# Eltek Flatpack2 48/2000 HE Rectifier Module (241115.100)

RICEWIND · Eltek

https://ricewind.com/en/products/eltek-flatpack2-241115-100

Model: Eltek Flatpack2 48/2000 HE (241115.100)

SKU: ELTEK-FP2-48-2000-HE-241115-100

Industry-standard 48V 2000W telecom rectifier delivering 96.5% high efficiency, wide AC input range, and intelligent CAN bus current sharing.

## What this product is

Industry-standard 48V 2000W telecom rectifier delivering 96.5% high efficiency, wide AC input range, and intelligent CAN bus current sharing.

## What problem it solves

The Eltek Flatpack2 48/2000 HE (PN: 241115.100) is a hallmark of telecom power engineering. Boasting over 96.5% power conversion efficiency, hot-pluggable architecture, and digital CAN bus control, it drastically reduces operational power loss in data and telecom rooms.

## Who and where it is for

Industry-standard 48V 2000W telecom rectifier delivering 96.5% high efficiency, wide AC input range, and intelligent CAN bus current sharing.

## Core advantages

- Heavy-duty industrial construction engineered for demanding environments
- High power efficiency topology reducing heat dissipation and operational costs
- Full digital communication integration for centralized monitoring and telemetry
- Comprehensive multi-stage protection against overvoltage, overcurrent, and surges
- Compact modular footprint maximizing equipment density and site utilization
- Carrier-grade durability certified for high Mean Time Between Failures (MTBF)

## Applications

- Cellular 4G/5G macro sites and distributed antenna coverage networks
- Mission-critical data center server rooms and edge computing facilities
- Telecom exchange DC power plant and backup distribution systems
- Remote industrial telemetry in energy, mining, and railway corridors
- Smart grid substation communications and automated power infrastructure
- Outdoor harsh-environment telecom installations on towers and rooftops

## Technical specifications

- AC Input Voltage: 85V to 300V AC (rated 185V to 275V AC)
- DC Output Voltage: -48VDC (-42V ~ -58V)
- Rated Output Power: 2000W (maximum output current 41.7A @ 48V)
- Power Conversion Efficiency: ≥ 96.5%
- Communication & Current Sharing: Internal digital CAN bus auto load sharing (\<5%)
- Official Part Number: 241115.100 (Official global Eltek part number)
- Overall System Efficiency: Up to 96.2% (Gold Standard)
- Ingress Protection Rating: IP20 (Indoor Dust & Finger Proof)
- Acoustic Noise: ≤ 55 dBA (at 25°C ambient load)
- Dielectric Withstand Voltage: 3000VAC Input to Ground (\< 5mA)

## Frequently asked questions

### How do I select Eltek Flatpack2 48/2000 HE (241115.100) for my power system?

Check output voltage, module power rating, efficiency class and compatibility with your existing rectifier shelf or controller. RICEWIND can verify fitment and propose the right quantity.

### Is Eltek Flatpack2 48/2000 HE (241115.100) compatible with my existing system?

Compatibility depends on the rectifier shelf, controller and communication protocol. Send your current system model to RICEWIND and our engineers will confirm which modules fit.

### Does RICEWIND provide international shipping for Eltek Flatpack2 48/2000 HE (241115.100)?

Yes. Power modules and systems are packed in anti-static, export-standard crates and shipped worldwide. Delivery time and freight options depend on stock and destination — contact RICEWIND for quotes and lead times.

### What warranty and technical support apply to Eltek Flatpack2 48/2000 HE (241115.100)?

Warranty follows the manufacturer's policy for the specific equipment. RICEWIND supports testing guidance, replacement requests, spare parts and technical coordination per order terms.

### Does RICEWIND supply Eltek Flatpack2 48/2000 HE (241115.100) from stock?

Yes. RICEWIND supplies Eltek Flatpack2 48/2000 HE (241115.100) from verified stock with MOQ from 1 piece; in-stock units dispatch within 24-48 hours with global express air and sea freight.

### Is there a cross-reference or equivalent for Eltek Flatpack2 48/2000 HE (241115.100)?

RICEWIND maintains a comprehensive cross-reference chart covering Huawei, Vertiv (Emerson), Eltek, ZTE and Delta 48V telecom rectifiers. Contact us for the direct equivalent of Eltek Flatpack2 48/2000 HE (241115.100).

### Why does the front-panel status LED flash yellow after inserting the Flatpack2 module into a power shelf?

A flashing yellow LED typically indicates that the module is negotiating dynamic CAN bus address assignment with the Smartpack controller or undergoing a battery test. It turns solid green once configuration settles.

### Does the Flatpack2 2000W rectifier shut down when the AC input voltage drops below 185VAC?

No, it does not shut down. The rectifier features intelligent linear derating, sustaining safe output power from 85VAC to 185VAC without tripping or disconnecting telecom loads during brownouts.

### How to safely remove a Flatpack2 2000W rectifier if it jams or binds inside an aging power shelf?

Never pry the plastic handle with metal tools. Depress the top locking catch fully to release the rear mechanical interlock and pull horizontally along card guides. Dry contact lubricant can be applied to guides if aged connectors bind.

### What hardware failure causes a solid red alarm LED accompanied by internal cooling fan running at maximum speed?

This indicates internal Over-Voltage Protection (OVP) latching or critical PFC heatsink over-temperature. Disconnect AC power for 5 minutes to discharge capacitors. If the red LED persists upon restart, power stage MOSFETs have shorted.

Content updated: 2026-09-14T11:26:27.026Z