# Delta ESR4856BC 96% Gold High-Efficiency Energy-Saving Telecom Rectifier Module (54V 56A 3000W)

RICEWIND · Delta

https://ricewind.com/en/products/delta-esr4856bc-b29

Model: ESR4856BC

The Delta ESR4856BC is a carrier-grade 3000W single-phase AC-to-DC telecom switch-mode rectifier module, delivering a nominal output of 54V DC (adjustable from 43V to 58V DC) and a maximum output current of 56A with peak energy efficiency exceeding 96.0%.

## What this product is

Architecturally, the ESR4856BC incorporates Digital Signal Processing (DSP) closed-loop control, a dual-stage bridgeless PFC stage, and an isolated resonant LLC DC-DC converter. It complies fully with IEC/EN 60950-1 safety standards and EN 55022 Class B telecom EMC profiles, leveraging an onboard CAN bus to feed real-time telemetry—including input/output dynamics, internal thermal metrics, and fault logs—to system controllers.

## What problem it solves

It mitigates common telecom site vulnerabilities including high mains surges, sustained brownouts, phase volatility, thermal de-rating failures, and high carbon footprints. By maintaining tight DC voltage regulation and high power factor (\>0.99), it prevents spurious battery cycling, deep-discharge degradation, and unscheduled site outages caused by power conversion failure.

## Who and where it is for

Tailored for 4G/5G mobile base transceiver stations, distributed antenna system (DAS) hubs, central office DC telecom power shelves, industrial automation racks, and hybrid off-grid telecom installations paired with solar and storage systems.

## Core advantages

- Ultra-high efficiency up to 96.0% with bridgeless APFC and resonant LLC topology, significantly lowering TCO.
- Wide input voltage range (80V AC to 300V AC) with 300V AC surge tolerance for harsh grid environments.
- Robust 3000W output (54V 56A) supporting live hot-swappable replacement and intelligent CAN bus telemetry.
- Intelligent fan cooling and hardware-level adaptive droop current limiting prevent base station downtime.

## Applications

- Primary DC power supply and battery float charging in outdoor 5G telecom cabinets
- N+1 redundant power shelf deployments in central telecommunication switching offices
- Continuous DC rail supply for railway signaling, SCADA systems, and transport control networks
- Hybrid renewable energy telecommunication sites combining photovoltaic arrays, gensets, and battery banks

## Technical specifications

- Maximum Output Current: 56A
- Rated Output Voltage: -48VDC (-42V ~ -58V)
- AC Input Voltage: 80V AC ~ 300V AC
- Rated Output Power: 3000W
- Maximum Efficiency: ≥ 96.0%
- Operating Temperature Range: -40°C ~ +75°C
- Cooling System: Forced Air Cooling with Intelligent Speed Fan
- Hot-Swappable Support: Yes (Live Hot-Pluggable / Plug-and-Play without Power Interruption)

## Frequently asked questions

### How do I select ESR4856BC for my power system?

Check output voltage, module power rating, efficiency class and compatibility with your existing rectifier shelf or controller. RICEWIND can verify fitment and propose the right quantity.

### Is ESR4856BC compatible with my existing system?

Compatibility depends on the rectifier shelf, controller and communication protocol. Send your current system model to RICEWIND and our engineers will confirm which modules fit.

### Does RICEWIND provide international shipping for ESR4856BC?

Yes. Power modules and systems are packed in anti-static, export-standard crates and shipped worldwide. Delivery time and freight options depend on stock and destination — contact RICEWIND for quotes and lead times.

### What warranty and technical support apply to ESR4856BC?

Warranty follows the manufacturer's policy for the specific equipment. RICEWIND supports testing guidance, replacement requests, spare parts and technical coordination per order terms.

### Does RICEWIND supply ESR4856BC from stock?

Yes. RICEWIND supplies ESR4856BC from verified stock with MOQ from 1 piece; in-stock units dispatch within 24-48 hours with global express air and sea freight.

### Is there a cross-reference or equivalent for ESR4856BC?

RICEWIND maintains a comprehensive cross-reference chart covering Huawei, Vertiv (Emerson), Eltek, ZTE and Delta 48V telecom rectifiers. Contact us for the direct equivalent of ESR4856BC.

### What is the primary cause if the ESR4856BC shows a solid red alarm LED and cuts DC output?

A continuous red LED signifies a critical lockout triggered by Output Over-Voltage Protection (OVP), utility over-voltage (\>300V AC), or Over-Temperature Protection (OTP). Isolate the module from AC input for 3 minutes to discharge DC link capacitors, then reconnect. If the fault persists, verify that the fan is spinning freely, inspect front grilles for thermal blockage, and confirm controller-set bus voltage limits.

### Does the ESR4856BC deliver full 3000W output under a low AC input of 110V/120V AC?

No. The module employs an intelligent input-dependent derating mechanism. Full 3000W output is guaranteed between 176V AC and 300V AC. When mains dip into the 80V AC to 176V AC bracket, internal control logic limits AC input current to protect the PFC stage, scaling output power linearly down to approximately 40%–50% of maximum rating.

### How is current sharing managed when multiple ESR4856BC modules operate in parallel?

The module utilizes active autonomous droop current sharing combined with continuous CAN bus digital trimming orchestrated by the supervisory controller (e.g., Delta CSU series). Between 50% and 100% load conditions, current sharing imbalance between modules is strictly kept within ±5%, eliminating the need for manual calibration.

### What specific handling is required during live hot-swapping in an energized telecom shelf?

Verify that connector pins on the module rear and shelf backplane are clean and mechanically straight. Slide the module into the guide rails firmly in a single continuous stroke until the primary ground-first pin engages, followed by the high-current DC and AC blades. Secure the mechanical latch; the module executes an internal self-test, charges the bus softly, and resumes normal supply within 3 to 5 seconds.

Content updated: 2026-09-16T11:25:58.810Z