Delta ESR-48/50DE Ultra-High Efficiency Telecom Switch-Mode Rectifier Module (-48V 50A >96% Efficiency)
Deltaالطراز: ESR-48/50DE

Delta ESR-48/50DE Ultra-High Efficiency Telecom Switch-Mode Rectifier Module (-48V 50A >96% Efficiency)

The Delta ESR-48/50DE is a green energy-saving telecom rectifier module achieving over 96% peak conversion efficiency, delivering -48V 50A (up to 2900W) with digital resonant soft-switching technology.

يتم تأكيد الأسعار وفقاً لتهيئة المشروع والكميات المطلوبة

طلب عرض أسعار
Nominal Output Voltage
-48V DC (Range: -42V to -58V)
Rated Output Current
50A
Peak Conversion Efficiency
>96.2% Ultra-High Efficiency
AC Input Range
85V to 300V AC (Nominal 220V/230V)
Input Power Factor
>0.99 (Rated full load)
Cooling & Form Factor
Variable-Speed Fan / Subrack Hot-Swap

نظرة عامة على المنتج

نظرة عامة على المنتج

As the core energy engine of Delta modern telecom power systems, this module converts AC power into telecom-grade stabilized DC, cutting conversion power losses by over 50%.

المشكلات التي يعالجها

Helps telecom operators and data centers lower PUE, significantly cuts waste heat generation to reduce cooling overhead, and lowers total cost of ownership (TCO).

الفئات المستهدفة وبيئات الاستخدام

Widely deployed in green 5G cell sites, edge micro data centers, central office energy retrofits, and high-density telecom power racks.

المزايا الجوهرية

  • Industry-Leading Peak Efficiency: Peak efficiency exceeds 96.2%, meeting top-tier global green energy standards and minimizing heat dissipation.
  • Smart Multi-Unit Hibernation: Supports intelligent supervisory sleep cycling to keep active rectifiers operating at peak efficiency points.
  • High PF and Low Harmonics: Power factor >0.99 and THD <5%, preventing harmonic pollution to upstream transformers and generators.
  • Effortless Hot-Swap Capability: Standard guide-rail mechanism enables single-technician replacement within 10 seconds without site downtime.

المواصفات الفنية

المواصفات الرئيسيةالقيمة
Nominal Output Voltage-48V DC (Range: -42V to -58V)
Rated Output Current50A
AC Input Range85V to 300V AC (Nominal 220V/230V)
Input Power Factor>0.99 (Rated full load)
Cooling & Form FactorVariable-Speed Fan / Subrack Hot-Swap
Peak Conversion Efficiency>96.2% Ultra-High Efficiency

التطبيقات

01

4G/5G Telecom Cell Sites & Distributed Power Systems

02

Carrier Core Network Facilities & IDC DC Plants

03

Industrial Automation & Utility Substation DC UPS

الأسئلة الشائعة