# Eltek 252189 Subrack Telecom DC Power System (-48V 4-Slot Flatpack2)

RICEWIND · Eltek

https://ricewind.com/en/products/252189-subrack-power-system

Model: 252189 Subrack Power System

The Eltek 252189 is an embedded 19-inch 2U subrack DC power system engineered for telecom and core networking, integrating Flatpack2 rectifier slots, Smartpack controller interface, and integrated AC/DC distribution.

## What this product is

The Eltek 252189 is a rack-mountable DC power distribution and conversion chassis equipped with high-efficiency switch-mode rectifier positions, a CAN bus architecture, and load/battery disconnect contactors designed to deliver uninterrupted -48V power.

## What problem it solves

Eliminates power density bottlenecks in space-constrained telecom enclosures, mitigates system downtime via modular N+1 redundancy, and prevents destructive battery deep-discharge through programmable disconnection thresholds.

## Who and where it is for

Wireless base stations, BBU pooling hubs, optical access nodes, enterprise telecom racks, and edge computing installations requiring reliable DC backup power.

## Core advantages

- Ultra-compact 2U 19-inch form factor delivering up to 8kW/150A continuous DC output to optimize rack footprint.
- Engineered for high-efficiency Flatpack2 rectifiers achieving system efficiency ≥96%, cutting thermal losses and operating expenditure.
- Integrated dual Low Voltage Disconnects (LLVD and BLVD) for critical load prioritization and battery preservation.
- Robust CAN bus communication enabling automatic active current sharing and seamless Smartpack monitoring.

## Applications

- 4G/5G mobile telecom base transceiver stations (BTS) and BBU hotels
- Fixed-line broadband optical central offices and FTTx aggregation sites
- Industrial SCADA, railway signaling, and utility substations requiring -48VDC
- Edge data center transmission routers and networking switches

## Technical specifications

- Cooling System Architecture: Independent module air cooling & rack straight duct
- Smart Monitoring Controller: Smartpack2 / Smartpack S Controller Slot
- AC Input Voltage: 85VAC ~ 300VAC (Nominal 220V/380VAC) VAC
- Nominal Output Voltage: -48VDC (-42V ~ -58V) VDC
- Managed Rectifier Capacity: 4 × Flatpack2 48/2000 HE / 48/3000 HE Slots
- Rated DC Output Current: 200A (Subrack Capacity 11.6kW)
- Form Factor Dimensions (HxWxD): 88 (2U) × 482 × 330 mm
- Peak Energy Efficiency: ≥96.5%
- Operating Temperature Range: -40°C ~ +65°C

## Frequently asked questions

### How do I select 252189 Subrack Power System for my power system?

Check output voltage, module power rating, efficiency class and compatibility with your existing rectifier shelf or controller. RICEWIND can verify fitment and propose the right quantity.

### Is 252189 Subrack Power System compatible with my existing system?

Compatibility depends on the rectifier shelf, controller and communication protocol. Send your current system model to RICEWIND and our engineers will confirm which modules fit.

### Does RICEWIND provide international shipping for 252189 Subrack Power System?

Yes. Power modules and systems are packed in anti-static, export-standard crates and shipped worldwide. Delivery time and freight options depend on stock and destination — contact RICEWIND for quotes and lead times.

### What warranty and technical support apply to 252189 Subrack Power System?

Warranty follows the manufacturer's policy for the specific equipment. RICEWIND supports testing guidance, replacement requests, spare parts and technical coordination per order terms.

### Does RICEWIND supply 252189 Subrack Power System from stock?

Yes. RICEWIND supplies 252189 Subrack Power System from verified stock with MOQ from 1 piece; in-stock units dispatch within 24-48 hours with global express air and sea freight.

### Is there a cross-reference or equivalent for 252189 Subrack Power System?

RICEWIND maintains a comprehensive cross-reference chart covering Huawei, Vertiv (Emerson), Eltek, ZTE and Delta 48V telecom rectifiers. Contact us for the direct equivalent of 252189 Subrack Power System.

### How are DC bus output cable cross-sections and loop voltage drops calculated for the 252189 subrack?

DC cable sizing must be derived from the continuous maximum load current (e.g., 150A) and the maximum permissible round-trip loop voltage drop (typically ΔV ≤ 0.5V for telecom standards). The formula is S = (2 \* L \* I) / (γ \* ΔV), where L is the single-run route distance in meters, I is maximum circuit current in amperes, γ is copper conductivity (~57 m/(Ω·mm²)), and ΔV is allowable drop. The conductor ampacity must also satisfy local thermal rise limits under ambient temperature derating.

### What are the recommended voltage setpoints for LLVD and BLVD thresholds in this DC system?

For a standard 48V VRLA battery string (24 cells): LLVD (Load Low Voltage Disconnect, shedding non-critical loads) is typically set between 44.0VDC and 44.5VDC (~1.83V to 1.85V/cell) to maximize runtime for critical transmission. BLVD (Battery Low Voltage Disconnect) is configured at 43.0VDC to 43.2VDC (~1.79V to 1.80V/cell), where all remaining loads and batteries are completely disconnected to prevent catastrophic cell reversal and permanent deep-discharge damage.

### How should the battery temperature compensation coefficient and reference temperature be configured in the Smartpack controller?

Under the Smartpack 'Battery Setup' menu: Define the reference temperature to match the battery manufacturer datasheet (typically 20°C for IEC/European standards or 25°C for standard IEEE). Set the negative temperature coefficient typically between -3.0 mV/°C/cell and -3.6 mV/°C/cell (equaling -72 mV/°C to -86.4 mV/°C for a 24-cell 48V string). Always enable upper and lower clamping limits (e.g., maximum float 56.4V, minimum 51.5V) to protect against excessive gassing at cold temperatures or severe undercharging in high ambient heat.

### How do Flatpack2 rectifiers achieve active parallel current sharing via CAN bus, and how is significant current imbalance diagnosed?

Flatpack2 modules broadcast real-time output current and telemetry via the backplane CAN bus. The Smartpack controller calculates average cluster current and transmits micro-voltage trimming commands to each rectifier's internal DSP, maintaining active current sharing within \<±5%. If severe current deviation occurs: 1) Verify physical integrity of CAN ribbon cabling and check for correct 120Ω bus termination; 2) Confirm that firmware revisions and voltage setpoint profiles match across all modules; 3) Reseat the offending rectifier and inspect the backplane blind-mate connector for fretting corrosion or bent pins.