# Eltek I/O CAN Node Controller (242100.120)

RICEWIND · Eltek

https://ricewind.com/en/products/eltek-can-node-242100-120

Model: I/O CAN Node Controller (242100.120)

The Eltek 242100.120 is an industrial-grade CAN bus expansion module engineered to extend analog monitoring, digital sensing, and relay control for Smartpack supervisory systems.

## What this product is

An intelligent peripheral node designed for carrier-grade DC power systems, communicating over dual RJ45 CAN bus ports to convert physical site parameters into standardized digital telemetry for centralized controllers.

## What problem it solves

Eliminates complex point-to-point cable bundles across distributed power cabinets, prevents signal attenuation over long instrumentation lines, and expands monitoring capacity for complex battery banks.

## Who and where it is for

Cellular telecom sites, fixed-line switching centers, railway signaling substations, utility HV/MV DC panels, and industrial hybrid microgrids.

## Core advantages

- Distributed CAN bus architecture significantly reduces long-distance cabling and wiring complexity in telecom sites.
- Wide operating voltage (18-60VDC) and -40°C to +70°C temperature range ensure reliability in harsh industrial environments.
- Integrated multi-channel digital inputs (DI) and relay outputs (DO) enable precise environmental and status monitoring.
- Electrically isolated CANopen communication effectively suppresses ground potential drift and enhances noise immunity.

## Applications

- Telecom 4G/5G macro cellular base stations and distributed remote power sites
- Enterprise-grade cloud data center mission-critical -48V DC power distribution lineups
- Utility power grid dispatch centers and high-voltage substation DC switchgear rooms
- Railway transit signaling, automated train control, and communications equipment rooms

## Technical specifications

- Chassis Form Factor: 19-Inch Rackmount
- DC Operating Voltage Range: 18VDC ~ 60VDC V DC
- I/O Acquisition Channels: Multi-Channel Digital Inputs (DI) + Relay Alarm Outputs (DO)
- Operating Temperature Range: -40°C ~ +75°C
- Status Indicator: Power Indicator + Dual-Color CAN Communication Status LED
- Bus Interface: CAN Fieldbus Isolated Communication
- Overall System Efficiency: Up to 96.2% (Gold Standard)
- Acoustic Noise: ≤ 55 dBA (at 25°C ambient load)
- Ingress Protection Rating: IP20 (Indoor Dust & Finger Proof)
- Dielectric Withstand Voltage: 3000VAC Input to Ground (\< 5mA)

## Frequently asked questions

### How do I select I/O CAN Node Controller (242100.120) for my power system?

Check output voltage, module power rating, efficiency class and compatibility with your existing rectifier shelf or controller. RICEWIND can verify fitment and propose the right quantity.

### Is I/O CAN Node Controller (242100.120) compatible with my existing system?

Compatibility depends on the rectifier shelf, controller and communication protocol. Send your current system model to RICEWIND and our engineers will confirm which modules fit.

### Does RICEWIND provide international shipping for I/O CAN Node Controller (242100.120)?

Yes. Power modules and systems are packed in anti-static, export-standard crates and shipped worldwide. Delivery time and freight options depend on stock and destination — contact RICEWIND for quotes and lead times.

### What warranty and technical support apply to I/O CAN Node Controller (242100.120)?

Warranty follows the manufacturer's policy for the specific equipment. RICEWIND supports testing guidance, replacement requests, spare parts and technical coordination per order terms.

### Does RICEWIND supply I/O CAN Node Controller (242100.120) from stock?

Yes. RICEWIND supplies I/O CAN Node Controller (242100.120) from verified stock with MOQ from 1 piece; in-stock units dispatch within 24-48 hours with global express air and sea freight.

### Is there a cross-reference or equivalent for I/O CAN Node Controller (242100.120)?

RICEWIND maintains a comprehensive cross-reference chart covering Huawei, Vertiv (Emerson), Eltek, ZTE and Delta 48V telecom rectifiers. Contact us for the direct equivalent of I/O CAN Node Controller (242100.120).

### How should the physical bus and termination resistors be verified when the Smartpack controller reports a 'CAN Node Disconnected' fault for this module?

Power down or isolate the communication segment and measure the DC loop resistance between CAN\_H (pin 4) and CAN\_L (pin 5) using a calibrated multimeter. A properly terminated bus must measure approximately 60 Ohms, representing two 120-Ohm end-of-line resistors in parallel. If the reading is ~120 Ohms, one end-of-line terminator is missing; if open or near 0 Ohms, inspect the RJ45 cabling for short circuits or open pairs. Additionally, verify via the Smartpack configuration software that no node ID collision exists with adjacent nodes.

### How are the 4 analog inputs configured for Battery Symmetry monitoring, and what are the strict common-mode voltage wiring restrictions?

In the Smartpack GUI, map the desired analog channel to 'Symmetry'. The differential input channels share a common ground reference with the node. While inputs tolerate site floating DC common-mode levels up to nominal rail potentials, the differential voltage across any symmetry input pair must remain within its specified full-scale input envelope (typically ±5V or ±10V deviation around midpoint). In systems exceeding 60V nominal (e.g., 110V/220V substations), direct wiring to high-potential midpoints will saturate or destroy the internal analog front-end; external voltage divider boxes must be inserted.

### What surge protection and wiring precautions are required when the 4 relay outputs drive inductive loads such as high-current DC contactor coils?

The onboard relays are rated for low-voltage signal levels (max 60VDC / 1A resistive). When driving inductive loads such as LVD contactor coils, generator solenoid actuators, or external interposing relays, an external flyback suppression diode (e.g., fast-recovery or 1N4007) MUST be installed antiparallel across the DC coil terminals, or an appropriately rated MOV/RC snubber for AC. Omitting this allows back-EMF inductive voltage spikes (often exceeding 400V) to arc across the relay contacts, resulting in contact welding, PCB track degradation, and localized CAN transceiver lock-up.

### Following hardware replacement of a 242100.120 module, the master controller fails to map its I/O assignments. What rediscovery and remapping sequence must be followed?

When a replacement node is inserted, the Smartpack supervisory controller retains the hardware Serial Number (UID) of the retired unit, blocking automatic inheritance. Follow this carrier recovery procedure: 1) Log in via web browser or connect via PowerSuite service software; 2) In the 'CAN Nodes' configuration tree, locate the orphaned I/O node (marked in comm error) and execute 'Delete / Unregister Node'; 3) Verify physical cabling and execute 'Scan CAN Bus / Detect Nodes'; 4) Once the new serial number appears, reassign the logical I/O points manually or restore the pre-maintenance site configuration XML file.