on 25°C (standard coefficient: -72mV/°C to -120mV/°C across a 24-cell VRLA bank). As temperature rises, voltage is decreased to prevent thermal runaway; as it drops, voltage is boosted to guarantee a 100% state of charge. If the probe disconnects or fails, the controller raises a sensor fault alarm, deactivates compensation, and clamps the system float voltage strictly to the default nominal 25°C reference (typically -53.5VDC) to safeguard the cells against bulging or chronic undercharging.

### What is the operating principle of autonomous active current sharing between rectifiers, and how should an engineer troubleshoot an excessive current sharing imbalance?

Huawei rectifiers utilize autonomous digital CAN-bus active current sharing. Rectifiers exchange real-time load data over the CAN bus and dynamically trim internal voltage references to achieve an imbalance of less than ±5% between 50% and 100% rated load. If severe current divergence occurs: check for CAN communication alarms on the SMU02C; inspect the module gold-finger backplane pins for dust or pin damage; and review individual voltage calibrations in the SMU interface, recalibrating the bus or replacing the defective rectifier if deviation persists.