Delta ESR-48/56BC Wide-Temperature Telecom Switch-Mode Rectifier Module (-48V 56A 3000W)
Deltaالطراز: ESR-48/56BC

Delta ESR-48/56BC Wide-Temperature Telecom Switch-Mode Rectifier Module (-48V 56A 3000W)

The Delta ESR-48/56BC is a ruggedized 48V 56A high-reliability telecom switch-mode rectifier module rated at 3000W, engineered for extreme temperatures and featuring enhanced surge immunity.

يتم تأكيد الأسعار وفقاً لتهيئة المشروع والكميات المطلوبة

طلب عرض أسعار
Nominal Output Voltage
-48V DC (Adjustable: -42V to -58V)
Rated Output Current
56A Continuous Output
Rated Output Power
3000W
AC Input Range
85V to 300V AC (Nominal 220VAC)
Operating Temperature Range
-40°C to +75°C (Full load to 55°C)
Protection & Mounting
6kV Surge Immunity / Hot-Swap

نظرة عامة على المنتج

نظرة عامة على المنتج

This unit is primarily deployed within Delta outdoor enclosures and indoor telecom power racks, providing high-purity -48V DC power with superior lightning surge immunity.

المشكلات التي يعالجها

Solves outdoor base station vulnerabilities such as extreme ambient heat and grid lightning surges causing premature rectifier failure, ensuring high uptime for unattended sites.

الفئات المستهدفة وبيئات الاستخدام

Engineered for 4G/5G outdoor integrated cabinets, remote border station towers, highway surveillance power systems, and utility substation communications.

المزايا الجوهرية

  • Extreme Temperature Tolerance: Operates reliably from -40°C to +75°C, sustaining 100% full rated power up to 55°C ambient.
  • Enhanced Lightning Surge Immunity: Integrated multi-stage surge protection circuit withstands up to 6kV common and differential mode transients.
  • Advanced Digital DSP Control: Embedded DSP delivers precise autonomous load-sharing, sub-millisecond dynamic response, and low THD.
  • High Power Density Compact Footprint: Optimizes subrack space, maximizing room for backup batteries and transmission hardware.

المواصفات الفنية

المواصفات الرئيسيةالقيمة
Nominal Output Voltage-48V DC (Adjustable: -42V to -58V)
Rated Output Current56A Continuous Output
Rated Output Power3000W
AC Input Range85V to 300V AC (Nominal 220VAC)
Operating Temperature Range-40°C to +75°C (Full load to 55°C)
Protection & Mounting6kV Surge Immunity / Hot-Swap

التطبيقات

01

4G/5G Telecom Cell Sites & Distributed Power Systems

02

Carrier Core Network Facilities & IDC DC Plants

03

Industrial Automation & Utility Substation DC UPS

الأسئلة الشائعة

متابعة الاستكشاف

Delta