# DPC DZY24100B High-Current High-Frequency 24V DC Rectifier Module (24V 100A 2400W)

RICEWIND · Dpc

https://ricewind.com/en/products/dpc-dzy24100b-b30

Model: DZY24100B

The DPC DZY24100B is an industrial-grade high-frequency switch-mode telecom rectifier module engineered for carrier-grade DC power plants, delivering a nominal 24V DC output, up to 100A continuous current, and a 2400W rated capacity.

## What this product is

The DZY24100B incorporates multi-stage EMI suppression, a robust boost APFC pre-regulator, and an isolated DC-DC resonant converter topology. Governed by high-precision closed-loop control circuitry, it enforces tight voltage regulation, active autonomous load sharing, and comprehensive hardware protections against AC over/undervoltage, output OVP, overtemperature, and continuous short circuits in compliance with major telecom standards.

## What problem it solves

Eliminates network downtime caused by severe utility voltage fluctuations in remote base stations, mitigates 24V DC bus voltage sags under sudden dynamic load steps, resolves unequal module current distribution in multi-shelf arrays, and prevents thermal runaway in high-density telecom cabinets.

## Who and where it is for

Tailored for 24V telecom BTS installations, optical transmission hubs, microwave repeaters, SCADA and RTU automation enclosures, industrial 24V DC bus systems, and mobile emergency communications trailers.

## Core advantages

- Wide AC input range (90V-290V) withstands severe grid fluctuations in remote base stations
- Two-phase interleaved APFC topology delivers high conversion efficiency ≥ 92.0%
- Advanced DSP digital control and master-free active current sharing support hot-swappable parallel operation
- -25°C to +65°C operating temperature with intelligent fan cooling prevents thermal breakdown in harsh cabinets

## Applications

- Main rectifier bays for legacy and modern 24V wireless base transceiver stations (BTS)
- Continuous DC power supplies for industrial DCS, PLC, and supervisory control hardware
- Utility substation automation terminals and telemetry remote terminal units (RTUs)
- Fixed and containerized optical transport nodes, microwave links, and mobile telecom vans

## Technical specifications

- AC Input Voltage: 90V AC ~ 290V AC
- Rated Output Power: 2400W
- Maximum Output Current: 100A
- Rated Output Voltage: -48VDC (-42V ~ -58V)
- Maximum Efficiency: ≥ 92.0%
- Operating Temperature Range: -40°C ~ +75°C
- Cooling System: Forced Air Cooling with Intelligent Speed Fan
- Hot-Swappable Support: Yes (Live Hot-Pluggable / Plug-and-Play without Power Interruption)

## Frequently asked questions

### How do I select DZY24100B for my power system?

Check output voltage, module power rating, efficiency class and compatibility with your existing rectifier shelf or controller. RICEWIND can verify fitment and propose the right quantity.

### Is DZY24100B compatible with my existing system?

Compatibility depends on the rectifier shelf, controller and communication protocol. Send your current system model to RICEWIND and our engineers will confirm which modules fit.

### Does RICEWIND provide international shipping for DZY24100B?

Yes. Power modules and systems are packed in anti-static, export-standard crates and shipped worldwide. Delivery time and freight options depend on stock and destination — contact RICEWIND for quotes and lead times.

### What warranty and technical support apply to DZY24100B?

Warranty follows the manufacturer's policy for the specific equipment. RICEWIND supports testing guidance, replacement requests, spare parts and technical coordination per order terms.

### Does RICEWIND supply DZY24100B from stock?

Yes. RICEWIND supplies DZY24100B from verified stock with MOQ from 1 piece; in-stock units dispatch within 24-48 hours with global express air and sea freight.

### Is there a cross-reference or equivalent for DZY24100B?

RICEWIND maintains a comprehensive cross-reference chart covering Huawei, Vertiv (Emerson), Eltek, ZTE and Delta 48V telecom rectifiers. Contact us for the direct equivalent of DZY24100B.

### How does the DZY24100B manage power output when the AC mains input falls below 176V AC?

The module utilizes an automatic input current limiting and linear derating profile. Between 176V AC and 290V AC, it delivers full 2400W (24V/100A) capacity. When the input drops below 176V AC down to 90V AC, the internal controller limits primary-side bridge current, derating output capacity to roughly 50% to 80% to protect the active PFC MOSFETs from thermal and current saturation.

### How is active load sharing established when multiple DZY24100B modules are paralleled in a single rack?

Load sharing is handled through a dedicated analog share-bus line integrated into the backplane connector. Each rectifier dynamically compares its actual delivered current against the average system signal on the bus, trimming its internal PWM drive loop to keep current imbalance among all parallel modules within ±5% without requiring intervention from a central supervisory unit.

### What causes an Output Over-Voltage Protection (OVP) latch-off, and how is it restored in the field?

Output OVP activates when the terminal voltage exceeds the safety threshold (typically 30V~31V DC) to safeguard downstream equipment. This triggers a hardware latch that shuts down PWM switching. To restore operation, isolate the module from the AC input and backplane, verify external bus voltages and inter-module isolation, wait 3 minutes for internal bulk capacitors to bleed off, and reseat the unit.

### What are the common causes of a continuous high-speed fan alarm on the DZY24100B module?

A fan alarm or constant full-speed state typically occurs when internal thermistors detect intake air exceeding 45°C or internal heatsink hotspots, often caused by dust-choked front air filters or clogged exhaust tunnels. It can also stem from a broken tachometer feedback signal or bearing wear. Technicians should inspect and vacuum air paths or replace the fan cartridge if the alarm persists.

Content updated: 2026-09-17T01:31:36.931Z