# Eltek Flatpack2 24/2000 HE High Efficiency Rectifier Module (241115.205)

RICEWIND · Eltek

https://ricewind.com/en/products/eltek-flatpack2-241115-205

Model: Flatpack2 24/2000 HE (241115.205)

SKU: ELT-ELTEK-FLATPACK2-241115-2-444267

The Eltek Flatpack2 24/2000 HE (241115.205) is a carrier-grade 24VDC, 2000W switch-mode power supply designed for mission-critical telecom and industrial installations.

## What this product is

A compact 1U hot-pluggable AC-to-DC power conversion cassette incorporating patented soft-switching resonant bridge topologies, communicating digitally via an integrated CAN interface with Smartpack controllers.

## What problem it solves

Eliminates excessive thermal dissipation and high operational cooling overheads while maintaining uninterrupted DC power across unstable utility grids prone to deep sags and extreme voltage surges.

## Who and where it is for

Wireless base stations, broadband telecom access nodes, offshore platforms, railway signaling, and industrial control systems requiring redundant 24VDC rails.

## Core advantages

- Utilizes a fully digital DSP topology and soft-switching resonant architecture, achieving up to 95.5% efficiency to significantly minimize thermal dissipation.
- Supports an ultra-wide AC input range of 85-300VAC, maintaining a stable 2000W full-load output under unstable grids and harsh EMC conditions.
- Features a 1U compact hot-swappable design combined with autonomous active current sharing for zero-downtime scalability and effortless maintenance.
- Engineered for extreme environments with an operating temperature of -40°C to +75°C and intelligent front-to-back forced air cooling.

## Applications

- Telecom 4G/5G macro cellular base stations and distributed remote power sites
- Enterprise-grade cloud data center mission-critical -48V DC power distribution lineups
- Utility power grid dispatch centers and high-voltage substation DC switchgear rooms
- Railway transit signaling, automated train control, and communications equipment rooms

## Technical specifications

- Rated Output Power Capacity: 2000W (83.3A @ 24VDC)
- Operating Temperature Range: -40°C ~ +75°C
- AC Input Voltage: 85VAC ~ 300VAC
- Nominal DC Output Voltage: -48VDC (-42V ~ -58V)
- Operating Efficiency Rating: ≥95.5%
- Cooling System: Temperature-Controlled Front-to-Rear Air Cooling
- Overall System Efficiency: Up to 96.2% (Gold Standard)
- Acoustic Noise: ≤ 55 dBA (at 25°C ambient load)
- Ingress Protection Rating: IP20 (Indoor Dust & Finger Proof)
- Dielectric Withstand Voltage: 3000VAC Input to Ground (\< 5mA)

## Frequently asked questions

### How do I select Flatpack2 24/2000 HE (241115.205) for my power system?

Check output voltage, module power rating, efficiency class and compatibility with your existing rectifier shelf or controller. RICEWIND can verify fitment and propose the right quantity.

### Is Flatpack2 24/2000 HE (241115.205) compatible with my existing system?

Compatibility depends on the rectifier shelf, controller and communication protocol. Send your current system model to RICEWIND and our engineers will confirm which modules fit.

### Does RICEWIND provide international shipping for Flatpack2 24/2000 HE (241115.205)?

Yes. Power modules and systems are packed in anti-static, export-standard crates and shipped worldwide. Delivery time and freight options depend on stock and destination — contact RICEWIND for quotes and lead times.

### What warranty and technical support apply to Flatpack2 24/2000 HE (241115.205)?

Warranty follows the manufacturer's policy for the specific equipment. RICEWIND supports testing guidance, replacement requests, spare parts and technical coordination per order terms.

### Does RICEWIND supply Flatpack2 24/2000 HE (241115.205) from stock?

Yes. RICEWIND supplies Flatpack2 24/2000 HE (241115.205) from verified stock with MOQ from 1 piece; in-stock units dispatch within 24-48 hours with global express air and sea freight.

### Is there a cross-reference or equivalent for Flatpack2 24/2000 HE (241115.205)?

RICEWIND maintains a comprehensive cross-reference chart covering Huawei, Vertiv (Emerson), Eltek, ZTE and Delta 48V telecom rectifiers. Contact us for the direct equivalent of Flatpack2 24/2000 HE (241115.205).

### When the controller reports 'Module Missing' or the yellow LED blinks persistently, how should CAN bus communication failures be isolated?

A blinking yellow LED indicates lost CAN communication with the system controller. Execute the following troubleshooting sequence: 1) Physical contact: Remove the module and inspect the rear blind-mate connector for bent pins, dust, or cold solder joints on the backplane slot. 2) Termination resistance check: Power down the system or isolate the CAN line, then measure resistance between CAN\_H and CAN\_L with a multimeter. The measurement across the system must read approximately 60Ω (two 120Ω terminating resistors in parallel). A reading of 120Ω indicates an open terminator, while infinity indicates a broken CAN bus run. 3) Controller polling: If replacing a module, re-seat the cassette and run the 'Re-map Rectifiers' or 'Find New Units' utility on the Smartpack interface to re-assign hardware node IDs.

### When a high-temperature alarm triggers thermal derating, how do you diagnose fan tachometer performance and optimize thermal management?

The Flatpack2 24/2000 HE operates at full 2000W output up to 55°C, derating linearly down to shutoff at 75°C. If derating occurs prematurely under moderate ambient conditions: 1) Airflow obstructions: Check the front intake grilles and rear exhaust vents. Accumulations of particulate matter must be cleaned using dry, compressed air blown front-to-back to clear internal heatsink fins. 2) Fan tachometer feedback: The internal brushless DC fan provides a hall-effect tachometer pulse to the internal DSP. Access the controller diagnostic screen to inspect live RPM readings. If RPM falls below expected PWM curves (\<2500 RPM under load), the fan bearings are compromised or mechanically stalled. 3) Replacement: Detach the front bezel, disconnect the proprietary 4-wire fan harness, and replace the fan assembly with an OEM-spec tachometer-equipped unit.

### What are the output power derating characteristics and protection mechanisms of this module during severe AC brownouts (85–185 VAC) and grid surges?

The Flatpack2 24/2000 HE features an active PFC boost stage designed to sustain grid irregularities: 1) Low AC derating profile: Full rated power of 2000W (83.3A @ 24VDC) is delivered from 185 to 275/300 VAC. Between 85 and 185 VAC, the DSP limits output power linearly proportional to input voltage to prevent primary-stage thermal runaway, delivering approximately 850W–900W at 85 VAC. Below 85 VAC, an AC undervoltage shutdown is executed. 2) Surge and high-line behavior: Equipped with high-energy MOVs and varistor arrays, the unit safely tolerates continuous AC line swells up to 300 VAC. Above 305 VAC, the Overvoltage Shutdown (OVS) circuit interrupts primary switching within 10 milliseconds, automatically recovering and restarting once input mains return to nominal specifications.

Content updated: 2026-09-15T02:10:18.658Z