# Compact Outdoor Telecom Cabinet Industrial Air Conditioner AC 600W (Compact Outdoor Side/Door Mount IP55)

RICEWIND · Ricewind

https://ricewind.com/en/products/cabinet-ac-600w

Model: Cabinet AC 600W

The Cabinet AC 600W is a lightweight compact industrial enclosure air conditioner delivering 600W of refrigeration with IP55 closed-loop internal isolation for small outdoor electrical and telecom junction boxes.

## What this product is

Compact external mount industrial cooling unit for small enclosures.

## What problem it solves

Delivers reliable closed-loop cooling for small form-factor outdoor boxes where standard cabinet AC units cannot physically fit.

## Who and where it is for

Outdoor security camera junction boxes, traffic signal consoles, solar charge enclosures, and pole-mount cabinets.

## Core advantages

- Ultra-compact footprint fits space-restricted cabinet panels
- Complete internal IP55 dust and moisture isolation loop
- Low power consumption with high-efficiency miniature rotary compressor
- Digital temperature controller with alarm dry contact relays

## Applications

- Hyperscale and enterprise cloud data center high-density server halls and aisle containment
- Telecommunications switching centers, optical transmission rooms, and carrier core facilities
- High-reliability industrial test laboratories and clean room production environments
- Rail transit command signaling centers and electrical power grid dispatch operations

## Technical specifications

- Rated Cooling Capacity: 600 W
- Grid Power Supply System: 380V 3-Phase / 220V 1-Phase Compatible VAC
- Rated Input Power: 280 W
- Max Operating Current: 1.6 A
- Refrigerant Type: R134a Eco Refrigerant
- Ingress Protection (IP Rating): Internal Loop IP55 / External Loop IP34 (Sealed Dust & Water Proof)
- Internal Airflow Volume: 150 m³/h
- Operating Temperature Range: -20 ~ +55°C
- Operating Noise Level: ≤ 55 dB(A)
- Physical Dimensions: 580 × 310 × 170 mm
- Net Weight: 16.5 kg
- Installation / Mounting Mode: Outdoor Cabinet External (Door-Mounted / Side Wall-Mounted)
- Communication Interface: RS485 (Standard Modbus-RTU) + Dry Contact Alarm

## Frequently asked questions

### How do I choose the right Cabinet AC 600W for my site?

Consider total sensible heat load, airflow configuration (upflow/downflow), ambient temperature limits, piping elevation and monitoring needs. Share your requirements with RICEWIND and we will compare suitable models from multiple brands for you.

### Is Cabinet AC 600W compatible with my existing infrastructure?

Compatibility depends on power supply, refrigerant pipe dimensions and environmental monitoring protocols (RS-485/Modbus/SNMP). Our engineers can verify pipe sizing, wiring and BMS integration before you order.

### Does RICEWIND provide international shipping for Cabinet AC 600W?

Yes. Indoor and outdoor units are shipped globally with reinforced non-coniferous export wooden crates and nitrogen holding pressure. Freight options depend on destination port and urgency — contact us for a shipping quote.

### What warranty and technical support are available for Cabinet AC 600W?

Warranty follows the manufacturer policy for your region. RICEWIND provides installation drawings, commissioning documentation, OEM spare parts and engineer-level technical assistance throughout the project.

### Does RICEWIND supply Cabinet AC 600W?

Yes. RICEWIND supplies Cabinet AC 600W from verified inventory, MOQ from 1 unit; in-stock units dispatch within 24-48 hours with worldwide shipping.

### Is there a cross-reference or equivalent for Cabinet AC 600W?

RICEWIND maintains a cross-reference database covering Vertiv (Liebert), Envicool, and Huawei thermal management systems. Contact us for direct equivalents or retrofit recommendations for Cabinet AC 600W.

### How does the 600W compact door-mounted AC ensure structural compatibility and telemetry integration in outdoor enclosures?

Featuring an ultra-compact door/side-mount mechanical form factor, the ENCLOSURE-AC-600W utilizes standardized flange cutout dimensions compatible with mainstream micro-BTS, outdoor BBU, and edge battery/power cabinets. For integration, it is equipped with dry contact alarm outputs for high temperature and compressor fault monitoring, with optional RS485 (Modbus-RTU) expansion for seamless integration into local Field Supervision Units (FSU) and centralized OSS/EMS, enabling remote temperature setpoint adjustments, power telemetry, and status polling.

### How does the ENCLOSURE-AC-600W maintain airtight reliability and thermal stability under extreme ambient conditions from -20°C to +55°C?

The unit employs a dual-loop isolated aerodynamic architecture: the internal cycle features an IP55 ingress protection rating to completely seal the cabinet from ambient moisture, dust, and corrosive airborne contaminants, while the external cycle maintains IP34 protection with hydrophilic aluminum fins and anti-corrosion coating. Rated for harsh operating temperatures from -20°C to +55°C, the system integrates compressor soft-start, thermal discharge protection, and an autonomous condensate management circuit, ensuring carrier-grade reliability with an MTBF exceeding 100,000 operating hours.

### What are the interface definitions, wiring specifications, and communication networking for the Cabinet AC 600W (SKU: ENCLOSURE-AC-600W) in temperature control and monitoring systems?

According to the official system manual, the Cabinet with Cooling System (CCS) collaborates with the Integrated Controller and Converter (ICC) and monitoring units (e.g., CPMU01/SCC800-C1): 1. Power Supply Interfaces: The cabinet infrastructure supports AC Input (AC) with three-phase four-wire, dual-live wire, or single-phase configurations, as well as DC Input (DC) connected to Energy Storage Subsystems (ESS) such as ESM-48100/ESM-48150 lithium batteries. 2. Sensor and Communication Pinouts: Supports connections for digital temperature and humidity sensors, smoke sensors, water sensors, communication extension modules (NIM01C3), and signal surge protectors (SPM01A). 3. Networking and Autonomous Operation: The ICC monitoring unit handles logic scheduling and status reporting to the NetEco Operations Support System (OSS). In offline or maintenance scenarios, hot-swap/replacement of the monitoring unit is supported without disconnecting AC input or DC output (keeping loads powered), ensuring continuous thermal protection and system stability.