# CE+T 25kVA Modular Inverter Subrack (19-Inch Rackmount 48V/60Vdc to 230V/400Vac TSI/Bravo)

RICEWIND · Ce+T

https://ricewind.com/en/products/cet-25kva-inverter-shelf

Model: CE+T 25kVA Modular Inverter Subrack

The CE+T 25kVA Modular Inverter Subrack is a 19-inch heavy-duty chassis system engineered for mission-critical telecom and industrial AC power security. Designed to house parallel TSI or Bravo inverter modules, it interfaces with 48V/60V telecom battery buses and AC grid feeds, leveraging patented bidirectional power conversion to deliver zero-transfer pure sine wave power with built-in static bypass.

## What this product is

The CE+T 25kVA Modular Inverter Subrack is a 19-inch heavy-duty chassis system engineered for mission-critical telecom and industrial AC power security. Designed to house parallel TSI or Bravo inverter modules, it interfaces with 48V/60V telecom battery buses and AC grid feeds, leveraging patented bidirectional power conversion to deliver zero-transfer pure sine wave power with built-in static bypass.

## What problem it solves

The CE+T 25kVA Modular Inverter Subrack delivers carrier-class AC/DC power integration for demanding infrastructure. Designed with versatile topology, it natively supports single-phase 230Vac or three-phase 400Vac pure sine wave outputs, fulfilling international industrial grid codes and telecom power distribution standards.

\[Core Power Architecture\]
Featuring CE+T patented TSI (Twin Sine-wave Inverter) technology, the system manages bidirectional power flow between AC-AC and DC-AC channels. During mains voltage sags or total blackout, the subrack switches to the 48V/60V DC battery bank in true zero milliseconds (0ms), fully isolating mission-critical IT and industrial equipment from upstream voltage transients.

\[Hot-Swappable Redundancy & Electrical Safeguards\]
The backplane architecture provides isolated power and signaling paths for each slot, enabling hot-swap replacement and true N+1/N+X modular redundancy without disrupting connected loads. The subrack integrates a dual-tier protection matrix featuring an electronic static bypass switch (STS) alongside a mechanically interlocked manual maintenance bypass.

\[Field Reliability & Network Telemetry\]
Built to comply with harsh telecom EMC/RFI standards, the system relies on an internal high-speed CAN bus for ultra-low latency module synchronization. Through intelligent centralized monitoring modules, it exposes standard SNMP, Modbus RTU/TCP, and secure HTTP interfaces for remote supervisory control from -20°C to +50°C.

## Who and where it is for

The CE+T 25kVA Modular Inverter Subrack is a 19-inch heavy-duty chassis system engineered for mission-critical telecom and industrial AC power security. Designed to house parallel TSI or Bravo inverter modules, it interfaces with 48V/60V telecom battery buses and AC grid feeds, leveraging patented bidirectional power conversion to deliver zero-transfer pure sine wave power with built-in static bypass.

## Core advantages

- Patented TSI topology enables true 0ms transfer across AC and DC paths
- Standard 19-inch rugged chassis supporting live hot-swap expansion
- Compatible with 48V/60V DC bus for clean single/three-phase AC outputs
- Integrated dual bypass with ultra-fast static switch and manual bypass
- Modular N+1 resilient architecture rated for continuous 20kW loads
- CAN bus inter-module coordination with SNMP and Modbus remote telemetry

## Applications

- Central telecom switching offices and wireless basestation AC backup
- Railway trackside signaling centers and transit SCADA electrical feeds
- Power substation DC-to-AC power supply cabinets and automation nodes
- Offshore oil & gas automation, marine navigation, and DCS controllers
- Edge computing facilities and modular data center communications racks
- Industrial microgrids and critical automated manufacturing facilities

## Technical specifications

- System Output Capacity: 25kVA / 20kW modular three-phase / single-phase inverter subrack
- DC Input Voltage: 48V DC / 60V DC telecom DC battery bus input
- Physical Form Factor: 19-Inch Rackmount
- Inverter Module Slots: hot-swappable parallel operation of multiple Bravo or TSI inverter modules
- Rated AC Output Voltage: -48VDC (-42V ~ -58V)
- TSI Core Technology: CE+T patented TSI bidirectional power conversion (0 ms seamless transfer between AC mains and battery)
- Bypass Protection System: Built-in dual protection with electronic static bypass and manual maintenance bypass
- Operating Temperature Range: -20°C to +50°C

## Frequently asked questions

### How do I choose the right CE+T 25kVA Modular Inverter Subrack for my system?

Verify host model, electrical ratings, interface types and protocol requirements. Share your system details with RICEWIND and we will compare compatible options across brands.

### Is CE+T 25kVA Modular Inverter Subrack compatible with my existing equipment?

Compatibility depends on power input, pinout signals and rack mounting specifications. Our engineers can review interfaces and integration details before you order.

### Does RICEWIND provide international shipping for CE+T 25kVA Modular Inverter Subrack?

Yes. RICEWIND ships worldwide; freight options depend on destination, weight and urgency. Contact us for a shipping quote to your site.

### What warranty and after-sales support are available for CE+T 25kVA Modular Inverter Subrack?

Warranty follows the manufacturer policy for your region. RICEWIND provides technical documentation, firmware guidance and engineer-level assistance throughout the project.

### Does RICEWIND supply CE+T 25kVA Modular Inverter Subrack?

Yes. RICEWIND supplies CE+T 25kVA Modular Inverter Subrack with MOQ from 1 unit; in-stock items dispatch within 24-48 hours with worldwide shipping.

### Is there a cross-reference or equivalent for CE+T 25kVA Modular Inverter Subrack?

RICEWIND maintains a cross-reference database covering leading telecom and energy infrastructure brands. Contact us for the direct equivalent of CE+T 25kVA Modular Inverter Subrack.

### What are the core rated capacity, power factor, and conversion efficiency metrics of this CE+T 25kVA subrack?

The subrack delivers a maximum configured output of 25kVA / 20kW with an operating power factor range from 0.8 leading to 0.8 lagging (up to 1.0 for resistive loads). In AC-AC mode, total conversion efficiency exceeds 96%, while in DC-AC inverter mode it exceeds 93.5%, delivering a flat efficiency curve that substantially reduces facility thermal dissipation.

### What is the physical form factor of the unit, and how is it integrated into standard racks with adequate cooling?

The unit features a heavy-duty 19-inch rackmount chassis, occupying 4U to 6U depending on the internal bypass configuration, with a depth designed for standard 600mm+ telecom cabinets. Cooling follows a front-to-rear linear forced airflow architecture, where each individual module employs independent variable-speed fans to prevent backdrafting in high-density stacks.

### What surge suppression and overload tolerance mechanisms protect this subrack against harsh industrial grid environments?

The subrack integrates Class II surge protection devices (compliant with IEC 61643-11) on its AC inputs to suppress high-voltage transients. It features robust overload resilience: 150% rated load for 15 seconds and 125% for 60 seconds. Under downstream fault conditions, it delivers high short-circuit clearing currents to trip local breakers without destabilizing the AC bus.

### How does the subrack operate with 48V/60V batteries, and is there any transfer interruption between AC mains and DC bus?

The DC busbars are engineered for standard 48V/60V VRLA and LiFePO4 telecom battery plants, supporting wide voltage windows and external LVD integration. Because of the patented TSI architecture, the AC grid feed and DC battery bus remain continuously coupled via high-frequency resonance, achieving absolute zero-millisecond (0ms) transfer time during power outages.

Content updated: 2026-09-13T09:50:28.839Z