# East EA990 120kVA Modular High-Frequency Datacenter UPS (120kVA/120kW PF 1.0)

RICEWIND · East

https://ricewind.com/en/products/east-ea990-120kva

Model: East EA990 120kVA

High-reliability online double-conversion high-frequency Uninterruptible Power Supply (UPS) delivering zero-millisecond pure sine wave power to critical IT loads.

## What this product is

High-reliability online double-conversion high-frequency Uninterruptible Power Supply (UPS) delivering zero-millisecond pure sine wave power to critical IT loads.

## What problem it solves

Mitigates power outage risks, suppresses severe grid voltage fluctuations and transient harmonics, and ensures zero interruption to downstream operations.

## Who and where it is for

Mission-critical communications infrastructure, industrial automated manufacturing cells, edge computing nodes, and distributed enterprise data centers.

## Core advantages

- True online double-conversion topology providing 0ms transfer time to isolate mains surges, sags, and harmonic distortions
- High output power factor (PF up to 0.9-1.0) delivering maximum active power capacity for high-density IT server loads
- Dual DSP digital processor control achieving over 95% operating efficiency and up to 99% in ECO mode
- Intelligent battery management featuring automated boost/float switching and scheduled self-test routines

## Applications

- Enterprise and cloud data center core networking suites, server clusters, and SAN storage arrays
- Financial banking transactions, securities clearing systems, and trading floor mission-critical IT
- Healthcare medical imaging suites (MRI, CT scanners) and critical intensive care instrumentation
- Industrial automation production lines, robotic workcells, and supervisory PLC control systems

## Technical specifications

- Output Voltage & Regulation Accuracy: -48VDC (-42V ~ -58V)
- Cooling Topology & Airflow Management: Cooling Topology & Airflow Management
- Operating Temperature Range: Operating Temperature Range °C
- Input Voltage Operating Range: 138VAC ~ 485VAC (3-Phase 5-Wire System) VAC
- Rated System Capacity / Power: 120kVA / 120kW (PF 1.0)
- Management & Communication Interface: Management & Communication Interface
- Form Factor & Dimensions (HxWxD): 1400 × 600 × 850 mm
- Transfer Time & Dynamic Response: 0 ms
- Battery Storage Architecture: ±240VDC (30 to 46 Blocks Adjustable)

## Frequently asked questions

### How do I choose the right East EA990 120kVA for my system?

Verify host model, electrical ratings, interface types and protocol requirements. Share your system details with RICEWIND and we will compare compatible options across brands.

### Is East EA990 120kVA compatible with my existing equipment?

Compatibility depends on power input, pinout signals and rack mounting specifications. Our engineers can review interfaces and integration details before you order.

### Does RICEWIND provide international shipping for East EA990 120kVA?

Yes. RICEWIND ships worldwide; freight options depend on destination, weight and urgency. Contact us for a shipping quote to your site.

### What warranty and after-sales support are available for East EA990 120kVA?

Warranty follows the manufacturer policy for your region. RICEWIND provides technical documentation, firmware guidance and engineer-level assistance throughout the project.

### Does RICEWIND supply East EA990 120kVA?

Yes. RICEWIND supplies East EA990 120kVA with MOQ from 1 unit; in-stock items dispatch within 24-48 hours with worldwide shipping.

### Is there a cross-reference or equivalent for East EA990 120kVA?

RICEWIND maintains a cross-reference database covering leading telecom and energy infrastructure brands. Contact us for the direct equivalent of East EA990 120kVA.

### How to resolve airflow obstruction alarm on East EA990 120kVA in dusty environments?

Remove front dust filters, clean with dry compressed air, verify tachometer wiring connectors on fans, and clear heatsink channel debris to clear the fault.

### What are the diagnostic steps when East EA990 120kVA triggers DC bus overvoltage protection?

Disconnect AC input, measure static open-circuit battery voltage, check for unbalanced cells causing elevated float voltage, and verify boost charge voltage parameters.

### What are the primary causes for communication packet loss or offline alarms on East EA990 120kVA?

Commonly caused by ungrounded RS485 cable shielding, missing 120-ohm bus termination resistors, or baud rate/address conflicts on the multidrop loop.

### How to execute a comprehensive hardware and firmware reset on East EA990 120kVA following EMI events?

Isolate AC and battery breakers, hold the reset/mute button for 15 seconds to discharge residual capacitance, and recalibrate system status registers via service mode.

Content updated: 2026-09-15T14:00:00.663Z