# DPC 4850C Heavy-Duty Telecom Switching Power Rectifier Module (-48V 50A 2900W)

RICEWIND · Dpc

https://ricewind.com/en/products/dpc-4850c-b30

Model: 4850C

The DPC 4850C is a heavy-duty, telecom-grade high-frequency switching power rectifier module designed for continuous operation in mission-critical DC power plants. Operating from a wide single-phase AC input range of 90V AC to 290V AC, it delivers a stabilized nominal -48V DC output (field-adjustable from -43V to -58V DC) with a maximum continuous output current of 50A and a rated output power of 2900W.

## What this product is

Architecturally, the DPC 4850C employs a dual-stage power electronic conversion circuit. The input stage utilizes an active Boost PFC converter operating in continuous conduction mode to enforce near-unity power factor and suppress input harmonic distortion according to international grid standards. The isolated DC-DC stage uses a Phase-Shifted Full-Bridge (PSFB) zero-voltage switching (ZVS) topology that steps down and rectifies high-voltage internal DC into tightly regulated telecom -48V power with low EMI and ripple. The entire unit is supervised by an industrial microcontroller managing dynamic thermal throttling, autonomous current sharing, and safe hot-swap blind-mate backplane communications.

## What problem it solves

The 4850C directly solves field challenges related to erratic AC utility networks, lightning surges, and unscheduled maintenance downtime in remote telecommunication shelters. Its wide 90V–290V AC operational window prevents premature battery bank discharge during severe voltage dips. In addition, its precision thermal-controlled air channels and self-locking hardware overvoltage protection (OVP) guard against component thermal fatigue and catastrophic downstream telecom load damage caused by runaway rail voltages.

## Who and where it is for

Ideal for wireless cellular macro base stations (4G/5G BTS, BBU, RRU), central offices, broadband optical line terminals (OLT), enterprise telecom server racks, electric utility substation DC panels, and railway trackside signaling communication hubs requiring uninterrupted, battery-backed -48V DC power.

## Core advantages

- Advanced CCM Boost and full-bridge phase-shifted ZVS topology delivering ≥92.5% peak efficiency.
- Ultra-wide AC input range (90V-300V) combats severe grid fluctuations and lightning surges.
- Autonomous active current sharing and millisecond-level hardware OVP ensure safe hot-swapping.
- Intelligent fan speed control and optimized dust-proof cooling prevent thermal breakdown in high temps.

## Applications

- Cellular base station outdoor power enclosures and indoor power distribution racks
- Telecom exchange central offices and optical transport transmission network nodes
- Industrial electrical substation automation panels and SCADA backup DC systems
- Railway trackside signaling, radio dispatching, and emergency communication systems

## Technical specifications

- AC Input Voltage: 90V AC ~ 290V AC
- Rated Output Voltage: -48VDC (-42V ~ -58V)
- Maximum Output Current: 50A
- Rated Output Power: 2900W
- Maximum Efficiency: ≥ 92.5%
- Operating Temperature Range: -40°C ~ +75°C
- Cooling System: Forced Air Cooling with Intelligent Speed Fan
- Hot-Swappable Support: Yes (Live Hot-Pluggable / Plug-and-Play without Power Interruption)

## Frequently asked questions

### How do I select 4850C for my power system?

Check output voltage, module power rating, efficiency class and compatibility with your existing rectifier shelf or controller. RICEWIND can verify fitment and propose the right quantity.

### Is 4850C compatible with my existing system?

Compatibility depends on the rectifier shelf, controller and communication protocol. Send your current system model to RICEWIND and our engineers will confirm which modules fit.

### Does RICEWIND provide international shipping for 4850C?

Yes. Power modules and systems are packed in anti-static, export-standard crates and shipped worldwide. Delivery time and freight options depend on stock and destination — contact RICEWIND for quotes and lead times.

### What warranty and technical support apply to 4850C?

Warranty follows the manufacturer's policy for the specific equipment. RICEWIND supports testing guidance, replacement requests, spare parts and technical coordination per order terms.

### Does RICEWIND supply 4850C from stock?

Yes. RICEWIND supplies 4850C from verified stock with MOQ from 1 piece; in-stock units dispatch within 24-48 hours with global express air and sea freight.

### Is there a cross-reference or equivalent for 4850C?

RICEWIND maintains a comprehensive cross-reference chart covering Huawei, Vertiv (Emerson), Eltek, ZTE and Delta 48V telecom rectifiers. Contact us for the direct equivalent of 4850C.

### How does the DPC 4850C handle low AC input voltage conditions below 176V AC?

The module incorporates an automatic, linear power derating curve to protect internal semiconductors from thermal overload caused by elevated input currents. Between 176V AC and 290V AC, the module delivers full rated output (2900W / 50A). When input voltage falls between 90V AC and 176V AC, the output power linearly derates, delivering approximately 50% capacity at 90V AC, keeping loads operational and postponing battery depletion.

### What does a solid red fault LED on the front panel indicate, and how should it be reset?

A solid red LED indicates an internal latching shutdown, typically caused by output overvoltage protection (OVP), primary-side overcurrent, or persistent overtemperature lockout. To reset, disconnect the module from the AC source (or extract it from the live slot), verify the DC bus is clear of foreign short circuits, wait at least 3 minutes for internal bulk storage capacitors to discharge, and reinsert or power on the module.

### Why would one 4850C module in a multi-module shelf show an abnormal current discrepancy compared to adjacent units?

This is usually caused by an interrupted current-share bus signal, a loose blind-mate connector pin, or a disparity in baseline voltage calibration. Inspect the rear gold-finger backplane connector for dust, contamination, or mechanical pin damage. Ensure all rectifiers share identical parameter settings via the shelf controller, and confirm that the underperforming module is not operating in a thermal derating condition due to blocked airflow.

### Can the 4850C cooling fan be serviced in the field if it exhibits high-pitched bearing noise or stalls?

Yes, the 4850C cooling fan is field-serviceable. Because the fan speed is controlled intelligently based on internal heatsink thermistors, high speed can be normal under heavy load or dust contamination. However, if the fan has mechanical bearing wear or has seized, the front bezel assembly can be accessed after de-energizing and removing the module. Replace the assembly using only manufacturer-certified 4-wire PWM tachometer fans to maintain alarm loop integrity.

Content updated: 2026-09-17T01:31:48.105Z