# DPC DUMC-4850H Compact Subrack Telecom DC Power System (-48V 50A 1U)

RICEWIND · Dpc

https://ricewind.com/en/products/dumc-4850h

Model: DUMC-4850H

The DUMC-4850H is a 1U compact -48V 50A embedded high-frequency switched-mode DC power system engineered for telecom access networks, wireless cellular sites, and industrial edge computing nodes.

## What this product is

The DPC DUMC-4850H is a standardized 19-inch rack-mounted DC power architecture integrating high-efficiency switch-mode rectifiers, a digital Central Supervisory Unit (CSU), and an integrated AC/DC distribution block. It converts raw utility or generator AC power into clean, regulated -48V DC to power sensitive telecom active loads while maintaining float charging on back-up batteries with zero-millisecond transition during grid dropouts.

## What problem it solves

Mitigates severe physical footprint constraints inside outdoor telecom enclosures, protects critical communications electronics against severe grid fluctuations (85VAC to 300VAC), and prevents catastrophic battery degradation through precision multi-stage charging and dual LVD controls.

## Who and where it is for

4G/5G small cell base stations, RRU distributed power feeds, broadband enterprise access nodes, rail signaling shelters, roadside ITS cabinets, and ruggedized edge computing hubs.

## Core advantages

- Ultra-wide AC input from 85VAC to 300VAC handles unstable grids, eliminating downtime in remote base stations.
- High-density 19-inch 1U embedded architecture with a 50A rectifier perfectly fits space-constrained edge cabinets.
- Advanced DK04 microcontroller provides intelligent battery management and temperature compensation to maximize lifespan.
- Peak conversion efficiency exceeding 95.5% significantly lowers operating energy costs and thermal dissipation.

## Applications

- Telecom 4G/5G macro cellular base stations and distributed remote power sites
- Enterprise-grade cloud data center mission-critical -48V DC power distribution lineups
- Utility power grid dispatch centers and high-voltage substation DC switchgear rooms
- Railway transit signaling, automated train control, and communications equipment rooms

## Technical specifications

- Cooling System Architecture: Low-noise temperature-controlled cooling
- AC Input Voltage: 85VAC ~ 300VAC (Nominal 220VAC) VAC
- Smart Monitoring Controller: DK04 Embedded Controller Unit
- Nominal Output Voltage: -48VDC (-42V ~ -58V) VDC
- Rated DC Output Current: 50A (System Capacity 2.9kW)
- Managed Rectifier Capacity: 1 × 50A
- Peak Energy Efficiency: ≥95.5%
- Form Factor Dimensions (HxWxD): 44 (1U) × 482 × 290 mm
- Operating Temperature Range: -30°C ~ +60°C

## Frequently asked questions

### How do I choose the right DUMC-4850H for my system?

Verify host model, electrical ratings, interface types and protocol requirements. Share your system details with RICEWIND and we will compare compatible options across brands.

### Is DUMC-4850H compatible with my existing equipment?

Compatibility depends on power input, pinout signals and rack mounting specifications. Our engineers can review interfaces and integration details before you order.

### Does RICEWIND provide international shipping for DUMC-4850H?

Yes. RICEWIND ships worldwide; freight options depend on destination, weight and urgency. Contact us for a shipping quote to your site.

### What warranty and after-sales support are available for DUMC-4850H?

Warranty follows the manufacturer policy for your region. RICEWIND provides technical documentation, firmware guidance and engineer-level assistance throughout the project.

### Does RICEWIND supply DUMC-4850H?

Yes. RICEWIND supplies DUMC-4850H with MOQ from 1 unit; in-stock items dispatch within 24-48 hours with worldwide shipping.

### Is there a cross-reference or equivalent for DUMC-4850H?

RICEWIND maintains a cross-reference database covering leading telecom and energy infrastructure brands. Contact us for the direct equivalent of DUMC-4850H.

### How do you calculate the DC feeder cable cross-section and loop voltage drop for the DUMC-4850H to a -48V distribution block?

The DC loop voltage drop is calculated via: ΔU = (2 × L × I) / (γ × S), where L is the one-way cable run (meters), I is maximum circuit load (50A full capacity), γ is copper conductivity (57 m/(Ω·mm²)), and S is cross-sectional area (mm²). Telecom engineering standards dictate total feeder drop between rectifier terminals and active distribution should not exceed 0.5V. For a 10m one-way run at 50A: S = (2 × 10 × 50) / (57 × 0.5) ≈ 35.08 mm². Therefore, a standardized multi-strand copper cable of at least 35 mm² (or 2 AWG) rated for 90°C must be deployed.

### What are the recommended threshold voltage settings for LLVD and BLVD in the DUMC-4850H system?

For a standard 48V VRLA lead-acid bank (24 cells @ 2V), standard practice is: LLVD (non-critical load drop) is set to -44.0VDC to -44.5VDC (approx. 1.83~1.85V/cell) to shed non-essential loads, extending runtime for critical transmission. BLVD (battery protect disconnect) is programmed to -43.2VDC (1.80V/cell) to completely isolate the battery strings before permanent cell polarity reversal or severe sulfation occurs. For 15S/16S LiFePO4 batteries, set BLVD to -43.5VDC or match the BMS low-voltage alarm limit. Reconnection thresholds should be configured at -48.0VDC or higher once mains returns.

### How should the battery temperature compensation coefficient be configured, and where should the thermal sensor probe be attached?

For VRLA batteries, benchmark reference temperature is 25°C, and the compensation slope should be set to -3.0 to -3.5 mV/(°C·cell), equating to -72 to -84 mV/°C for a 48V system (24 cells). As ambient temp rises, the CSU reduces float voltage to avert thermal runaway; as temp falls, it increases voltage to guarantee full capacity recharge. The physical NTC sensor probe must never hang loosely in cabinet air; it must be firmly attached using thermal mastic or mechanical ties to the negative terminal post or side wall of the central, thermally restricted battery block.

### What is the troubleshooting and calibration procedure for parallel rectifier current sharing imbalance on the DUMC-4850H?

Telecom rectifiers operating between 50% and 100% rated capacity must maintain active current share imbalance within ±5% of rated current. If imbalance occurs: 1) Verify continuity and termination resistance of the internal CAN/RS485 bus; lost packet communications force modules into autonomous fallback mode. 2) Access the CSU calibration menu to verify that individual output voltage sets do not deviate by more than 20mV. 3) Inspect DC output busbar lug torques with a calibrated torque wrench—loose terminations increase contact resistance and distort active load sharing. 4) If a single rectifier sits idle at 0A or locks at max current, execute a hot-reseat; if uncorrected, replace the faulty rectifier control subassembly.