# DPC DYS 50H3 2.1m Outdoor Telecom Power Cabinet System (48V 300A-600A IP55)

RICEWIND · Dpc

https://ricewind.com/en/products/dpc-dys-50h3-outdoor

Model: DPC DYS 50H3 2.1m Outdoor Power Cabinet

The DPC DYS 50H3 is a 2.1-meter industrial-grade outdoor integrated telecom power cabinet system combining high-efficiency switch-mode rectifiers, AC/DC power distribution, dynamic environmental monitoring, and heavy-duty battery compartments. Delivering -48V DC output with scalable capacity from 300A to 600A and IP55 sealed enclosure protection, it guarantees continuous mission-critical power for global macro cell sites and transport networks in harsh terrains.

## What this product is

The DPC DYS 50H3 is a 2.1-meter industrial-grade outdoor integrated telecom power cabinet system combining high-efficiency switch-mode rectifiers, AC/DC power distribution, dynamic environmental monitoring, and heavy-duty battery compartments. Delivering -48V DC output with scalable capacity from 300A to 600A and IP55 sealed enclosure protection, it guarantees continuous mission-critical power for global macro cell sites and transport networks in harsh terrains.

## What problem it solves

The DPC DYS 50H3 2.1m Outdoor Power Cabinet is engineered as an ultra-reliable, all-weather power infrastructure for severe outdoor operating conditions. Fabricated from premium double-wall galvanized steel with integrated polyurethane thermal insulation and IP55-rated gaskets, the cabinet resists heavy rain, sandstorms, and corrosive coastal salt fog. Thermal dissipation relies on dual door-mounted high-efficiency heat exchangers, establishing isolated closed-loop air paths that eliminate ambient dust ingress while keeping rectifiers and electronics at optimal operating temperatures. Powered by a parallel array of DYS-4850H 50A high-frequency rectifiers, the system supports N+1 modular redundancy and live hot-plug maintenance. The power core features heavy-duty copper busbars, multi-tier AC/DC breaker branches, and multi-string battery shelving, unified under a digital supervision unit compatible with SNMP and Modbus protocols.

## Who and where it is for

The DPC DYS 50H3 is a 2.1-meter industrial-grade outdoor integrated telecom power cabinet system combining high-efficiency switch-mode rectifiers, AC/DC power distribution, dynamic environmental monitoring, and heavy-duty battery compartments. Delivering -48V DC output with scalable capacity from 300A to 600A and IP55 sealed enclosure protection, it guarantees continuous mission-critical power for global macro cell sites and transport networks in harsh terrains.

## Core advantages

- Equipped with 50A high-frequency rectifiers reaching over 96% peak efficiency to cut site thermal dissipation.
- Double-walled galvanized steel enclosure with IP55 protection prevents dust, rain, and solar thermal loading.
- Dual closed-loop heat exchangers isolate internal electronics from corrosive moisture, salt fog, and grit.
- Modular hot-swappable rectifiers and controller allow real-time field expansion without service interruption.
- Two-stage LLVD and BLVD disconnects protect energy storage batteries from catastrophic deep discharge.
- Full digital supervisory unit supports SNMP, Modbus, and dry contacts for centralized remote OSS integration.

## Applications

- 4G/5G macro cell outdoor standalone power infrastructure
- Railway signaling and highway corridor telecom relay stations
- Coastal and offshore island transmission networks with heavy salt fog
- Desert and high-temperature arid edge computing nodes
- Sub-zero extreme cold and high-altitude remote telecom links
- Oil & gas pipeline SCADA and utility electrical substation hubs

## Technical specifications

- System Output Capacity: 300A ~ 600A Flexible Expandable Total DC Capacity
- Cabinet Structure Spec: 2.1m Heavy-Duty Double-Wall Insulated Outdoor Cabinet (IP55 Sealed)
- Compatible Rectifiers: DYS-4850H 50A High-Frequency Switchmode Rectifiers
- Heat Exchange Tech: Dual High-Efficiency Heat Exchangers + Self-Cleaning Dust Filter Ducts
- Environment Monitoring Unit: Large Digital Supervisory Controller (SNMP & Modbus Compatible)
- AC/DC Distribution Unit: Heavy-Duty Copper Busbars + Multi-Channel Output Branch Breakers
- Battery Cabin Structure: Built-in Heavy-Duty Reinforced Battery Racks Supporting Multiple Strings
- Operating Temperature Range: -40°C ~ +50°C

## Frequently asked questions

### Is DPC DYS 50H3 2.1m Outdoor Power Cabinet compatible with existing batteries, generators, and rectifiers?

Compatibility depends on DC bus voltage, telemetry protocols, and mechanical form factors. Describe your existing site setup and RICEWIND engineers can verify integration feasibility before you order.

### How is DPC DYS 50H3 2.1m Outdoor Power Cabinet delivered? Does RICEWIND provide international shipping?

Power systems are packed in heavy-duty export-standard wooden crates for sea or air transport. RICEWIND ships worldwide — contact us to confirm inventory, freight options, and delivery schedules.

### What warranty and engineering support are available for DPC DYS 50H3 2.1m Outdoor Power Cabinet?

Warranty follows the manufacturer policy for the specific configuration. RICEWIND supports wiring schematics, remote commissioning guidance, spare parts, and engineer-level technical assistance.

### Does RICEWIND supply DPC DYS 50H3 2.1m Outdoor Power Cabinet?

Yes. RICEWIND supplies DPC DYS 50H3 2.1m Outdoor Power Cabinet with MOQ from 1 system; in-stock units dispatch within 24-48 hours with global logistics coverage.

### Is there a cross-reference or equivalent replacement for DPC DYS 50H3 2.1m Outdoor Power Cabinet?

RICEWIND maintains a cross-reference matrix covering Huawei, Vertiv, Eltek, and ZTE telecom power systems. Contact us for direct equivalents and expansion options for DPC DYS 50H3 2.1m Outdoor Power Cabinet.

### How do I plan and configure DPC DYS 50H3 2.1m Outdoor Power Cabinet for my telecom site?

Consider total DC load, N+1 redundancy, battery autonomy backup time, surge protection, and cabinet footprint. Share your project requirements with RICEWIND and we will propose a matched configuration.

### What is the total output capacity of the DPC DYS 50H3 system, and how are rectifiers configured?

The system delivers a nominal -48V DC output with total current capacity scalable from 300A to 600A. It utilizes DYS-4850H (48V/50A) switch-mode rectifier modules accommodated in flexible 6 to 12-slot subracks for N+1 redundancy. Individual rectifiers boast peak efficiencies exceeding 96% and support live hot-swapping, enabling hitless capacity upgrades in the field without traffic disruption.

### What is the structural thermal insulation design and operating principle of the dual heat exchangers?

The cabinet is constructed with 2.1-meter double-wall galvanized steel lined with flame-retardant polyurethane insulation, sealed with continuous foamed gaskets to achieve IP55-rated protection. Cooling is managed by dual door-mounted heat exchangers featuring two completely isolated air circulation loops. This design transfers internal heat outside while preventing atmospheric dust, humidity, and corrosive salt fog from entering the sensitive equipment bay.

### How does the system withstand extreme environmental stresses such as wide temperatures, lightning, and salt spray?

Engineered for harsh environments, the system operates across a -40°C to +50°C range (down to -45°C with optional heater kits). The exterior features heavy-duty UV-stabilized polyester powder coating tested against severe salt spray. AC and DC distribution paths include multi-stage surge arresters (standard Class C 20kA/40kA on AC input), complemented by three-point anti-theft locking to resist typhoons, sandstorms, and coastal corrosion.

### What are the load-bearing specifications of the battery bay and the LLVD/BLVD protection logic?

The lower section houses reinforced structural battery shelves rated for over 250kg per tier, accommodating 2 to 4 strings of 100Ah-200Ah VRLA or LiFePO4 batteries. The controller features precision charge-discharge algorithms with temperature compensation and two-stage low voltage disconnects: LLVD sheds non-essential loads to sustain transmission, while BLVD disconnects the battery bank before destructive deep discharge occurs.

Content updated: 2026-09-13T09:16:09.199Z