# Eltek Flatpack2 48/2000 WOR HE High Efficiency Rectifier Module (241115.805)

RICEWIND · Eltek

https://ricewind.com/en/products/eltek-flatpack2-241115-805

Model: Flatpack2 48/2000 WOR HE (241115.805)

SKU: ELT-ELTEK-FLATPACK2-241115-8-BA7F1F

The Eltek Flatpack2 48/2000 WOR HE (241115.805) is a carrier-grade, hot-pluggable switch-mode rectifier module delivering 2000W of regulated 48VDC power across a wide operating range.

## What this product is

A switch-mode AC/DC power conversion module utilizing advanced resonant topology to convert global AC mains into stable -48V DC power, engineered for parallel operation within Eltek power shelves managed by Smartpack controllers.

## What problem it solves

Eliminates premature power equipment failure caused by unstable utility grids, reduces operational expenditure through ultra-low thermal dissipation, and accommodates wide DC bus charging profiles for advanced battery chemistries.

## Who and where it is for

Cellular macro base stations, central offices, edge data enclosures, and mission-critical industrial DC backup plants.

## Core advantages

- Advanced soft-switching high-frequency topology achieves peak efficiency ≥96.5%, significantly lowering telecom site PUE.
- Ultra-wide AC input range of 85–300 VAC ensures uninterrupted power supply and resilience against severe grid fluctuations.
- Flexible output voltage range from 43.5 to 57.6 VDC perfectly accommodates legacy telecom loads and advanced energy storage.
- Robust -40°C to +75°C operating range with smart temperature-controlled fans ensures high-reliability N+1 redundancy.

## Applications

- Telecom 4G/5G macro cellular base stations and distributed remote power sites
- Enterprise-grade cloud data center mission-critical -48V DC power distribution lineups
- Utility power grid dispatch centers and high-voltage substation DC switchgear rooms
- Railway transit signaling, automated train control, and communications equipment rooms

## Technical specifications

- Nominal DC Output Voltage: -48VDC (-42V ~ -58V)
- AC Input Voltage: 85VAC ~ 300VAC (Wide Range)
- Operating Efficiency Rating: ≥96.5%
- Operating Temperature Range: -40°C ~ +75°C
- Rated Output Power Capacity: 2000W (41.7A @ 48VDC)
- Cooling System: Internal Temperature-Controlled Intelligent Variable Speed Fan
- Overall System Efficiency: Up to 96.2% (Gold Standard)
- Acoustic Noise: ≤ 55 dBA (at 25°C ambient load)
- Ingress Protection Rating: IP20 (Indoor Dust & Finger Proof)
- Dielectric Withstand Voltage: 3000VAC Input to Ground (\< 5mA)

## Frequently asked questions

### How do I select Flatpack2 48/2000 WOR HE (241115.805) for my power system?

Check output voltage, module power rating, efficiency class and compatibility with your existing rectifier shelf or controller. RICEWIND can verify fitment and propose the right quantity.

### Is Flatpack2 48/2000 WOR HE (241115.805) compatible with my existing system?

Compatibility depends on the rectifier shelf, controller and communication protocol. Send your current system model to RICEWIND and our engineers will confirm which modules fit.

### Does RICEWIND provide international shipping for Flatpack2 48/2000 WOR HE (241115.805)?

Yes. Power modules and systems are packed in anti-static, export-standard crates and shipped worldwide. Delivery time and freight options depend on stock and destination — contact RICEWIND for quotes and lead times.

### What warranty and technical support apply to Flatpack2 48/2000 WOR HE (241115.805)?

Warranty follows the manufacturer's policy for the specific equipment. RICEWIND supports testing guidance, replacement requests, spare parts and technical coordination per order terms.

### Does RICEWIND supply Flatpack2 48/2000 WOR HE (241115.805) from stock?

Yes. RICEWIND supplies Flatpack2 48/2000 WOR HE (241115.805) from verified stock with MOQ from 1 piece; in-stock units dispatch within 24-48 hours with global express air and sea freight.

### Is there a cross-reference or equivalent for Flatpack2 48/2000 WOR HE (241115.805)?

RICEWIND maintains a comprehensive cross-reference chart covering Huawei, Vertiv (Emerson), Eltek, ZTE and Delta 48V telecom rectifiers. Contact us for the direct equivalent of Flatpack2 48/2000 WOR HE (241115.805).

### What engineering condition is indicated when the front yellow LED is steady or flashing, and how should it be diagnosed?

A steady yellow LED indicates a secondary alarm or non-critical protection mode: AC input voltage is outside standard thresholds (\<85VAC or \>300VAC), or the module has entered thermal derating due to high ambient temperature or obstructed heatsinks. A flashing yellow LED indicates a loss of CAN bus communication between the rectifier and the system controller (Smartpack/Smartpack2). Engineering diagnostic steps: 1) Verify AC input voltage at the backplane terminals with a true-RMS multimeter; 2) Inspect front intake grilles and internal airflow paths for thermal choking; 3) Re-seat the module firmly into the power shelf to ensure full engagement of the rear connector pins and inspect CAN bus termination and controller communication status.

### A steady red LED signifies a module shutdown/lockout. What are the primary root causes, and how do you differentiate between internal hardware failure and external faults?

A solid red LED indicates a critical shutdown or hardware lockout. Primary causes: 1) DC Output Overvoltage Protection (OVP) tripped (\>59-60VDC threshold); 2) Catastrophic internal overheating; 3) Internal power stage failure (shorted PFC/LLC MOSFETs, blown primary/secondary internal fuses); 4) Critical cooling fan failure or tachometer stall. Isolation method: Power down the AC circuit, remove the suspect module, and insert it into a known-good slot on another subrack. Re-apply AC power: If the red LED illuminates immediately and the fan fails its initial rev test, the failure is internal (module replacement required). If the module boots up with a green LED and sustains nominal load, inspect the original shelf backplane for bus shorts, load surges, or invalid OVP configuration in the Smartpack controller.

### What engineering root causes lead to severe load-sharing imbalance in parallel multi-module systems, and how should it be rectified?

Flatpack2 utilizes an active digital current-sharing scheme managed via CAN bus communications, maintaining load imbalance within ±5% of rated current. If a module delivers significantly higher/lower current or drops to zero while others carry the load, root causes include: 1) CAN bus interruption or frame packet loss, forcing the rogue module into autonomous fallback regulation without reference synchronization; 2) Unequal DC contact resistance caused by oxidised backplane connector blades; 3) Firmware version discrepancies or duplicate CAN address mappings; 4) One module experiencing thermal throttling due to local fan degradation. Corrective steps: 1) Audit the Smartpack controller log to verify all rectifiers show active online status without bus communication errors; 2) Reseat suspect units to clean connector interfaces; 3) Confirm uniform firmware versions and verify individual rectifier temperature sensors.

### If a rectifier frequently reports AC input under/overvoltage alarms and undergoes cyclical restarts, what electrical parameters must be investigated?

Cyclical AC alarm trips typically indicate excessive line impedance, a floating/loose neutral, or generator supply instability under transient step loads. Key engineering checks: 1) Dynamic Voltage Drop: Measure AC input terminals while the system shifts from zero to maximum load current. High line impedance or undersized cables cause terminal voltage to collapse below the 85VAC threshold under load, dropping out the module. Once disconnected, the line voltage recovers and the module attempts to restart, creating an endless cycling loop; 2) Neutral-to-Earth Potential: A loose neutral conductor creates neutral point float, generating severe phase overvoltage (\>300VAC) or severe sag depending on phase loading; 3) Total Harmonic Distortion (THD): High generator voltage distortion can corrupt internal zero-crossing detection. Action: Verify cable cross-section sizing, torque all terminals, and inspect upstream ATS contact resistance.

Content updated: 2026-09-14T15:01:25.804Z