# DPC DZY-48/50HI Telecom Rectifier Module (48V 50A 2900W Switch Power Supply)

RICEWIND · Dpc

https://ricewind.com/en/products/dpc-dzy-4850hi-module

Model: DPC DZY-48/50HI Telecom Rectifier Module

The DPC DZY-48/50HI is an industrial-grade high-frequency telecom rectifier module utilizing fully digitalized soft-switching topology to convert a 90V-290V single-phase AC input into a stable nominal -48V DC output, delivering 50A continuous current and 2900W rated power for telecom cabinets and DC power plants.

## What this product is

The DPC DZY-48/50HI is an industrial-grade high-frequency telecom rectifier module utilizing fully digitalized soft-switching topology to convert a 90V-290V single-phase AC input into a stable nominal -48V DC output, delivering 50A continuous current and 2900W rated power for telecom cabinets and DC power plants.

## What problem it solves

The DPC DZY-48/50HI rectifier module is engineered by Beijing Dynamic Power for mission-critical telecom sites and enterprise DC power distribution. Built on active power factor correction (APFC) and high-density soft-switching circuits, it achieves peak electrical efficiency exceeding 95.2% to reduce operational cooling footprints. It features seamless hot-plug insertion with active autonomous current sharing (\<3% unbalance), combined with industrial protections including input surge suppression, output hardware overvoltage latching, thermal foldback, and short-circuit protection. Dual ball-bearing temperature-regulated fans ensure uninterrupted 24/7 reliability across a wide temperature window of -25°C to +70°C.

## Who and where it is for

The DPC DZY-48/50HI is an industrial-grade high-frequency telecom rectifier module utilizing fully digitalized soft-switching topology to convert a 90V-290V single-phase AC input into a stable nominal -48V DC output, delivering 50A continuous current and 2900W rated power for telecom cabinets and DC power plants.

## Core advantages

- Fully digital soft-switching architecture achieving efficiency ≥95.2%
- Wide single-phase AC input from 90V to 290V withstands severe grid surges
- Drawer-type hot-pluggable design with autonomous current sharing unbalance \<3%
- Internal stepless variable-speed ball-bearing fan optimizes forced cooling
- Integrated protections for input surge, output overvoltage latch, and shorts
- Industrial ruggedness operational across -25°C to +70°C ambient temperatures

## Applications

- 4G/5G macro and micro base station -48V DC power infrastructure
- Telecom operator central offices and edge computing data racks
- Railway signaling, train dispatching, and trackside DC power supply
- Substation communications automation and utility backup power racks
- Industrial SCADA, DCS, and automated manufacturing direct current buses
- Offshore oil platforms and isolated microgrid hybrid communication sites

## Technical specifications

- Rated output voltage: -48VDC (-42V ~ -58V)
- Rated output power: 2900W Nominal Telecom Rectifier Output Power
- DC output current: 50A Continuous Constant Current Output Capability
- AC input voltage range: 90V AC ~ 290V AC Single-Phase Wide Grid Tolerance
- Hot-swap capability: Slide-in Hot-Swap with Digital Active Load Sharing (\<3%)
- Efficiency (measured): ≥ 95.2%
- Operating Temperature Range: -25°C ~ +70°C
- Cooling method: Internal Temperature-Controlled Stepless Variable-Speed Ball-Bearing Fan

## Frequently asked questions

### How do I choose the right DPC DZY-48/50HI Telecom Rectifier Module for my system?

Verify host model, electrical ratings, interface types and protocol requirements. Share your system details with RICEWIND and we will compare compatible options across brands.

### Is DPC DZY-48/50HI Telecom Rectifier Module compatible with my existing equipment?

Compatibility depends on power input, pinout signals and rack mounting specifications. Our engineers can review interfaces and integration details before you order.

### Does RICEWIND provide international shipping for DPC DZY-48/50HI Telecom Rectifier Module?

Yes. RICEWIND ships worldwide; freight options depend on destination, weight and urgency. Contact us for a shipping quote to your site.

### What warranty and after-sales support are available for DPC DZY-48/50HI Telecom Rectifier Module?

Warranty follows the manufacturer policy for your region. RICEWIND provides technical documentation, firmware guidance and engineer-level assistance throughout the project.

### Does RICEWIND supply DPC DZY-48/50HI Telecom Rectifier Module?

Yes. RICEWIND supplies DPC DZY-48/50HI Telecom Rectifier Module with MOQ from 1 unit; in-stock items dispatch within 24-48 hours with worldwide shipping.

### Is there a cross-reference or equivalent for DPC DZY-48/50HI Telecom Rectifier Module?

RICEWIND maintains a cross-reference database covering leading telecom and energy infrastructure brands. Contact us for the direct equivalent of DPC DZY-48/50HI Telecom Rectifier Module.

### What are the rated output power, constant current limits, and efficiency ratings of DPC DZY-48/50HI?

The module delivers 2900W nominal output power at -48V DC (adjustable from -43V to -58V DC) with a 50A continuous constant current rating. Featuring fully digital soft-switching APFC topology, it achieves a power factor of ≥0.99, an electrical conversion efficiency exceeding 95.2% between 50% and 100% load, and THD under 5%.

### How are the chassis integration, form factor, hot-swap mechanism, and ventilation paths designed?

The DPC DZY-48/50HI features a compact sub-rack drawer form factor compatible with high-density telecom enclosures. It uses backplane blind-mate gold-plated power connectors for hot-swapping without bus voltage dips. Forced cooling operates front-to-rear via internal stepless variable-speed ball-bearing fans regulated by internal thermal sensors.

### What hardware protections counteract electrical surges, power grid fluctuations, and extreme temperatures?

The module operates from 90V to 290V AC with dynamic derating during severe fluctuations. It embeds a dual-stage metal oxide varistor (MOV) surge network supporting 2kV differential and 4kV common mode protection. Additional circuits deliver hardware output overvoltage latching, short-circuit hiccup recovery, and automatic thermal derating up to +70°C.

### How are autonomous current sharing and battery management redundancy implemented in parallel clusters?

The module features an integrated autonomous current-sharing circuit maintaining load unbalance under 3% across parallel units without centralized master controllers. Under supervisory control, it executes precise constant-current recharge, temperature-compensated float charge, battery equalization, and dual-stage low voltage disconnect (LVD) triggers.

### Which communications buses and upper-layer remote monitoring protocols are supported by DPC DZY-48/50HI?

The unit exposes CAN bus and isolated RS485 physical interfaces across its rear backplane connectors. When paired with a host controller unit, internal parameters bridge to standard Modbus-RTU, SNMP v2c/v3, and Web interfaces, providing real-time telemetry polling, alarm monitoring, and remote voltage calibration.

### What full-load burn-in inspections and international packaging standards does execute before dispatch?

subjects every exported unit to a 4-hour 100% full-load (50A/2900W) burn-in run under thermal stress, attaching an individual QC test sheet covering dielectric insulation, current-share deviation, and output ripple. Products are sealed in ESD-safe shielding, fitted into molded high-density EPE foam, and crated in export-grade fumigation-free wooden cases.

Content updated: 2026-09-14T03:40:18.599Z