# Emerson R48-5800E High-Capacity High-Efficiency Telecom Switch-Mode Rectifier (-48V 120A 5800W)

RICEWIND · Emerson

https://ricewind.com/en/products/emerson-r48-5800e-b30

Model: R48-5800E

The Emerson R48-5800E is a carrier-grade, ultra-high-capacity switch-mode rectifier module engineered for mission-critical -48V DC telecommunication and data infrastructure. Delivering a nominal output of -48V DC (adjustable from -42V to -58V DC) with an exceptional maximum output current of 120A and rated power of 5800W, it operates at a peak conversion efficiency exceeding 96.0% with class-leading power density.

## What this product is

Architecturally, the R48-5800E integrates a wide-input (85V AC to 300V AC) single/three-phase-compatible active PFC front-end stage that boosts incoming AC to a regulated high-voltage DC link with input THD under 5%. The secondary power stage employs an isolated zero-voltage-switching (ZVS) LLC resonant converter with synchronous rectification to yield low-noise, tightly regulated -48V DC power. Autonomous hardware-level active current sharing and robust internal monitoring logic guarantee seamless parallel expansion.

## What problem it solves

It resolves footprint congestion, excessive thermal dissipation, and erratic power disruptions in high-density telecom central offices. By offering an expansive input tolerance and automatic power derating under low-voltage conditions, it prevents nuisance dropouts caused by voltage sags and rolling brownouts. Advanced self-locking over-voltage protection (OVP) and thermal foldback circuitry protect critical battery strings and radio equipment from overstress and thermal runaway.

## Who and where it is for

Ideal for major telecom central offices (COs), 5G macro base station hub sites, enterprise hyperscale data centers requiring -48V DC distribution, large-scale optical transmission transport nodes, and industrial power plants where superior availability and low PUE metrics are paramount.

## Core advantages

- Ultra-high power density delivering 5800W capacity, optimizing space in telecom central offices.
- Peak efficiency exceeding 96.0%, drastically reducing operating energy costs for high-load hubs.
- Wide AC input range (85V-300V) with staged derating ensures robust performance in unstable grids.
- Integrated high-speed CAN interface and smart thermal protection guarantee live hot-plug reliability.

## Applications

- National telecom central office NetSure-series high-capacity DC power bays
- 5G wireless baseband processing units (BBU) and high-power macro distributed radio hubs
- Hyperscale datacenter -48V server rack arrays and hybrid optical cross-connect rooms
- Railway traction substations and utility mission-critical supervisory communication grids

## Technical specifications

- Maximum Output Current: 120A
- Rated Output Power: 5800W
- AC Input Voltage: 85V AC ~ 300V AC (3-Phase / 1-Phase Compatible)
- Rated Output Voltage: -48VDC (-42V ~ -58V)
- Maximum Efficiency: ≥ 96.0%
- Operating Temperature Range: -40°C ~ +75°C
- Cooling System: Forced Air Cooling with Intelligent Speed Fan
- Hot-Swappable Support: Yes (Live Hot-Pluggable / Plug-and-Play without Power Interruption)

## Frequently asked questions

### How do I select R48-5800E for my power system?

Check output voltage, module power rating, efficiency class and compatibility with your existing rectifier shelf or controller. RICEWIND can verify fitment and propose the right quantity.

### Is R48-5800E compatible with my existing system?

Compatibility depends on the rectifier shelf, controller and communication protocol. Send your current system model to RICEWIND and our engineers will confirm which modules fit.

### Does RICEWIND provide international shipping for R48-5800E?

Yes. Power modules and systems are packed in anti-static, export-standard crates and shipped worldwide. Delivery time and freight options depend on stock and destination — contact RICEWIND for quotes and lead times.

### What warranty and technical support apply to R48-5800E?

Warranty follows the manufacturer's policy for the specific equipment. RICEWIND supports testing guidance, replacement requests, spare parts and technical coordination per order terms.

### Does RICEWIND supply R48-5800E from stock?

Yes. RICEWIND supplies R48-5800E from verified stock with MOQ from 1 piece; in-stock units dispatch within 24-48 hours with global express air and sea freight.

### Is there a cross-reference or equivalent for R48-5800E?

RICEWIND maintains a comprehensive cross-reference chart covering Huawei, Vertiv (Emerson), Eltek, ZTE and Delta 48V telecom rectifiers. Contact us for the direct equivalent of R48-5800E.

### How does the R48-5800E derate output power when the AC line voltage drops below 176V AC?

The module maintains its full 5800W output capacity within the nominal 176V AC to 300V AC window. When input voltage drops between 85V AC and 176V AC, the onboard DSP initiates proportional linear derating to cap input current and protect primary-side switching elements. At the minimum 85V AC threshold, the rectifier reliably provides approximately 40% to 50% of rated capacity rather than shutting down, ensuring uninterrupted DC bus operation.

### What primary root causes trigger a solid yellow fault LED on the R48-5800E front panel?

A continuous yellow LED denotes non-fatal protection mode or abnormal operating conditions. Chief causes include: AC input voltage out-of-range (\<85V AC or \>305V AC), severe intake air restriction triggering over-temperature protection (OTP), fan stall/speed deviation detected by tachometer feedback, or a deliberate remote-disable command sent by the central controller. The module automatically recovers once operating parameters return within safe limits.

### What is the correct field procedure when live hot-swapping an R48-5800E in an active power bay?

Before insertion, inspect the rear blind-mate connector for debris, pin deformation, or arcing damage. Slide the unit smoothly into the designated shelf guide rails until the floating connector engages, then firmly close and latch the extraction handle to engage mechanical locking. The internal soft-start pre-charge circuit prevents inrush arcing. The system controller (e.g., M830B) will automatically detect the unit over the CAN bus, verify firmware, and calibrate load sharing within 10 to 30 seconds.

### What happens to the R48-5800E if the CAN communication link to the system controller is severed?

If CAN communication is lost, the R48-5800E shifts smoothly into autonomous fail-safe mode. It drops dynamic software regulation and defaults to a pre-programmed hardware float voltage (typically -53.5V DC). Internal analog droop circuitry maintains autonomous current sharing among all online rectifiers with an imbalance margin of less than ±5%, preventing system collapse during communication link dropouts.