# Huawei ETP48200-C5B7 Embedded DC Power Subrack (48V 200A 5U)

RICEWIND · Huawei

https://ricewind.com/en/products/etp48200-c5b7

Model: ETP48200-C5B7

Huawei ETP48200-C5B7 is a 5U standard embedded DC power system (200A) equipped with SMU02 LCD controller, 4 × 50A rectifier slots, and comprehensive surge protection.

## What this product is

Telecom-grade power infrastructure module designed for HUAWEI power architecture.

## What problem it solves

Eliminates grid power anomalies and brownout hazards across mission-critical communication centers.

## Who and where it is for

Cellular wireless sites, optical broadband hubs, edge computing racks, and industrial private networks.

## Core advantages

- Wide input voltage range (85-300VAC) ensures high availability and uninterrupted power in harsh grid environments.
- Supports 4x R4850G2/G6 rectifier slots for flexible -48V DC 200A capacity expansion and N+1 redundancy.
- Compatible with SMU02B/SMU02C intelligent controllers, offering precise management, LCD interface, and SNMP remote O&M.
- Compact 5U height design with an ultra-wide operating temperature (-40°C to +65°C) for demanding edge sites.

## Applications

- Telecom 4G/5G macro cellular base stations and distributed remote power sites
- Enterprise-grade cloud data center mission-critical -48V DC power distribution lineups
- Utility power grid dispatch centers and high-voltage substation DC switchgear rooms
- Railway transit signaling, automated train control, and communications equipment rooms

## Technical specifications

- AC input voltage range: 220V/380V compatible (85~300VAC)
- Rectifier Module Slots: 4 × R4850G2 / R4850G6 (50A)
- Overall System Efficiency: Up to 96.2% (Gold Standard)
- DC output voltage range: -48VDC (-42V ~ -58V)
- Acoustic Noise: ≤ 55 dBA (at 25°C ambient load)
- Ingress Protection Rating: IP20 (Indoor Dust & Finger Proof)
- Operating Temperature Range: -40°C ~ +65°C
- Dimensions: 222 (5U) × 442 × 360 mm
- Dielectric Withstand Voltage: 3000VAC Input to Ground (\< 5mA)
- System Monitoring Controller: SMU02B / SMU02C intelligent monitoring unit

## Frequently asked questions

### Is ETP48200-C5B7 compatible with existing batteries, generators, and rectifiers?

Compatibility depends on DC bus voltage, telemetry protocols, and mechanical form factors. Describe your existing site setup and RICEWIND engineers can verify integration feasibility before you order.

### How is ETP48200-C5B7 delivered? Does RICEWIND provide international shipping?

Power systems are packed in heavy-duty export-standard wooden crates for sea or air transport. RICEWIND ships worldwide — contact us to confirm inventory, freight options, and delivery schedules.

### What warranty and engineering support are available for ETP48200-C5B7?

Warranty follows the manufacturer policy for the specific configuration. RICEWIND supports wiring schematics, remote commissioning guidance, spare parts, and engineer-level technical assistance.

### Does RICEWIND supply ETP48200-C5B7?

Yes. RICEWIND supplies ETP48200-C5B7 with MOQ from 1 system; in-stock units dispatch within 24-48 hours with global logistics coverage.

### Is there a cross-reference or equivalent replacement for ETP48200-C5B7?

RICEWIND maintains a cross-reference matrix covering Huawei, Vertiv, Eltek, and ZTE telecom power systems. Contact us for direct equivalents and expansion options for ETP48200-C5B7.

### How do I plan and configure ETP48200-C5B7 for my telecom site?

Consider total DC load, N+1 redundancy, battery autonomy backup time, surge protection, and cabinet footprint. Share your project requirements with RICEWIND and we will propose a matched configuration.

### What are the core electrical output specifications, AC input adaptability, and conversion efficiency of the Huawei ETP48200-C5B7?

The Huawei ETP48200-C5B7 is a 5U embedded telecom DC power subrack designed for a nominal system capacity of 200A (up to 12kW continuous output when fully populated with 4x 50A rectifiers). It operates at a nominal -48V DC output, adjustable between -42V DC and -58V DC. The AC input supports a versatile 220V/380V compatible architecture (single-phase 85–300VAC or three-phase input), delivering 100% full-load output between 176–300VAC (with linear derating from 176VAC down to 85VAC). Utilizing Huawei R4850G2 or ultra-efficient R4850G6 rectifier modules, the system achieves a peak efficiency \>96%, power factor (PF) ≥ 0.99, and THD ≤ 5%. Controlled via the SMU02B/SMU02C intelligent monitoring unit, voltage measurement accuracy stays within ±0.5%.

### What are the rectifier compatibility, hot-swap capabilities, and DC distribution expansion mechanisms of the ETP48200-C5B7 subrack?

The ETP48200-C5B7 chassis features 4 standardized 50A rectifier slots, natively compatible with Huawei R4850G2, R4850N2, and high-efficiency R4850G6 modules with zero-downtime hot-swappability. Modules communicate via high-speed CAN bus for active digital current sharing with an imbalance rate under ±5%, supporting N+1 redundancy and smart module hibernation for energy optimization. On the DC distribution side, it integrates 2 heavy-duty battery input branches (typically fused at 125A–160A) along with multi-channel load branches routed through Load Low Voltage Disconnect (LLVD) and Battery Low Voltage Disconnect (BLVD) contactors, ensuring prioritized tiered shedding for critical network nodes.

### How does the system perform regarding extreme environmental tolerance, surge protection ratings, and Low Voltage Disconnect (LVD) battery management?

Engineered for harsh telecom edge sites, the ETP48200-C5B7 operates reliably across -40°C to +65°C (with intelligent derating above +45°C) and 5% to 95% non-condensing relative humidity. It integrates robust Class C AC surge protection (differential mode 20kA, common mode 40kA, 8/20μs) and DC side SPD rated at 10/20kA. System battery safety is governed by hardware dual LVD contactors: LLVD prioritizes core telecom gear by shedding auxiliary loads first, while BLVD disconnects the battery string at the safety threshold (e.g., 43.2V) to prevent irreversible deep discharge. Rectifier modules utilize intelligent step-less speed-regulated fans to ensure thermal stability and reduce dust ingress.

Content updated: 2026-09-11T00:57:37.117Z