# Delta ESR-48/60 AA Telecom Rectifier Module 54V 3000W

RICEWIND · Delta

https://ricewind.com/en/products/delta-esr-48-60-aa-b28

Model: ESR-48/60 AA

The Delta ESR-48/60 AA is an industrial-grade, high-power-density telecom switch-mode rectifier module rated for a nominal output of 48V/54V DC, 60A continuous load current, and up to 3200W output power. Engineered for mission-critical telecommunications infrastructure, it converts unstable, wide-range AC utility power into clean, tightly regulated DC power for active telecom loads and precision battery bank charging.

## What this product is

The ESR-48/60 AA comprises an active power factor correction (PFC) boost pre-stage, an LLC resonant high-frequency DC-DC isolation stage, and a redundant dual-MCU control board. The AC mains passes through multi-stage common-mode and differential-mode EMI filtering before the PFC stage corrects the power factor to \>0.99 and stabilizes the internal high-voltage DC bus. The resonant LLC stage guarantees zero-voltage switching (ZVS) on primary-side MOSFETs and zero-current switching (ZCS) on synchronous rectifiers, yielding low EMI and minimal switching losses. A high-durability blind-mate backplane connector integrates AC input, DC output bus, and CAN/RS485 telemetry into a compact, hot-swappable form factor.

## What problem it solves

It eliminates unexpected site downtime triggered by severe utility voltage sags, brownouts, and surges in unstable rural or industrial grid zones. Its superior \>96% thermodynamic efficiency mitigates thermal congestion in tightly packed telecom shelters, cutting air conditioning power demands. Furthermore, its true live-plug capability and fully autonomous dynamic current-sharing architecture eradicate single-point-of-failure risks, enabling rapid capacity scaling and seamless field servicing without disrupting active telecom payloads.

## Who and where it is for

Ideal for 4G/5G macro cell outdoor cabinets, enterprise edge datacenters, central office transmission nodes, utility substation DC tripping systems, and railway trackside signaling power supplies.

## Core advantages

- Ultra-high conversion efficiency exceeding 96%, minimizing cabinet heat loads and cooling OPEX
- Wide AC input voltage envelope (85Vac to 300Vac) for rugged tolerance against grid instability
- Full hot-swap compatibility with autonomous dynamic current sharing for zero-downtime scalability
- Dual-MCU digital regulation offering sub-millisecond dynamic response and complete hardware protections

## Applications

- 5G and LTE macro base station indoor and outdoor power distribution enclosures
- Edge computing micro-datacenters and central office telecom power racks
- Electrified railway wayside signaling and mission-critical communications shelters
- Industrial automated substations and smart grid switchgear auxiliary DC power plants

## Technical specifications

- Power density: Power Density: 56.8 W/in³
- Overall System Efficiency: 整机综合转换效率: 96.4 %
- Rated output power: 额定输出功率: 3000 W
- Hot-Swap Mechanical Protection: 带电热插拔与机械防护: Yes
- AC input voltage range: 交流输入电压: 90 to 300 VAC
- Cooling Method: 散热冷却方式: Fan cooled with speed control
- Operating Temperature Range: 工作环境温度范围: -40 to +75 ℃
- Rated system voltage: Rated System Voltage: 54.0 VDC
- Rectifier model: Rectifier Model: DPR 3000B-48
- Operating Voltage Range: Operating Voltage Range: 43 to 58 VDC
- Dimensions: 物理结构外形尺寸: 84.0 x 41.0 x 265.0 mm
- Current Limit: Current Limit: 59.0 A
- AC Input Frequency: AC Input Frequency: 50 / 60 Hz
- Internal Fuse Quantity: Internal Fuse Quantity: 2
- Internal Fuse Rated Current: Internal Fuse Rated Current: 20 A
- Control and Monitoring System: Control and Monitoring System: ORION Touch
- Weight: Weight: 1.3 kg
- IP Protection Rating: IP Protection Rating: IP20 (EN 60529)

## Frequently asked questions

### How do I select ESR-48/60 AA for my power system?

Check output voltage, module power rating, efficiency class and compatibility with your existing rectifier shelf or controller. RICEWIND can verify fitment and propose the right quantity.

### Is ESR-48/60 AA compatible with my existing system?

Compatibility depends on the rectifier shelf, controller and communication protocol. Send your current system model to RICEWIND and our engineers will confirm which modules fit.

### Does RICEWIND provide international shipping for ESR-48/60 AA?

Yes. Power modules and systems are packed in anti-static, export-standard crates and shipped worldwide. Delivery time and freight options depend on stock and destination — contact RICEWIND for quotes and lead times.

### What warranty and technical support apply to ESR-48/60 AA?

Warranty follows the manufacturer's policy for the specific equipment. RICEWIND supports testing guidance, replacement requests, spare parts and technical coordination per order terms.

### Does RICEWIND supply ESR-48/60 AA from stock?

Yes. RICEWIND supplies ESR-48/60 AA from verified stock with MOQ from 1 piece; in-stock units dispatch within 24-48 hours with global express air and sea freight.

### Is there a cross-reference or equivalent for ESR-48/60 AA?

RICEWIND maintains a comprehensive cross-reference chart covering Huawei, Vertiv (Emerson), Eltek, ZTE and Delta 48V telecom rectifiers. Contact us for the direct equivalent of ESR-48/60 AA.

### What is the proper hot-swap procedure for replacing an operational ESR-48/60 AA module?

Inspect the replacement unit to ensure physical integrity and clean blind-mate pins. Unlatch the front mechanical ejector handle of the target module; this mechanical action disengages the primary retention lock and signals the internal MCU to ramp down switching. Pull the module smoothly out along the chassis guide rails. Align the replacement module within the same slot and slide it firmly inward until the backplane connector fully engages and the latch clicks shut. The central controller automatically provisions the module via the bus, executing a soft-start and autonomously balancing the DC load within seconds without dropping the system bus.

### How is the rectifier module integrated into central DCIM, SNMP, or RS485 communication systems?

The module interfaces with the shelf backplane through an integrated high-speed CAN/RS485 bus that routes directly into the shelf controller (such as the Delta CSU series). The controller aggregates real-time telemetry—including phase voltages, output current, heatsink temperature, and diagnostic fault registers—and exposes these metrics to DCIM and SCADA systems via onboard Ethernet using SNMPv3, Modbus-TCP, or RESTful API endpoints.

### How do the output over-voltage (OVP) and over-temperature (OTP) protection mechanisms operate?

If the DC bus output exceeds the factory hardware limit (typically 59.5V ± 0.5V), an independent hardware crowbar/latch circuit immediately inhibits the PWM drive pulses within microseconds, locking out the module to safeguard connected telecommunication gear; an AC cycle reset or controller command is required to clear this state. For thermal stress, the internal MCU tracks critical component thermistors: as temperature approaches maximum limits (approx. 95°C heatsink), the module linearly throttles output power, shutting down entirely if the critical threshold is surpassed and automatically restarting once thermal hysteresis conditions are satisfied.

### What preventative maintenance schedule and inspection items are recommended for this module?

Every 6 to 12 months, perform the following preventative checks: 1. Clean front air intakes and use clean, dry compressed air to clear internal dust buildup from the cooling tunnel and heatsink fins; 2. Verify unobstructed rotation and absence of acoustic anomalies from the integrated brushless DC fan; 3. Inspect rear blind-mate power pins for signs of fretting corrosion, pitting, or thermal discoloration; 4. Cross-reference controller telemetry against a calibrated true-RMS multimeter to confirm voltage and current measurement accuracy.

Content updated: 2026-09-16T10:14:55.153Z