# DPC DZY4850B Industrial High-Capacity Switch-Mode Telecom Rectifier (-48V 50A 2900W)

RICEWIND · Dpc

https://ricewind.com/en/products/dpc-dzy4850b-b30

Model: DZY4850B

The DPC DZY4850B is an industrial-grade, high-capacity switch-mode telecom rectifier module engineered for -48V DC telecom power architectures (adjustable from -43V to -58V DC), delivering up to 50A output current with a continuous rated power of 2900W. Designed for carrier-grade central offices and cellular base stations, it provides robust power conversion under harsh grid conditions.

## What this product is

The DZY4850B is a high-frequency power conversion sub-assembly comprising wideband two-stage EMI filtering, an active boost PFC stage, a phase-shifted full-bridge ZVS DC-DC converter, and secondary synchronous rectification. Supervised by an on-board industrial microcontroller, it continuously monitors phase voltage, thermal metrics, and load sharing, communicating diagnostics in real-time to the system power controller in compliance with IEC/EN 60950 and EN 55022 Class B standards.

## What problem it solves

It eliminates equipment shutdowns caused by wide grid sags and voltage surges across unstable AC lines through its wide 90V to 290V AC input window. Furthermore, integrated hardware-based selective overvoltage shutdown (OVP) and autonomous active current sharing prevent catastrophic DC bus overvoltage and module load-dump cascading during parallel plant operations.

## Who and where it is for

Ideal for 4G/5G macro cell towers, telecom carrier switching centers, microwave backhaul stations, railway signaling and communication cabinets, and utility substation -48V DC auxiliary power systems.

## Core advantages

- Wide 90V-290V AC input range and two-stage PFC ensure robust grid adaptability in harsh environments.
- 2900W high power density with up to 93.0% peak efficiency delivers carrier-grade energy savings.
- Independent hardware OVP and high-precision active current sharing secure the -48V DC bus stability.
- Live hot-pluggable design and intelligent variable-speed cooling fulfill high-reliability telecom maintenance.

## Applications

- 4G/5G base transceiver station (BTS) outdoor power enclosures and shelter plants
- Central office carrier-grade -48V DC power distribution and modular rectifier bays
- High-speed railway telecommunication networks and trackside signal power skids
- Electric utility transmission substation SCADA and optical communication -48V DC banks

## Technical specifications

- Rated Output Voltage: -48VDC (-42V ~ -58V)
- Maximum Output Current: 50A
- Rated Output Power: 2900W
- AC Input Voltage: 90V AC ~ 290V AC
- Maximum Efficiency: ≥ 93.0%
- Operating Temperature Range: -40°C ~ +75°C
- Cooling System: Forced Air Cooling with Intelligent Speed Fan
- Hot-Swappable Support: Yes (Live Hot-Pluggable / Plug-and-Play without Power Interruption)

## Frequently asked questions

### How do I select DZY4850B for my power system?

Check output voltage, module power rating, efficiency class and compatibility with your existing rectifier shelf or controller. RICEWIND can verify fitment and propose the right quantity.

### Is DZY4850B compatible with my existing system?

Compatibility depends on the rectifier shelf, controller and communication protocol. Send your current system model to RICEWIND and our engineers will confirm which modules fit.

### Does RICEWIND provide international shipping for DZY4850B?

Yes. Power modules and systems are packed in anti-static, export-standard crates and shipped worldwide. Delivery time and freight options depend on stock and destination — contact RICEWIND for quotes and lead times.

### What warranty and technical support apply to DZY4850B?

Warranty follows the manufacturer's policy for the specific equipment. RICEWIND supports testing guidance, replacement requests, spare parts and technical coordination per order terms.

### Does RICEWIND supply DZY4850B from stock?

Yes. RICEWIND supplies DZY4850B from verified stock with MOQ from 1 piece; in-stock units dispatch within 24-48 hours with global express air and sea freight.

### Is there a cross-reference or equivalent for DZY4850B?

RICEWIND maintains a comprehensive cross-reference chart covering Huawei, Vertiv (Emerson), Eltek, ZTE and Delta 48V telecom rectifiers. Contact us for the direct equivalent of DZY4850B.

### What is the primary cause if the DZY4850B illuminates a steady yellow alarm LED while still delivering DC output?

A steady yellow LED indicates a non-critical warning state. Typical field causes include an input AC sag below 176V AC forcing the unit into thermal/power derating mode, high ambient ambient temperatures triggering over-temperature protection, or partially blocked air filters restricting fan intake flow. Verify line voltage and clean intake dust screens.

### Can the DZY4850B provide its full 50A / 2900W rated output when powered by a 110V AC nominal source?

No. The DZY4850B delivers its full 2900W (50A) capacity within the 176V to 290V AC input window. Below 176V AC down to 90V AC, an integrated microcontroller implements linear thermal and current derating, yielding approximately 50% power output at 90V AC to protect the input PFC stage from thermal overstress.

### Is it safe to hot-swap a DZY4850B module without disconnecting the AC or DC circuit breakers?

Yes. The DZY4850B features a staged blind-mate edge connector with staggered pin lengths that engage chassis ground first, followed by soft-start pre-charge logic and power pins. This suppresses inrush current and eliminates electrical arcing, allowing safe extraction and insertion under full live operating conditions.

### What maintenance step is required if one module in an N+1 rack fails to share load equally with parallel units?

First inspect the rear gold-plated blind-mate connectors for mechanical damage or contamination on the active current-share pins. Next, confirm via the central monitoring unit that the module float voltage setpoint matches the system target. If settings and connections are verified, a failure within the internal current sensing shunt or buffer op-amp necessitates module replacement.

Content updated: 2026-09-17T01:31:49.465Z