# Eltek 268035 Flatpack2 (4AC 4-Slot Subrack DC Power System)

RICEWIND · Eltek

https://ricewind.com/en/products/eltek-268035-fp2-4ac-hvdc

Model: Eltek 268035 FP2 4AC HVDC

The Eltek 268035 Flatpack2 4AC is a high-reliability 4-slot subrack power shelf featuring individual AC input feeds per rectifier bay, engineered for Flatpack2 high-efficiency telecom rectifiers.

## What this product is

19-inch rackmount 4-position power subrack supporting individual AC inputs per rectifier.

## What problem it solves

Guarantees ultimate AC feed redundancy and modular serviceability for core telecommunication exchange installations.

## Who and where it is for

Central office DC power plants, datacenter power distribution shelves, and high-reliability backup systems.

## Core advantages

- Individual 4-channel AC input architecture provides unmatched electrical isolation
- Full compatibility with Flatpack2 2kW and 3kW high-efficiency rectifiers
- Hot-swappable tool-free rectifier module replacement
- Robust heavy-gauge chassis with superior EMC shielding

## Applications

- Telecom 4G/5G macro cellular base stations and distributed remote power sites
- Enterprise-grade cloud data center mission-critical -48V DC power distribution lineups
- Utility power grid dispatch centers and high-voltage substation DC switchgear rooms
- Railway transit signaling, automated train control, and communications equipment rooms

## Technical specifications

- System Output Capacity: 200 A
- Nominal Output Voltage: -48VDC (-42V ~ -58V) VDC
- Output Voltage Range: -48VDC (-42V ~ -58V) VDC
- AC Input Voltage: 85 ~ 300 VAC / supports direct high-voltage DC HVDC input
- Rectifier Module Slots: 4-slot Flatpack2 subrack with independent AC inputs
- System Monitoring Controller: Smartpack2 / Smartpack S centralized control
- Power Conversion Efficiency:  96.5%
- Ingress Protection (IP Rating): IP20
- Physical Dimensions: 88 × 482 × 380 mm (2U 19-inch)
- Operating Temperature Range: -40°C to +75°C

## Frequently asked questions

### Is Eltek 268035 FP2 4AC HVDC compatible with existing batteries, generators, and rectifiers?

Compatibility depends on DC bus voltage, telemetry protocols, and mechanical form factors. Describe your existing site setup and RICEWIND engineers can verify integration feasibility before you order.

### How is Eltek 268035 FP2 4AC HVDC delivered? Does RICEWIND provide international shipping?

Power systems are packed in heavy-duty export-standard wooden crates for sea or air transport. RICEWIND ships worldwide — contact us to confirm inventory, freight options, and delivery schedules.

### What warranty and engineering support are available for Eltek 268035 FP2 4AC HVDC?

Warranty follows the manufacturer policy for the specific configuration. RICEWIND supports wiring schematics, remote commissioning guidance, spare parts, and engineer-level technical assistance.

### Does RICEWIND supply Eltek 268035 FP2 4AC HVDC?

Yes. RICEWIND supplies Eltek 268035 FP2 4AC HVDC with MOQ from 1 system; in-stock units dispatch within 24-48 hours with global logistics coverage.

### Is there a cross-reference or equivalent replacement for Eltek 268035 FP2 4AC HVDC?

RICEWIND maintains a cross-reference matrix covering Huawei, Vertiv, Eltek, and ZTE telecom power systems. Contact us for direct equivalents and expansion options for Eltek 268035 FP2 4AC HVDC.

### How do I plan and configure Eltek 268035 FP2 4AC HVDC for my telecom site?

Consider total DC load, N+1 redundancy, battery autonomy backup time, surge protection, and cabinet footprint. Share your project requirements with RICEWIND and we will propose a matched configuration.

### What are the electrical input characteristics, DC output capabilities, and conversion efficiency metrics of the Eltek 268035 Flatpack2 4AC subrack?

The Eltek 268035 (ELTEK-SYS-FP2-4AC-HVDC) features a standard 19-inch subrack architecture engineered for a maximum system capacity of 200 A at a nominal -48 VDC output (adjustable from -43 to -57.6 VDC). It provides 4 dedicated, physically isolated AC input terminals supporting 85 to 300 VAC single-phase input or direct 180 to 300 VDC HVDC feeds per slot. When populated with 4 Flatpack2 HE (High Efficiency) rectifier modules, the system achieves a peak efficiency \> 96.5%, a power factor (PF) ≥ 0.99, and THD \< 5%, substantially decreasing thermal dissipation and operational power expenses (OPEX).

### What engineering provisions does this 4-slot shelf offer regarding Flatpack2 module compatibility, CAN bus digital monitoring, and hot-swap expansion?

The subrack natively accommodates the entire Flatpack2 48V rectifier family (including 2000W standard, 3000W HE, and specialized HVDC industrial modules), supporting seamless blind-mate hot-swapping. Its backplane integrates an industrial CAN bus network engineered for plug-and-play communication with Smartpack2 or Smartpack S controllers. The system employs autonomous active digital load sharing with current imbalance \< 5% across all 4 slots, facilitating N+1 or N+2 redundancy. Removal or failure of a module triggers microsecond-level load redistribution without introducing DC bus voltage transients.

### How does the Eltek 268035 handle harsh telecom and outdoor cabinet environments in terms of thermal limits, surge tolerance, and Low Voltage Disconnect (LVD)?

Rated at IP20, the shelf operates reliably across an extended temperature range from -40°C to +75°C (adapting to module-level derating curves at elevated temperatures). It features front-to-back forced cooling pathways and heavy-duty tinned copper busbars to control resistance and thermal rise under continuous 200A loads. The architecture supports external contactor drivers for dual-stage Low Voltage Disconnect (BLVD for battery deep-discharge protection and LLVD for non-critical load shedding). Certified to IEC 60950-1 and EN 300 386 EMC standards, it effectively withstands Class C industrial surges.

Content updated: 2026-09-12T01:33:34.349Z